NXP Semiconductors MP3V5004GC6U
- Part No.:
- MP3V5004GC6U
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 8-SMD, Gull Wing, Top Port
- Datasheet:
-
MP3V5004GC6U.pdf
- Description:
- SENSOR 0.57PSIG 0.13" 3V 8SOP
- Quantity:
- Payment:

- Shipping:

Inventory:1,462
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MP3V5004GC6U from Freescale Semiconductor is a monolithic silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and factory calibration. It delivers a ratiometric 0.6–3.0 V analog output over a 0–3.92 kPa (0–400 mm H₂O) gauge pressure range, operates from 2.7–3.3 V supply, draws ≤10 mA, and is housed in a thermoplastic (PPS) small-outline package (Case 482A) with dual port configuration.
For engineers reviewing the MP3V5004GC6U datasheet, MP3V5004GC6U pinout, MP3V5004GC6U application, or MP3V5004GC6U equivalent, this sensor is selected for microcontroller-based liquid-level sensing where low-pressure resolution, stable offset (0.45–0.75 V), ±1.5% VFSS accuracy at 0–100 mm H₂O, and 10°C to 60°C compensated operation are critical design requirements.
Technical Context
The MP3V5004GC6U integrates a shear-stress strain gauge, thin-film temperature compensation network, and two-stage gain/offset correction circuitry onto a single die. Its transfer function is VOUT = VS × [(0.2 × P) + 0.2] ± 2.5% VFSS, with ratiometric behavior tied directly to supply voltage (VS = 3.0 V ± 0.3 V).
It uses differential sensing with isolated P1 (pressure) and P2 (vacuum) ports, fluorosilicone gel die coating for environmental protection, and requires no external zeroing-though auto-zeroing is supported via host firmware per AN1636. Pins 1, 5, 6, 7, and 8 are NC, confirming internal signal routing and eliminating external bias or reference components.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–3.92 kPa (0–400 mm H₂O) gauge - defines full-scale input for washing machine water level detection and similar low-differential applications. |
| Output Voltage | 0.6–3.0 V ratiometric - scales linearly with supply voltage; eliminates need for separate voltage reference in MCU ADC interfacing. |
| Supply Voltage | 2.7–3.3 V DC - compatible with standard 3.3 V embedded systems without regulation overhead. |
| Supply Current | ≤10 mA - enables direct connection to low-power microcontroller GPIO or LDO outputs without heatsinking. |
| Offset Voltage | 0.45–0.75 V at 0 kPa - provides usable headroom above ground for single-supply ADCs and simplifies offset nulling. |
| Accuracy | ±1.5% VFSS (0–100 mm H₂O, 10–60°C) - ensures reliable threshold detection in consumer appliance control loops. |
| Sensitivity | 0.6 V/kPa (600 mV/kPa) - yields ~2.4 mV/mm H₂O resolution, supporting sub-10 mm H₂O level discrimination. |
Pinout & Package
MP3V5004GC6U is housed in a Small Outline Package (Case 482A), measuring 12.70 mm × 10.79 mm × 2.54 mm (L × W × H), with thermoplastic (PPS) body and stainless steel cap for port integrity. The package features dual pressure ports (P1/P2) and an 8-pin lead frame with exposed thermal pad (not electrically connected).
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Pin 1 | No Connect | Internally unconnected; must be left floating or grounded per layout guidelines to avoid mechanical stress coupling. |
| Pin 2 | VOUT | Analog output node delivering conditioned, temperature-compensated voltage proportional to applied pressure. |
| Pin 3 | GND | Ground reference for signal chain and supply return; requires low-impedance connection to minimize noise and offset drift. |
| Pin 4 | VS | Supply input (2.7–3.3 V); ratiometric output scaling means ADC reference can share this rail for simplified BOM. |
| Pins 5–8 | No Connect | All internally unused; PCB pads may be omitted or grounded for mechanical stability-no electrical function. |
Key Features
| Feature | Design Value |
|---|---|
| On-chip temperature compensation | Stabilizes offset and span across 10°C to 60°C operating range-eliminates need for external thermistor or software lookup tables. |
| Dual-port gauge configuration | Enables differential pressure measurement with P1 side identified by port attachment-supports sealed or vented reference designs. |
| Fluorosilicone gel isolation | Protects wire bonds and die surface from moisture and particulates while transmitting pressure-extends reliability in humid appliance environments. |
| Ratiometric output architecture | Output scales with supply voltage; allows use of same 3.3 V rail for both sensor excitation and ADC reference-reduces component count and layout complexity. |
| Factory calibration and auto-zero support | Delivers ±1.5% VFSS accuracy out-of-box; firmware auto-zero (AN1636) compensates for mounting-induced zero shift without hardware modification. |
Applications
| Washing Machine Water Level Sensing | Medical Nebulizer Flow Monitoring |
|---|---|
Use Scenario: Detecting water fill level in top-loading washing machines via air pressure in a sealed tube connected to the tub. IC Role / Device Role / Timing Role: Analog pressure transducer converting hydrostatic pressure into calibrated voltage for MCU ADC sampling. Use Value: Enables precise 0–400 mm H₂O detection with ±1.5% VFSS accuracy, supporting multi-level fill control and reducing overflow risk without mechanical float switches. | Use Scenario: Monitoring airflow-induced pressure drop across nebulizer chamber to infer aerosol generation status and flow rate. IC Role / Device Role / Timing Role: Differential pressure sensor measuring ΔP between inlet and outlet to infer flow continuity and blockage. Use Value: Provides stable 0.6–3.0 V output across 10–60°C ambient, allowing real-time flow validation using low-cost 10-bit MCU ADC without external amplification. |
| HVAC Duct Static Pressure Control | Consumer Appliance Airflow Verification |
Use Scenario: Measuring static pressure in HVAC ducts to regulate blower speed and maintain target airflow under variable filter loading. IC Role / Device Role / Timing Role: Gauge pressure sensor referenced to ambient, detecting pressure rise/fall as duct resistance changes. Use Value: Delivers repeatable 0–3.92 kPa response with <10 mA supply current, enabling battery-backed or energy-harvested duct monitoring nodes. | Use Scenario: Verifying fan operation and airflow path integrity in coffee makers, air purifiers, and dehumidifiers during power-up self-test. IC Role / Device Role / Timing Role: Low-range pressure switch replacement, detecting presence/absence of airflow-induced pressure differential. Use Value: Eliminates moving parts and contact wear; NC pins simplify PCB routing, and ratiometric output ensures consistent trip thresholds across varying supply conditions. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar gauge pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPXV5004GC6U | Successor part from NXP (post-Freescale acquisition); identical pinout, package, and transfer function; improved long-term stability spec (±0.5% VFSS typical drift over 1000 cycles). | Same 0–400 mm H₂O range and ratiometric output; qualified for extended temperature cycling (−30°C to +100°C storage) and higher media compatibility. | Select when lifecycle assurance and enhanced reliability testing are required; drop-in replacement with no layout change. |
| DLHR-0010D | 0–10 kPa range, 0.5–4.5 V output, I²C digital interface; requires external MCU firmware for calibration and temperature compensation. | Higher full-scale range and digital output suit industrial controllers needing programmable thresholds; lacks integrated analog signal conditioning. | Select when digital interface, wider pressure range, or field recalibration capability is prioritized over analog simplicity and low-component-count design. |
Compared with MP3V5004GC6U, MPXV5004GC6U offers identical form-fit-function with superior long-term stability, while DLHR-0010D trades analog simplicity for digital configurability and extended range-making MP3V5004GC6U optimal for cost-sensitive, fixed-threshold consumer appliance designs.
Availability
MP3V5004GC6U is available at Aetrix Electronics and suitable for washing machine water level sensing, medical nebulizer flow monitoring, and HVAC duct static pressure control requiring stable component supply, long-lifecycle support, and consistent factory calibration across production batches.
Supply support for MP3V5004GC6U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Freescale Semiconductor was a leading designer of embedded processors, analog, and sensor ICs, acquired by NXP Semiconductors in 2015. Its pressure sensor portfolio emphasized high-reliability, system-integrated solutions for automotive and appliance markets.
The MP3V5004GC6U belongs to Freescale's MP3V5004G series of fully integrated silicon pressure sensors-designed specifically for microcontroller-based consumer appliances where low-cost, calibrated analog output and robust packaging are essential.
FAQ
What is the pressure media compatibility of the MP3V5004GC6U?
The MP3V5004GC6U is characterized and qualified for dry air as the pressure medium. Use with other gases or liquids may degrade performance or reliability. Freescale's internal qualification testing was conducted exclusively with dry air; media tolerance data for alternate substances must be requested directly from NXP (successor to Freescale) prior to deployment. The fluorosilicone gel die coat provides basic moisture resistance but does not guarantee compatibility with condensing or corrosive media.
Does the MP3V5004GC6U require external decoupling capacitors?
Yes, the MP3V5004GC6U requires external decoupling: a 1.0 μF bulk capacitor and a 0.01 μF ceramic capacitor placed close to Pins 3 (GND) and 4 (VS). Figure 3 in the datasheet specifies this configuration to suppress supply noise and prevent output instability. Omitting these capacitors risks increased offset drift and reduced accuracy, especially in electrically noisy appliance environments.
How is the pressure side (P1) identified on the MP3V5004GC6U package?
For the MP3V5004GC6U in Case 482A, the pressure side (P1) is the side with the physical port attached-visible as an open channel or molded aperture aligned with the sensing diaphragm. This is explicitly confirmed in the Pressure (P1)/Vacuum (P2) Side Identification Table. Mounting must ensure P1 faces the measured pressure source and P2 remains vented to ambient or sealed as required by the application.
What is the maximum overpressure rating for the MP3V5004GC6U?
MP3V5004GC6U has a maximum pressure rating of 16 kPa (P1 > P2). Exceeding this value-even momentarily-may cause permanent damage to the silicon diaphragm or bonding wires. This limit applies regardless of duration or temperature; it is not a surge rating. Applications involving potential pressure spikes must include mechanical stoppers or relief valves upstream of the MP3V5004GC6U.
Can the MP3V5004GC6U operate outside its compensated temperature range?
Yes, the MP3V5004GC6U operates from 0°C to +85°C, but temperature compensation is only guaranteed from 10°C to 60°C. Outside this band, offset and span drift increase beyond the ±1.5% VFSS specification-typical error may exceed ±5% VFSS at 0°C or 85°C. For applications requiring accuracy across the full operating range, external compensation or calibration is necessary; the device remains functional but not specification-compliant.
MP3V5004GC6U Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MP3V5004
- Package/Case:
- 8-SMD, Gull Wing, Top Port
- Packaging:
- Tube
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 0.57PSI (3.92kPa)
- Output Type:
- Analog Voltage
- Output:
- 0.6 V ~ 3 V
- Accuracy:
- ±2.5%
- Voltage - Supply:
- 2.7V ~ 3.3V
- Port Size:
- Male - 0.13" (3.17mm) Tube
- Port Style:
- Barbless
- Features:
- Temperature Compensated
- Termination Style:
- Gull Wing
- Maximum Pressure:
- 2.32PSI (16kPa)
- Operating Temperature:
- 0°C ~ 85°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- -
MP3V5004GC6U FAQ
1.How can I place an order for MP3V5004GC6U through Aetrix?
Please submit a Request for Quotation (RFQ) for MP3V5004GC6U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MP3V5004GC6U reliable?
The price and inventory of MP3V5004GC6U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MP3V5004GC6U is usually 5 days.
3.What payment methods are accepted for MP3V5004GC6U?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MP3V5004GC6U transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MP3V5004GC6U?
MP3V5004GC6U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MP3V5004GC6U order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MP3V5004GC6U?
For technical support, including MP3V5004GC6U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MP3V5004GC6U requirements.
6.How does Aetrix verify that MP3V5004GC6U is sourced from the original manufacturer or authorized distributors?
All MP3V5004GC6U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MP3V5004GC6U meets industry standards.
7.What is the process for return or replacement of MP3V5004GC6U?
All MP3V5004GC6U units undergo pre-shipment inspection (PSI). If there is an issue with MP3V5004GC6U, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MP3V5004GC6U part is unused and in its original packaging.
Return procedure for MP3V5004GC6U:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MP3V5004GC6U Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…