NXP Semiconductors MP3V5004GP
- Part No.:
- MP3V5004GP
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 8-SMD, Gull Wing, Side Port
- Datasheet:
-
MP3V5004GP.pdf
- Description:
- SENSOR 0.57PSIG 0.13" 3V 8SOP
- Quantity:
- Payment:

- Shipping:

Inventory:3,965
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MP3V5004GP from Freescale Semiconductor is a monolithic silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and factory calibration. It delivers a ratiometric 0.6–3.0 V analog output proportional to applied gauge pressure (0–3.92 kPa), operates from 2.7–3.3 V supply, draws ≤10 mA, and targets microcontroller-based water level sensing in appliances.
For engineers reviewing the MP3V5004GP datasheet, MP3V5004GP pinout, MP3V5004GP application, or MP3V5004GP equivalent, key selection criteria include its 0–400 mm H₂O range, ±1.5% VFSS accuracy at low pressure (0–100 mm H₂O), thermoplastic PPS package (Case 1369), and differential port configuration requiring correct P1/P2 side orientation during PCB layout.
Technical Context
The MP3V5004GP integrates a shear-stress strain gauge, thin-film temperature compensation network, and two-stage gain/offset circuitry onto a single die. Its transfer function is VOUT = VS × [(0.2 × P) + 0.2] ±2.5% VFSS, where P is pressure in kPa and VS is supply voltage (3.0 V ±0.3 V).
It is ratiometric, meaning output scale and offset track supply voltage variation; operates over 0–85°C ambient but achieves specified accuracy only from 10–60°C; and requires dry air as pressure medium to maintain long-term reliability and calibrated performance.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–3.92 kPa (0–400 mm H₂O) - full-scale range for gauge pressure measurement with P1 > P2 |
| Output Voltage | 0.6–3.0 V - ratiometric analog output referenced to supply voltage, linear with pressure |
| Supply Voltage | 2.7–3.3 V DC - excitation range enabling direct interface with 3.3 V microcontrollers |
| Supply Current | ≤10 mA - enables low-power operation in battery-backed or energy-conscious systems |
| Accuracy | ±1.5% VFSS (0–100 mm H₂O), ±2.5% VFSS (100–400 mm H₂O) - error budget includes linearity, temp hysteresis, and offset stability |
| Operating Temp | 0–85°C - functional range; compensated accuracy guaranteed only from 10–60°C |
| Max Pressure | 16 kPa - absolute maximum rating before mechanical damage or permanent shift |
Pinout & Package
MP3V5004GP uses a thermoplastic PPS small-outline package (Case 1369), surface-mountable with 8 leads. Pins 1, 5, 6, 7, and 8 are No Connects; active terminals are Pin 2 (VOUT), Pin 3 (GND), and Pin 4 (VS). The pressure port is located on the side marked "Side with Port Attached" per Freescale's identification table.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Pin 2 | VOUT | Analog output signal - provides 0.6–3.0 V ratiometric voltage proportional to applied pressure |
| Pin 3 | GND | Ground reference - must be connected to system ground with low-impedance path to minimize noise |
| Pin 4 | VS | Supply input - accepts 2.7–3.3 V DC; output scales directly with this voltage |
| Pins 1,5,6,7,8 | No Connect | Internally unconnected - must remain floating; no external connection permitted |
Key Features
| Feature | Design Value |
|---|---|
| On-chip signal conditioning | Eliminates need for external op-amps or ADC front-end circuitry; outputs clean, amplified analog voltage |
| Factory temperature compensation | Ensures ±1.5% VFSS accuracy across 10–60°C without user calibration or software correction |
| Differential pressure porting | Enables precise measurement of pressure difference (P1 > P2); stainless steel cap protects sensing element |
| Ratiometric output | Output scaling tracks supply voltage variation - simplifies integration with 3.3 V MCU ADC references |
| Fluorosilicone gel isolation | Protects wire bonds and die from environmental moisture while transmitting pressure signal to diaphragm |
Applications
| Washing Machine Water Level Detection | Home Appliance Air Flow Monitoring |
|---|---|
Use Scenario: Detecting water fill level in top-loading washing machines by measuring air pressure in a sealed tube connected to the tub. IC Role / Device Role / Timing Role: MP3V5004GP acts as the primary pressure transducer, converting pneumatic pressure into a stable analog voltage for MCU A/D conversion. Use Value: Enables accurate, repeatable water level control within ±10 mm H₂O using its ±1.5% VFSS low-range accuracy and factory auto-zero capability. | Use Scenario: Monitoring airflow resistance across HVAC filters in smart home thermostats to trigger maintenance alerts. IC Role / Device Role / Timing Role: MP3V5004GP measures differential pressure drop across the filter media to infer clogging state. Use Value: Leverages its 0–400 mm H₂O range and 10–60°C compensated operation to deliver reliable readings across seasonal ambient shifts. |
| Medical Nebulizer Pressure Feedback | Industrial Vacuum Leak Detection |
Use Scenario: Verifying consistent aerosol generation pressure in portable nebulizers used for respiratory therapy. IC Role / Device Role / Timing Role: MP3V5004GP monitors outlet pressure to ensure therapeutic delivery within prescribed 2–3 kPa range. Use Value: Provides factory-calibrated output with <10 mA supply current, supporting compact, battery-operated medical designs. | Use Scenario: Detecting minute vacuum leaks in sealed packaging lines by monitoring pressure decay rate in test chambers. IC Role / Device Role / Timing Role: MP3V5004GP serves as the high-stability gauge sensor, capturing sub-kPa pressure changes over time. Use Value: Delivers long-term offset stability after 1000 thermal cycles and 1.5M pressure cycles - critical for production-line repeatability. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar pressure transducer applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPXV5004GC6U | Same die, Case 482A package; rail packaging; identical electrical specs and accuracy | Requires different PCB footprint (Case 482A vs. Case 1369); same P1-side port orientation | Select when board space allows larger SOP-8 and tape-and-reel logistics are preferred |
| MP3V5050GP | Higher full-scale range (0–50 kPa); same package, supply, and output architecture | Not suitable for sub-4 kPa applications due to reduced resolution and accuracy at low pressure | Choose only if system requires extended range beyond 3.92 kPa; avoid for water-level use cases |
Compared with MP3V5004GP, MPXV5004GC6U offers identical sensing performance in a different package format, while MP3V5050GP trades low-end precision for higher pressure capability - making MP3V5004GP optimal for 0–400 mm H₂O applications demanding best-in-class accuracy at low pressure.
Availability
MP3V5004GP is available at Aetrix Electronics and suitable for washing machine water level detection, HVAC airflow monitoring, medical nebulizer feedback, and industrial vacuum leak detection requiring stable component supply and long-term calibration integrity.
Supply support for MP3V5004GP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Freescale Semiconductor (now part of NXP Semiconductors) was a leading designer of embedded processors and sensors, known for automotive, industrial, and consumer ICs with robust qualification and long-lifecycle support.
The MP3V5004GP belongs to Freescale's MP3V series of integrated silicon pressure sensors, engineered specifically for cost-sensitive, microcontroller-based systems needing calibrated analog output without external signal conditioning.
FAQ
What is the pressure port configuration of the MP3V5004GP?
The MP3V5004GP features a differential pressure port configuration with designated Pressure (P1) and Vacuum (P2) sides. Per Freescale documentation, the P1 side is identified as "Side with Port Attached" for Case 1369. Correct orientation is essential: P1 must face the pressurized medium and P2 the reference (typically ambient or vacuum). Mounting with reversed sides causes inverted or saturated output.
Does the MP3V5004GP require external calibration or zeroing?
The MP3V5004GP is factory-calibrated and temperature-compensated, eliminating need for end-user calibration. However, Freescale recommends auto-zeroing in-system to cancel mounting-induced offset - storing the zero-pressure output at installation and subtracting it from subsequent readings. This step is critical for achieving ±1.5% VFSS accuracy in the 0–100 mm H₂O range, as specified in AN1636.
What is the recommended power supply decoupling for the MP3V5004GP?
Freescale specifies a decoupling network consisting of a 1.0 μF bulk capacitor, a 0.01 μF ceramic capacitor, and a 470 pF filter capacitor between VS and GND, placed as close as possible to Pins 4 and 3. This configuration suppresses supply noise and prevents output ripple, especially important when interfacing with high-resolution ADCs. Failure to implement this network may degrade effective resolution and introduce measurement drift.
Can the MP3V5004GP be used with media other than dry air?
Freescale explicitly qualifies the MP3V5004GP for dry air only. Exposure to moisture, oils, solvents, or corrosive gases may degrade fluorosilicone gel integrity, cause wire bond corrosion, or shift calibration. For non-air media, users must contact NXP (ex-Freescale) for media compatibility testing data; no performance or reliability guarantees apply outside dry air operation.
What is the maximum operating pressure before damage occurs for the MP3V5004GP?
The MP3V5004GP has an absolute maximum pressure rating of 16 kPa (16000 mm H₂O) as defined in its Maximum Ratings table. Exceeding this value risks permanent mechanical deformation of the silicon diaphragm or bond wire failure. While the sensor operates linearly up to 3.92 kPa, transient spikes above 16 kPa - even briefly - may cause irreversible damage or calibration shift. System design must include overpressure protection.
MP3V5004GP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MP3V5004
- Package/Case:
- 8-SMD, Gull Wing, Side Port
- Packaging:
- Tray
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 0.57PSI (3.92kPa)
- Output Type:
- Analog Voltage
- Output:
- 0.6 V ~ 3 V
- Accuracy:
- ±2.5%
- Voltage - Supply:
- 2.7V ~ 3.3V
- Port Size:
- Male - 0.13" (3.17mm) Tube
- Port Style:
- Barbed
- Features:
- Temperature Compensated
- Termination Style:
- Gull Wing
- Maximum Pressure:
- 2.32PSI (16kPa)
- Operating Temperature:
- 0°C ~ 85°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 8-SOP
MP3V5004GP FAQ
1.How can I place an order for MP3V5004GP through Aetrix?
Please submit a Request for Quotation (RFQ) for MP3V5004GP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MP3V5004GP reliable?
The price and inventory of MP3V5004GP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MP3V5004GP is usually 5 days.
3.What payment methods are accepted for MP3V5004GP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MP3V5004GP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MP3V5004GP?
MP3V5004GP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MP3V5004GP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MP3V5004GP?
For technical support, including MP3V5004GP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MP3V5004GP requirements.
6.How does Aetrix verify that MP3V5004GP is sourced from the original manufacturer or authorized distributors?
All MP3V5004GP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MP3V5004GP meets industry standards.
7.What is the process for return or replacement of MP3V5004GP?
All MP3V5004GP units undergo pre-shipment inspection (PSI). If there is an issue with MP3V5004GP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MP3V5004GP part is unused and in its original packaging.
Return procedure for MP3V5004GP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MP3V5004GP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…