NXP Semiconductors MP3V5010GC6U

Part No.:
MP3V5010GC6U
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
8-SMD, Gull Wing, Top Port
Datasheet:
AetrixMP3V5010GC6U.pdf
Description:
SENSOR 1.45PSIG 0.13" 3.1V 8SOP
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:4,515

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MP3V5010GC6U from Freescale Semiconductor is a monolithic silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and factory calibration. It delivers a ratiometric analog output (0.1–3.1 V) over a 0–10 kPa gauge pressure range, operates from 2.7–3.3 V supply, consumes ≤10 mA, and achieves ±5.0% full-scale accuracy across 0–85°C - deployed in respiratory systems and HVAC sensing.

For engineers reviewing the MP3V5010GC6U datasheet, MP3V5010GC6U pinout, MP3V5010GC6U application, or MP3V5010GC6U equivalent, key selection criteria include its thermoplastic PPS surface-mount package (Case 482A), differential/gauge configuration support, fluoro-silicone gel media isolation, and compatibility with microcontroller A/D inputs requiring low-offset, stable analog pressure feedback.

Technical Context

The MP3V5010GC6U integrates a patented silicon shear-stress strain gauge with thin-film metallization and bipolar signal conditioning circuitry on a single die. Its transfer function is Vout = VS × (0.09 × P + 0.08), where output scales linearly with pressure and supply voltage - enabling ratiometric measurement immunity to VS drift.

On-chip temperature compensation corrects offset and span errors across –40°C to +125°C operating range, while internal gain stages and ground-reference shift circuitry deliver a buffered, low-impedance output capable of sourcing 0.1 mA at full scale. The device requires external decoupling (1.0 μF + 0.01 μF + 470 pF) per Figure 3 for specified performance.

Key Specifications

ParameterValue and Actual Design Meaning
Pressure Range0–10 kPa gauge - supports low-pressure medical and environmental monitoring with 1.45 psi full scale.
Output Voltage0.1–3.1 V ratiometric - tracks supply voltage (2.7–3.3 V), eliminating need for separate reference in MCU-based systems.
Accuracy±5.0% VFSS over 0–85°C - includes linearity, temp hysteresis, pressure hysteresis, TcSpan, and TcOffset contributions.
Sensitivity270 mV/kPa - enables high-resolution pressure detection with <0.04 kPa LSB at 12-bit ADC resolution.
Response Time1.0 ms (10%–90%) - suitable for dynamic pressure events such as breath cycle tracking in ventilators.
Supply Current7.0 mA typical - allows integration into battery-powered portable diagnostics without excessive power burden.
Operating Temp–40°C to +125°C - supports deployment in automotive under-hood or industrial process control environments.

Pinout & Package

MP3V5010GC6U uses a thermoplastic (PPS) Small Outline Package (Case 482A-01), 8-pin surface-mount housing with 2.54 mm pitch, 10.54 × 10.54 × 3.17 mm footprint, and pin 1 identifier marked on top. Pins 5–8 are no-connects; functional terminals are GND, Vout, Vs, and –Vout (Style 1).

Pin/TerminalCircuit RoleDesign Meaning
1GNDGround reference for signal conditioning circuitry and output stage - must be low-impedance connection to minimize noise coupling.
2+VoutAnalog output terminal - provides buffered, temperature-compensated voltage proportional to applied pressure (0.1–3.1 V).
3VsSupply input - accepts 2.7–3.3 V DC; output is ratiometric to this rail, requiring stable regulation or direct MCU VDD tie.
4–VoutDifferential output complement - used with +Vout for noise-rejecting differential A/D acquisition in high-interference environments.
5–8No ConnectInternally unconnected - must remain floating; no PCB traces or solder mask openings required.

Key Features

FeatureDesign Value
Patented silicon shear-stress strain gaugeEnables high stability and low hysteresis (<±0.5% VFSS offset drift after 1000-hour stress test) versus conventional piezoresistive elements.
On-chip temperature compensationCorrects both offset and full-scale span across –40°C to +125°C, eliminating need for external thermistor or digital correction in embedded systems.
Fluoro-silicone gel isolationProtects die and wire bonds from moisture and chemical exposure while transmitting pressure accurately - validated for dry air media compatibility.
Ratiometric output architectureOutput voltage scales directly with supply rail, allowing direct interface to MCU ADC reference without external voltage reference IC.
Small Outline Package (Case 482A)Enables automated SMT assembly and compact board layout in space-constrained applications like portable medical devices.

Applications

Hospital BedsHVAC Systems

Use Scenario: Real-time patient weight and position monitoring via mattress-integrated pressure zones.

IC Role / Device Role / Timing Role: Analog pressure transducer converting localized air bladder pressure into calibrated voltage for microcontroller A/D sampling.

Use Value: Enables low-power, high-accuracy load detection with ±5.0% full-scale accuracy and 1 ms response - critical for fall-risk alerts and pressure ulcer prevention logic.

Use Scenario: Duct static pressure and filter clog detection in commercial rooftop HVAC units.

IC Role / Device Role / Timing Role: Gauge pressure sensor measuring differential airflow resistance across heat exchangers and filters.

Use Value: Provides 0–10 kPa full-scale range matched to typical HVAC pressure differentials, with temperature compensation ensuring stable readings across ambient –40°C to +85°C operation.

Respiratory SystemsProcess Control

Use Scenario: Inspiratory/expiratory airway pressure monitoring in portable ventilators and CPAP machines.

IC Role / Device Role / Timing Role: Low-latency pressure transducer feeding real-time closed-loop pressure control algorithms.

Use Value: Delivers 1.0 ms response time and ratiometric output - enabling precise breath-phase synchronization and compliance with ISO 80601-2-69 pressure accuracy requirements.

Use Scenario: Low-pressure liquid level and flow rate inference in pharmaceutical or food-grade filling lines.

IC Role / Device Role / Timing Role: Factory-calibrated gauge sensor interfaced to PLC analog input modules for continuous process feedback.

Use Value: Eliminates field calibration with ±5.0% accuracy over 0–85°C and long-term offset stability (±0.5% VFSS after 1000-hour stress), reducing maintenance downtime.

Equivalent & Alternatives

The following parts are listed as comparable options for similar pressure transducer applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
MPXV5004GPSame Freescale family; 0–4 kPa range, 0.2–2.8 V output, Case 1369 tray packaging - lower full-scale pressure and different footprint.Optimized for sub-1 psi vacuum/low-differential sensing; not drop-in due to different pressure range and package dimensions.Select when system requires <4 kPa full scale and tray-based procurement; verify PCB land pattern against Case 1369-01.
SPX3115-001-D-3LInfineon device; 0–15 kPa range, 0.5–4.5 V output, SOIC-8 package - higher full-scale range and wider output swing but no integrated temperature compensation.Requires external compensation circuitry or software correction; suited for cost-sensitive industrial gauges where ±1% accuracy is acceptable.Choose when broader pressure range or higher output voltage is needed and design can accommodate external calibration.

Compared with MP3V5010GC6U, MPXV5004GP offers lower-range precision for vacuum-critical applications but demands PCB redesign, while SPX3115-001-D-3L trades built-in compensation for extended range and output headroom - making MP3V5010GC6U optimal for plug-and-play, temperature-stable 0–10 kPa medical sensing.

Availability

MP3V5010GC6U is available at Aetrix Electronics and suitable for hospital beds, HVAC systems, and respiratory systems requiring stable component supply, long-lifecycle assurance, and consistent factory calibration across production batches.

Supply support for MP3V5010GC6U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Freescale Semiconductor (now part of NXP Semiconductors) was a leading designer of embedded processors and sensors, specializing in automotive, industrial, and medical-grade analog and mixed-signal ICs.

The MP3V5010 series was developed specifically for microcontroller-based pressure monitoring in safety-critical medical and environmental systems - emphasizing on-chip calibration, media-isolated construction, and wide-temperature reliability without external compensation components.

FAQ

What is the pressure media compatibility of the MP3V5010GC6U?

The MP3V5010GC6U is qualified for use with dry air as the pressure media. Its fluoro-silicone gel die coating isolates the sensing element from environmental contaminants while transmitting pressure accurately. Other media may affect long-term reliability or accuracy; Freescale recommends contacting factory application engineering before deploying MP3V5010GC6U with non-dry-air fluids or gases.

Does the MP3V5010GC6U require external decoupling capacitors?

Yes, the MP3V5010GC6U requires a specific decoupling network per Figure 3 in the datasheet: 1.0 μF, 0.01 μF, and 470 pF capacitors between Vs and GND. This network is mandatory to meet the ±5.0% accuracy specification and suppress supply-induced noise - omitting it degrades linearity and temperature stability in the MP3V5010GC6U output.

What does "Gauge" mean in MP3V5010GC6U's part number suffix?

The "G" in MP3V5010GC6U denotes gauge pressure configuration - meaning the sensor measures pressure relative to ambient atmospheric pressure using a single port (P1) exposed to media and a vented reference cavity (P2). This differs from differential (D) or absolute (A) variants and defines how MP3V5010GC6U interfaces mechanically and electrically in the system.

Can the MP3V5010GC6U operate from a 5 V supply?

No, the MP3V5010GC6U is rated for 2.7–3.3 V supply only. Exceeding 3.3 Vdc violates Absolute Maximum Ratings and may cause permanent damage. For 5 V systems, a dedicated 3.3 V LDO regulator must supply the MP3V5010GC6U - its ratiometric output ensures accuracy remains tied to that regulated rail, not the main 5 V bus.

How is the pressure side (P1) identified on the MP3V5010GC6U package?

The pressure side (P1) of the MP3V5010GC6U is the side with the port attached - visible as an open aperture on the thermoplastic case. Per Freescale's identification table, MP3V5010GC6U/C6T1 uses Case 482A and is marked with the port on the P1 side; applying positive differential pressure (P1 > P2) is required for correct operation of the MP3V5010GC6U.

MP3V5010GC6U Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MP3V5010
Package/Case:
8-SMD, Gull Wing, Top Port
Packaging:
Tube
Product Status:
Obsolete
Applications:
Board Mount
Pressure Type:
Vented Gauge
Operating Pressure:
1.45PSI (10kPa)
Output Type:
Analog Voltage
Output:
0.1 V ~ 3.1 V
Accuracy:
±5%
Voltage - Supply:
2.7V ~ 3.3V
Port Size:
Male - 0.13" (3.17mm) Tube
Port Style:
Barbless
Features:
Temperature Compensated
Termination Style:
Gull Wing
Maximum Pressure:
10.88PSI (75kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
-

MP3V5010GC6U FAQ

1.How can I place an order for MP3V5010GC6U through Aetrix?

Please submit a Request for Quotation (RFQ) for MP3V5010GC6U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MP3V5010GC6U reliable?

The price and inventory of MP3V5010GC6U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MP3V5010GC6U is usually 5 days.

3.What payment methods are accepted for MP3V5010GC6U?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MP3V5010GC6U transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MP3V5010GC6U?

MP3V5010GC6U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MP3V5010GC6U order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MP3V5010GC6U?

For technical support, including MP3V5010GC6U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MP3V5010GC6U requirements.

6.How does Aetrix verify that MP3V5010GC6U is sourced from the original manufacturer or authorized distributors?

All MP3V5010GC6U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MP3V5010GC6U meets industry standards.

7.What is the process for return or replacement of MP3V5010GC6U?

All MP3V5010GC6U units undergo pre-shipment inspection (PSI). If there is an issue with MP3V5010GC6U, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MP3V5010GC6U part is unused and in its original packaging.

Return procedure for MP3V5010GC6U:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MP3V5010GC6U Tags

  • MP3V5010GC6U
  • MP3V5010GC6U PDF
  • MP3V5010GC6U Datasheet
  • MP3V5010GC6U Specifications
  • MP3V5010GC6U Images
  • NXP Semiconductors
  • NXP Semiconductors MP3V5010GC6U
  • Buy MP3V5010GC6U
  • MP3V5010GC6U Price
  • MP3V5010GC6U Distributor
  • MP3V5010GC6U Supplier
  • MP3V5010GC6U Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER