NXP Semiconductors MP3V5050GC6U
- Part No.:
- MP3V5050GC6U
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 8-SMD, Gull Wing, Top Port
- Datasheet:
-
MP3V5050GC6U.pdf
- Description:
- SENSOR 7.25PSIG 0.13" 2.82V
- Quantity:
- Payment:

- Shipping:

Inventory:984
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MP3V5050GC6U from NXP is a monolithic silicon piezoresistive gauge pressure sensor with 0–50 kPa full-scale range, ratiometric analog output (2.7–2.888 V at 3.0 V supply), ±2.5% accuracy over 0 °C to 85 °C, and on-chip temperature compensation across –40 °C to +125 °C. It interfaces directly with microcontroller A/D inputs in medical diagnostics and pump control systems.
For engineers reviewing the MP3V5050GC6U datasheet, MP3V5050GC6U pinout, MP3V5050GC6U application, or MP3V5050GC6U equivalent, this page delivers verified package mapping (Case 98ASB17757C), confirmed pin functions, real-world use value for pressure switching and level detection, and two validated alternative parts with documented technical differences.
Technical Context
The MP3V5050GC6U integrates a patented silicon shear-stress strain gauge with thin-film metallization and bipolar processing to deliver a high-level analog output proportional to applied gauge pressure. Its transfer function is VOUT = VS × (0.018 × P + 0.04), with sensitivity of 54 mV/kPa and response time ≤1.0 ms.
On-chip temperature compensation corrects offset and span drift across –40 °C to +125 °C using internal circuitry; error bands are bounded by ±1.25 kPa pressure hysteresis and ±0.5% VFSS offset stability after 1000-hour stress testing. The device requires a decoupling network (1.0 μF + 470 pF) per Figure 5 for stable A/D interfacing.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–50 kPa gauge; supports blood pressure monitoring and low-pressure industrial sensing. |
| Supply Voltage | 2.7–3.3 VDC; ratiometric operation ensures output scaling matches ADC reference voltage. |
| Full-Scale Output | 2.752–2.888 V at 3.0 V supply; enables direct connection to 3.3 V MCU ADC without signal conditioning. |
| Accuracy | ±2.5% VFSS over 0–85 °C; includes linearity, temp hysteresis, pressure hysteresis, and TcSpan/TcOffset. |
| Response Time | ≤1.0 ms (10%–90%); suitable for dynamic pressure events in robotics and motor control feedback loops. |
| Operating Temp | –40 °C to +125 °C; qualified for under-hood automotive and industrial embedded environments. |
Pinout & Package
MP3V5050GC6U uses a thermoplastic (PPS) small outline package (Case 98ASB17757C), surface-mountable with vertical porting for robust tube connection. Pin 1 is identified by notch; pins 5–8 are no-connects.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | DNC | Do not connect; mechanical pin 1 identifier (notch side); floating per spec. |
| 2 | VS | 3.0 V ±0.3 V supply input; requires 1.0 μF + 470 pF decoupling per Figure 5. |
| 3 | GND | Analog ground reference; must be low-impedance return path for sensor and ADC. |
| 4 | VOUT | Ratiometric analog output (0.053–2.888 V); connects directly to 12-bit+ MCU ADC input. |
| 5–8 | DNC | No-connect terminals; electrically isolated; must remain unconnected per Table 1. |
Key Features
| Feature | Design Value |
|---|---|
| Patented silicon shear-stress strain gauge | Enables high repeatability and low hysteresis (±1.25 kPa) in long-term medical and industrial deployments. |
| On-chip temperature compensation | Eliminates need for external calibration circuitry across –40 °C to +125 °C operating range. |
| Fluorosilicone gel die coating | Protects wire bonds and die from moisture and chemical exposure while transmitting pressure accurately. |
| Vertical port configuration | Enables compact PCB layout with barbed tube attachment perpendicular to board surface. |
Applications
| Blood Pressure Monitoring | Pump/Motor Control |
|---|---|
Use Scenario: Continuous non-invasive cuff-based or catheter-tipped pressure acquisition in clinical and portable diagnostic devices. IC Role / Device Role / Timing Role: Primary gauge pressure transducer converting arterial pressure into calibrated analog voltage for MCU sampling. Use Value: ±2.5% VFSS accuracy and ±0.5% VFSS offset stability ensure repeatable readings across 1000+ pressure cycles required for FDA-cleared devices. |
Use Scenario: Real-time feedback of fluid pressure in HVAC compressors, vacuum pumps, or centrifugal blower systems. IC Role / Device Role / Timing Role: Closed-loop pressure sensing element feeding analog signal to motor driver controller for speed modulation. Use Value: 1.0 ms response time and ratiometric output allow precise duty-cycle adjustment within <10 ms control loop windows. |
| Level Detection | Robotics Actuation |
Use Scenario: Liquid height measurement in tanks or reservoirs via hydrostatic pressure at fixed depth. IC Role / Device Role / Timing Role: Static gauge pressure sensor referenced to atmospheric vent, translating column height to kPa. Use Value: 0–50 kPa range covers ~0–5 m water column; temperature-compensated offset prevents drift during ambient thermal cycling. |
Use Scenario: Force feedback in pneumatic/hydraulic robotic joints or end-effectors requiring pressure-regulated actuation. IC Role / Device Role / Timing Role: Dynamic differential pressure monitor detecting chamber pressure changes during motion sequences. Use Value: Vertical porting simplifies integration into compact joint housings; fluorosilicone gel ensures reliability under repeated mechanical vibration. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar gauge pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5050GP | Same 0–50 kPa range and SOP-8 package but uses older Case 98ASA99303D; lacks vertical port; offset drift ±3.0% VFSS over 0–85 °C. | Requires horizontal port routing; less suited for space-constrained medical cuffs or robotic joints. | Select MPX5050GP only if legacy footprint compatibility is mandatory and vertical porting is unnecessary. |
| MP3V5004DP | Differential variant (0–4 kPa range); same Case 98ASB17757C package and vertical port; ±1.5% VFSS accuracy; lower sensitivity (135 mV/kPa). | Designed for ultra-low-pressure differential sensing (e.g., airflow in ventilators), not gauge applications. | Choose MP3V5004DP only when measuring pressure differentials <5 kPa with high resolution; not a functional substitute for MP3V5050GC6U's gauge function. |
Compared with MPX5050GP, MP3V5050GC6U offers tighter accuracy and vertical porting; compared with MP3V5004DP, it provides 12.5× higher full-scale range and gauge (not differential) operation-critical for blood pressure and tank level use cases.
Availability
MP3V5050GC6U is available at Aetrix Electronics and suitable for medical diagnostics, pump/motor control, and level detection applications requiring stable component supply, long-term lifecycle support, and traceable sourcing.
Supply support for MP3V5050GC6U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors is a global semiconductor company specializing in secure connectivity solutions for automotive, industrial, and IoT markets, with leadership in sensor signal conditioning and embedded analog front-ends.
The MP3V5050 series was designed for microcontroller-based systems needing calibrated, temperature-compensated analog pressure outputs-targeting medical, industrial automation, and consumer health applications.
FAQ
What is the pressure type and range supported by the MP3V5050GC6U?
The MP3V5050GC6U is a gauge pressure sensor with a full-scale range of 0–50 kPa. It measures pressure relative to ambient atmospheric pressure using a single port (P1) with vertical orientation per Case 98ASB17757C. This range corresponds to approximately 0–7.25 psi and supports applications including blood pressure monitoring and liquid level detection.
Does the MP3V5050GC6U require external calibration or compensation circuitry?
No, the MP3V5050GC6U includes on-chip temperature compensation and factory calibration across –40 °C to +125 °C. Its output is ratiometric and stable within ±2.5% VFSS over 0–85 °C without external components. Only recommended decoupling (1.0 μF + 470 pF) is needed per Figure 5 in the datasheet for reliable MCU interfacing.
What is the correct pinout and package for MP3V5050GC6U?
The MP3V5050GC6U uses Case 98ASB17757C-a thermoplastic small outline package with vertical porting. Pinout (top view, notch at Pin 1) is: Pin 1 = DNC, Pin 2 = VS, Pin 3 = GND, Pin 4 = VOUT, Pins 5–8 = DNC. All DNC pins must remain unconnected per NXP specification.
Can MP3V5050GC6U be used in differential pressure configurations?
No, MP3V5050GC6U is specified exclusively as a gauge pressure sensor with one active port (P1). It is not rated or characterized for differential operation. For differential sensing, NXP offers the MP3V5050DP variant (Case 98ASA99255D), which has dual ports and separate P1/P2 designation.
What is the maximum supply current and warm-up time for MP3V5050GC6U?
The MP3V5050GC6U draws 7.0 mA typical supply current (max 10 mA) at 3.0 V. Its warm-up time-the duration required to meet specified output voltage after pressure stabilization-is 20 ms. This allows rapid system initialization in battery-powered or responsive control applications.
MP3V5050GC6U Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MP3V5050
- Package/Case:
- 8-SMD, Gull Wing, Top Port
- Packaging:
- Tube
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 7.25PSI (50kPa)
- Output Type:
- Analog Voltage
- Output:
- 0.06 V ~ 2.82 V
- Accuracy:
- ±2.5%
- Voltage - Supply:
- 2.7V ~ 3.3V
- Port Size:
- Male - 0.13" (3.17mm) Tube
- Port Style:
- Barbed
- Features:
- Temperature Compensated
- Termination Style:
- Gull Wing
- Maximum Pressure:
- 29.01PSI (200kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- -
MP3V5050GC6U FAQ
1.How can I place an order for MP3V5050GC6U through Aetrix?
Please submit a Request for Quotation (RFQ) for MP3V5050GC6U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MP3V5050GC6U reliable?
The price and inventory of MP3V5050GC6U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MP3V5050GC6U is usually 5 days.
3.What payment methods are accepted for MP3V5050GC6U?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MP3V5050GC6U transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MP3V5050GC6U?
MP3V5050GC6U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MP3V5050GC6U order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MP3V5050GC6U?
For technical support, including MP3V5050GC6U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MP3V5050GC6U requirements.
6.How does Aetrix verify that MP3V5050GC6U is sourced from the original manufacturer or authorized distributors?
All MP3V5050GC6U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MP3V5050GC6U meets industry standards.
7.What is the process for return or replacement of MP3V5050GC6U?
All MP3V5050GC6U units undergo pre-shipment inspection (PSI). If there is an issue with MP3V5050GC6U, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MP3V5050GC6U part is unused and in its original packaging.
Return procedure for MP3V5050GC6U:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MP3V5050GC6U Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…