NXP Semiconductors MP3V5100GC6U

Part No.:
MP3V5100GC6U
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
8-SMD, Gull Wing, Top Port
Datasheet:
AetrixMP3V5100GC6U.pdf
Description:
SENSOR 7.25PSI 0.13" 2.82V
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:2,300

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MP3V5100GC6U from Freescale Semiconductor is a gauge-pressure sensor IC with on-chip signal conditioning, temperature compensation, and factory calibration. It delivers a ratiometric 0.1–3.1 V analog output over 0–100 kPa (0–14.5 psi), operates from 2.7–3.3 V supply, draws ≤10 mA, and achieves ±2.5% full-scale accuracy across –40°C to +125°C. It is used in patient monitoring and pump/motor control systems requiring stable, low-power pressure sensing.

For engineers reviewing the MP3V5100GC6U datasheet, MP3V5100GC6U pinout, MP3V5100GC6U application, or MP3V5100GC6U equivalent, this page provides verified package mapping (Case 482A-01), confirmed gauge configuration, validated transfer function (VOUT = VS × (0.009 × P + 0.06)), and real-world application constraints including dry-air media requirement and decoupling circuit necessity.

Technical Context

The MP3V5100GC6U integrates a patented silicon shear-stress strain gauge with thin-film metallization and bipolar processing on a monolithic die. Its on-chip circuitry includes two gain stages, temperature compensation, offset calibration, and ground reference shift - all optimized for microcontroller A/D interfacing.

It is strictly a gauge-pressure device (P1 referenced to ambient) with no differential or absolute variants supported in this exact part number. Pins 1, 5, 6, 7, and 8 are NC; only pins 2 (VOUT), 3 (GND), and 4 (VS) are functional. The transfer function is linear and ratiometric, with error budget dominated by linearity, TCOffset, and TCSpan contributions.

Key Specifications

ParameterValue and Actual Design Meaning
Pressure Range0–100 kPa gauge; supports medical and industrial pressure monitoring up to 14.5 psi without saturation.
Output Voltage0.1–3.1 V (ratiometric to VS); directly compatible with 3.0 V ADC references without scaling.
Supply Voltage2.7–3.3 Vdc; enables direct connection to common 3.0 V microcontroller rails with ±10% tolerance.
Accuracy±2.5% of full-scale span (±2.5 kPa max error); specified over 0–85°C operating range.
Response Time1.0 ms (10%–90%); suitable for dynamic pressure events like pump cycling or respiratory waveform capture.
Warm-Up Time20 ms; ensures stable output within one microcontroller sampling interval after power-on.
Sensitivity27 mV/kPa; yields ~2.7 V full-scale output at 100 kPa with 3.0 V supply, matching typical ADC input ranges.

Pinout & Package

MP3V5100GC6U uses thermoplastic (PPS) surface-mount Small Outline Package Case 482A-01 (8-pin, 12.7 mm × 10.79 mm × 3.17 mm). Pins 1, 5, 6, 7, and 8 are No Connects; only three terminals are active.

Pin/TerminalCircuit RoleDesign Meaning
Pin 2VOUTAnalog output signal; 0.1–3.1 V ratiometric voltage proportional to applied gauge pressure.
Pin 3GNDAnalog ground reference; must be tied to system AGND with low-impedance path to minimize noise coupling.
Pin 4VSSupply input; requires 1.0 μF + 0.01 μF decoupling per Figure 3 to meet accuracy spec.

Key Features

FeatureDesign Value
On-chip temperature compensationEliminates need for external thermistor or software correction across –40°C to +125°C ambient.
Factory-calibrated offset and spanReduces system-level calibration effort; enables plug-and-play integration into embedded A/D systems.
Patented silicon shear-stress strain gaugeDelivers superior long-term stability and reduced hysteresis vs. conventional piezoresistive elements.
Gauge pressure configuration (P1 side)Single-port design with port attached to P1 side; simplifies mechanical mounting in vented applications.
Ratiometric outputOutput scales linearly with supply voltage; rejects VS drift when using same reference for ADC and sensor.

Applications

Patient MonitoringPump/Motor Control

Use Scenario: Continuous non-invasive blood pressure or respiratory airway pressure measurement in portable clinical devices.

IC Role / Device Role / Timing Role: Gauge-pressure transducer providing calibrated analog voltage to MCU ADC for waveform digitization and alarm triggering.

Use Value: ±2.5% accuracy and 1 ms response enable reliable detection of systolic/diastolic transitions and breath cycle timing.

Use Scenario: Closed-loop feedback for centrifugal pump speed regulation based on outlet pressure in HVAC or fluid handling systems.

IC Role / Device Role / Timing Role: Primary pressure feedback element feeding real-time analog signal to PID controller running on microcontroller.

Use Value: Ratiometric output and 20 ms warm-up allow immediate post-power-on control without calibration delay.

Process ControlPressure Switching

Use Scenario: Monitoring tank level or filter clogging via differential pressure drop across a fixed orifice in industrial automation lines.

IC Role / Device Role / Timing Role: Analog front-end sensor converting pressure into voltage for threshold comparison and PLC interface.

Use Value: 0.1 V minimum output prevents false zero-pressure triggers during low-pressure transients.

Use Scenario: Replacing electromechanical pressure switches in appliance safety interlocks (e.g., washing machine lid lock, boiler overpressure cutoff).

IC Role / Device Role / Timing Role: Solid-state pressure threshold detector with programmable logic-level decision via MCU firmware.

Use Value: 2.5 kPa maximum pressure error ensures repeatable trip points across temperature and lifetime.

Equivalent & Alternatives

The following parts are listed as comparable options for similar gauge-pressure sensing applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
MPX5100GPSame MPX5100 series; tray-packaged (Case 1369-01), identical electrical specs but different footprint and thermal mass.Requires PCB redesign due to larger 1369 package; better suited for manual assembly or high-reliability test fixtures.Select MPX5100GP only if board space allows larger outline and tray handling is preferred over tape-and-reel.
MP3V5050GSame family, lower range (0–50 kPa); 0.2–2.8 V output, same accuracy and package (482A).Half-pressure range limits use to low-pressure applications (e.g., airflow, vacuum assist); not interchangeable without firmware gain adjustment.Choose MP3V5050G only when system pressure never exceeds 50 kPa and tighter resolution at low end is required.

Compared with MPX5100GP and MP3V5050G, the MP3V5100GC6U offers optimal balance of 100 kPa range, compact 482A tape-and-reel packaging, and production-ready calibration - making it the default choice for automated SMT lines targeting mid-range gauge pressure sensing.

Availability

MP3V5100GC6U is available at Aetrix Electronics and suitable for patient monitoring, pump/motor control, and process control applications requiring stable component supply, consistent calibration, and RoHS-compliant surface-mount packaging.

Supply support for MP3V5100GC6U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Freescale Semiconductor (now part of NXP Semiconductors) was a leading designer of embedded processors and analog sensors, known for automotive, industrial, and medical-grade mixed-signal ICs.

The MP3V5100GC6U belongs to Freescale's integrated silicon pressure sensor product line, engineered specifically for microcontroller-based systems needing calibrated, low-power, surface-mount pressure transduction with minimal external components.

FAQ

What pressure type does MP3V5100GC6U measure?

The MP3V5100GC6U measures gauge pressure - meaning it reports pressure relative to ambient atmospheric pressure. Its single port (P1) is exposed to the measured medium, while the internal reference cavity is vented to atmosphere. This configuration is confirmed in the "Pressure (P1)/Vacuum (P2) Side Identification Table" and applies exclusively to the GC6U variant; it does not support differential or absolute modes. The MP3V5100GC6U must be mounted with the port side facing the pressure source and unobstructed airflow around the case.

What is the recommended decoupling network for MP3V5100GC6U?

The MP3V5100GC6U requires a specific decoupling network on its VS pin to meet published accuracy specifications: a 1.0 μF bulk capacitor, a 0.01 μF ceramic capacitor, and a 470 pF capacitor placed as close as possible to pins 3 (GND) and 4 (VS). This configuration is shown in Figure 3 of the official datasheet and is mandatory - omitting or substituting these values results in degraded noise immunity and increased error beyond ±2.5% VFSS. The MP3V5100GC6U will operate without it but fails to meet guaranteed performance.

Can MP3V5100GC6U be used with media other than dry air?

No - the MP3V5100GC6U is qualified and characterized exclusively for use with dry air as the pressure medium. Exposure to moisture, oils, solvents, or corrosive gases may degrade the fluorosilicone gel encapsulant, damage wire bonds, or cause long-term drift in offset and span. Freescale explicitly states that "media other than dry air may have adverse effects on sensor performance and long-term reliability." For non-dry-air applications, consult NXP (ex-Freescale) for qualified alternatives; the MP3V5100GC6U must not be deployed in such environments without formal media compatibility validation.

What is the meaning of "C6U" in MP3V5100GC6U?

The "C6U" suffix in MP3V5100GC6U denotes two specific attributes: "C6" indicates the Small Outline Package (Case 482A-01), and "U" specifies tape-and-reel packaging format (as opposed to "T1" for tape-and-reel with different reel specs or "P" for trays). This coding is defined in the Ordering Information table and confirms the device is supplied in 482A outline with standard carrier tape - critical for SMT placement equipment compatibility. The MP3V5100GC6U is not functionally distinct from MP3V5100GC6T1; only packaging differs.

Does MP3V5100GC6U require external calibration during system integration?

No - the MP3V5100GC6U is fully calibrated at the factory for offset, full-scale output, and temperature coefficients across 0–85°C. Its on-chip temperature compensation and signal conditioning eliminate the need for system-level calibration in most applications. However, final system validation is still required: users must verify linearity, warm-up behavior, and long-term stability under actual operating conditions. While the MP3V5100GC6U reduces calibration burden significantly, it does not remove the need for end-of-line functional testing per IEC 60601 or ISO 13485 where applicable.

MP3V5100GC6U Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MP3V5100
Package/Case:
8-SMD, Gull Wing, Top Port
Packaging:
Tube
Product Status:
Obsolete
Applications:
Board Mount
Pressure Type:
Vacuum
Operating Pressure:
-7.25PSI (-50kPa)
Output Type:
Analog Voltage
Output:
0.06 V ~ 2.82 V
Accuracy:
±2.5%
Voltage - Supply:
2.7V ~ 3.3V
Port Size:
Male - 0.13" (3.17mm) Tube
Port Style:
Barbless
Features:
Amplified Output, Temperature Compensated
Termination Style:
Gull Wing
Maximum Pressure:
-58.02PSI (-400kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
-

MP3V5100GC6U FAQ

1.How can I place an order for MP3V5100GC6U through Aetrix?

Please submit a Request for Quotation (RFQ) for MP3V5100GC6U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MP3V5100GC6U reliable?

The price and inventory of MP3V5100GC6U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MP3V5100GC6U is usually 5 days.

3.What payment methods are accepted for MP3V5100GC6U?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MP3V5100GC6U transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MP3V5100GC6U?

MP3V5100GC6U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MP3V5100GC6U order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MP3V5100GC6U?

For technical support, including MP3V5100GC6U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MP3V5100GC6U requirements.

6.How does Aetrix verify that MP3V5100GC6U is sourced from the original manufacturer or authorized distributors?

All MP3V5100GC6U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MP3V5100GC6U meets industry standards.

7.What is the process for return or replacement of MP3V5100GC6U?

All MP3V5100GC6U units undergo pre-shipment inspection (PSI). If there is an issue with MP3V5100GC6U, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MP3V5100GC6U part is unused and in its original packaging.

Return procedure for MP3V5100GC6U:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MP3V5100GC6U Tags

  • MP3V5100GC6U
  • MP3V5100GC6U PDF
  • MP3V5100GC6U Datasheet
  • MP3V5100GC6U Specifications
  • MP3V5100GC6U Images
  • NXP Semiconductors
  • NXP Semiconductors MP3V5100GC6U
  • Buy MP3V5100GC6U
  • MP3V5100GC6U Price
  • MP3V5100GC6U Distributor
  • MP3V5100GC6U Supplier
  • MP3V5100GC6U Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER