NXP Semiconductors MP3V5100GP

Part No.:
MP3V5100GP
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
8-SMD, Gull Wing, Side Port
Datasheet:
AetrixMP3V5100GP.pdf
Description:
SENSOR 7.25PSI 0.13" 2.82V 8SOP
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:2,250

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MP3V5100GP from Freescale Semiconductor is a fully signal-conditioned, temperature-compensated, and factory-calibrated silicon piezoresistive pressure sensor in a thermoplastic (PPS) surface-mount package. It delivers a ratiometric 0.1–3.1 V analog output over a 0–100 kPa (0–14.5 psi) gauge pressure range, with ±2.5% full-scale accuracy across 0°C to 85°C, and is designed for direct interface to microcontroller A/D inputs in medical and industrial sensing systems.

For engineers reviewing the MP3V5100GP datasheet, MP3V5100GP pinout, MP3V5100GP application, or MP3V5100GP equivalent, this page provides verified technical context, validated pin functions, real-world use scenarios, and confirmed alternative options for pressure-sensing designs requiring stable analog output, low warm-up time (≤20 ms), and minimal offset drift (±0.5% VFSS after 1000-hour stress).

Technical Context

The MP3V5100GP integrates a patented silicon shear-stress strain gauge with on-chip bipolar signal conditioning, including two-stage gain amplification and ground-reference shift circuitry. Its ratiometric transfer function - Vout = VS × (0.009 × P + 0.06) - ensures output scaling directly proportional to supply voltage (2.7–3.3 Vdc), enabling robust performance without external reference components.

It operates as a gauge-pressure transducer with P1 (pressure side) and P2 (vacuum/reference side) ports physically isolated by fluorosilicone gel; pins 1, 5, 6, 7, and 8 are no-connects in the Case 1369-01 small-outline package. The device requires the decoupling network shown in Figure 3 (1.0 μF / 0.01 μF / 470 pF) to meet specified accuracy and response time (1.0 ms typical).

Key Specifications

ParameterValue and Actual Design Meaning
Pressure Range0–100 kPa gauge; supports medical pump control and HVAC differential monitoring at standard atmospheric reference.
Output Voltage0.1–3.1 Vdc ratiometric; scales linearly with supply voltage, eliminating need for precision voltage reference in MCU-based systems.
Accuracy±2.5% VFSS over 0°C to 85°C; includes linearity, temp hysteresis, pressure hysteresis, TcSpan, and TcOffset contributions.
Supply Voltage2.7–3.3 Vdc; enables direct connection to 3.0 V MCU rails without LDO regulation.
Response Time1.0 ms (10%–90%); suitable for fast-cycling applications like respiratory flow sensing and solenoid valve feedback.
Warm-Up Time≤20 ms; meets real-time system startup requirements in portable patient monitors and battery-powered instrumentation.
Offset Stability±0.5% VFSS after 1000-hr pulsed pressure/thermal cycling; validates long-term reliability in continuous-use industrial controls.

Pinout & Package

MP3V5100GP uses Case 1369-01 - a thermoplastic (PPS) small-outline surface-mount package with 8 leads, 1.27 mm pitch, and dimensions 7.11 × 7.62 × 3.17 mm (L × W × H). Pins 1, 5, 6, 7, and 8 are internally unconnected and must remain floating per datasheet Figure 1.

Pin/TerminalCircuit RoleDesign Meaning
VS (Pin 2)Supply InputAccepts 2.7–3.3 Vdc; powers internal amplifier chain and compensation circuitry; ratiometric output depends on this rail.
VOUT (Pin 3)Analog OutputProvides 0.1–3.1 Vdc proportional to applied pressure; requires 470 pF capacitor to GND per Figure 3 for noise suppression.
GND (Pin 4)Ground ReferenceReturn path for supply and output; must be low-impedance and separate from digital ground to avoid noise coupling.

Key Features

FeatureDesign Value
On-chip temperature compensationEliminates need for external thermistor networks or software calibration tables across –40°C to +125°C operating range.
Patented silicon shear-stress strain gaugeDelivers superior long-term stability and reduced hysteresis vs. conventional piezoresistive elements.
Fluorosilicone gel isolationProtects die and wire bonds from moisture and chemical exposure while transmitting pressure accurately to diaphragm.
Ratiometric output architectureEnables direct ADC interfacing with 3.0 V microcontrollers without external voltage references or gain trimming.

Applications

Process ControlPatient Monitoring

Use Scenario: Monitoring fluid pressure in closed-loop chemical dosing systems where precise 0–100 kPa range detection prevents overfeed or underfeed.

IC Role / Device Role / Timing Role: Primary analog pressure transducer providing calibrated voltage output to PLC analog input module.

Use Value: ±2.5% VFSS accuracy and ±0.5% VFSS offset stability ensure consistent batch-to-batch repeatability over 1000+ hours of operation.

Use Scenario: Measuring airway pressure in portable ventilators and CPAP devices during inhalation/exhalation cycles.

IC Role / Device Role / Timing Role: Gauge-pressure sensor feeding real-time pressure data to ARM Cortex-M4 MCU for breath-triggered actuation.

Use Value: 1.0 ms response time and ≤20 ms warm-up enable sub-second pressure tracking required for adaptive respiratory support algorithms.

Pump/Motor ControlPressure Switching

Use Scenario: Detecting head pressure buildup in centrifugal water pumps to prevent dry-run damage or thermal overload.

IC Role / Device Role / Timing Role: Analog feedback element in motor drive control loop, triggering speed reduction or shutdown at preset thresholds.

Use Value: Ratiometric 0.1–3.1 V output allows direct mapping to 12-bit ADC without scaling resistors or op-amp buffers.

Use Scenario: Replacing mechanical pressure switches in HVAC duct static pressure monitoring for fan speed modulation.

IC Role / Device Role / Timing Role: Solid-state pressure threshold detector interfaced to comparator or MCU GPIO with configurable hysteresis.

Use Value: Thermoplastic PPS package withstands repeated thermal cycling in commercial building environments without solder joint fatigue.

Equivalent & Alternatives

The following parts are listed as comparable options for similar gauge-pressure transducer applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
MPX5100GPSame Case 1369-01 package, identical 0–100 kPa range and ratiometric output, but older revision with wider offset tolerance (0.1–0.3 V vs. 0.11–0.25 V).Lacks updated temperature hysteresis spec; suitable only where legacy qualification suffices.Select MPX5100GP only if backward compatibility with prior design documentation is required.
SPX3100-001-DDual-port differential variant with same 0–100 kPa range, but requires P1/P2 differential configuration and lacks gauge reference port sealing.Designed for bidirectional flow measurement; not drop-in for single-sided gauge applications like MP3V5100GP.Choose SPX3100-001-D only when differential pressure sensing (e.g., filter clogging detection) is needed instead of absolute/gauge reference.

Compared with MPX5100GP and SPX3100-001-D, the MP3V5100GP offers tighter factory-calibrated offset (0.11–0.25 V), improved long-term offset stability (±0.5% VFSS), and optimized fluorosilicone encapsulation for enhanced media compatibility - making it preferred for new medical and industrial designs demanding higher confidence in initial calibration and field longevity.

Availability

MP3V5100GP is available at Aetrix Electronics and suitable for process control, patient monitoring, and pump/motor control applications requiring stable component supply, traceable sourcing, and lifecycle continuity management.

Supply support for MP3V5100GP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Freescale Semiconductor (now part of NXP Semiconductors) was a leading designer of embedded processors and sensors, known for high-reliability analog and mixed-signal ICs targeting automotive, industrial, and medical markets.

The MP3V5100GP belongs to Freescale's integrated silicon pressure sensor product line, engineered specifically for microcontroller-based systems needing calibrated, low-drift analog pressure feedback without external signal conditioning.

FAQ

What is the pressure type supported by the MP3V5100GP?

The MP3V5100GP is a gauge-pressure sensor: it measures pressure relative to ambient atmospheric pressure using a dedicated reference port (P2). Its datasheet confirms single-port gauge configuration with P1 as the pressure side and P2 as the vacuum/reference side, sealed via fluorosilicone gel. This makes MP3V5100GP appropriate for applications like HVAC static pressure monitoring and respiratory airway sensing where atmospheric reference is inherent.

Does the MP3V5100GP require external calibration after soldering?

No, the MP3V5100GP does not require external calibration after soldering. It is factory-calibrated across temperature and pressure ranges, with on-chip temperature compensation and signal conditioning ensuring ±2.5% VFSS accuracy from 0°C to 85°C. The MP3V5100GP's offset and full-scale span are trimmed during manufacturing, and its ratiometric output eliminates dependency on external voltage references - enabling plug-and-play integration into MCU-based systems.

What is the maximum pressure the MP3V5100GP can withstand without damage?

The MP3V5100GP has a maximum pressure rating of 400 kPa (58 psi) for P1 > P2, as specified in Table 2 of its datasheet. Exceeding this value may cause permanent damage or degradation. While its operational range is 0–100 kPa, the device includes mechanical overpressure margin for transient spikes - critical in pump control and compressor monitoring where pressure surges occur. Always maintain P1 > P2 to preserve sensor integrity.

Can the MP3V5100GP operate from a 5 V supply?

No, the MP3V5100GP cannot operate from a 5 V supply. Its absolute maximum supply voltage is 3.3 Vdc, and recommended operation is strictly 2.7–3.3 Vdc per Table 1. Applying 5 V will exceed the maximum ratings and likely cause irreversible damage. For 5 V systems, an LDO or DC-DC converter must step down to 3.0 V before powering the MP3V5100GP - which also preserves its ratiometric accuracy and avoids violating the 10 mA max supply current limit.

Is the MP3V5100GP compatible with wet or corrosive media?

The MP3V5100GP is qualified for use with dry air as the pressure medium; Freescale explicitly states that other media may adversely affect performance and long-term reliability. Its fluorosilicone gel protects the die, but compatibility with liquids, oils, or aggressive gases is not guaranteed. For MP3V5100GP deployments involving non-dry-air media, consult NXP's application engineering team for media-specific validation - especially in medical fluid sensing or chemical processing applications.

MP3V5100GP Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MP3V5100
Package/Case:
8-SMD, Gull Wing, Side Port
Packaging:
Tray
Product Status:
Obsolete
Applications:
Board Mount
Pressure Type:
Vacuum
Operating Pressure:
-7.25PSI (-50kPa)
Output Type:
Analog Voltage
Output:
0.06 V ~ 2.82 V
Accuracy:
±2.5%
Voltage - Supply:
2.7V ~ 3.3V
Port Size:
Male - 0.13" (3.17mm) Tube
Port Style:
Barbed
Features:
Amplified Output, Temperature Compensated
Termination Style:
Gull Wing
Maximum Pressure:
-58.02PSI (-400kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
8-SOP

MP3V5100GP FAQ

1.How can I place an order for MP3V5100GP through Aetrix?

Please submit a Request for Quotation (RFQ) for MP3V5100GP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MP3V5100GP reliable?

The price and inventory of MP3V5100GP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MP3V5100GP is usually 5 days.

3.What payment methods are accepted for MP3V5100GP?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MP3V5100GP transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MP3V5100GP?

MP3V5100GP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MP3V5100GP order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MP3V5100GP?

For technical support, including MP3V5100GP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MP3V5100GP requirements.

6.How does Aetrix verify that MP3V5100GP is sourced from the original manufacturer or authorized distributors?

All MP3V5100GP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MP3V5100GP meets industry standards.

7.What is the process for return or replacement of MP3V5100GP?

All MP3V5100GP units undergo pre-shipment inspection (PSI). If there is an issue with MP3V5100GP, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MP3V5100GP part is unused and in its original packaging.

Return procedure for MP3V5100GP:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MP3V5100GP Tags

  • MP3V5100GP
  • MP3V5100GP PDF
  • MP3V5100GP Datasheet
  • MP3V5100GP Specifications
  • MP3V5100GP Images
  • NXP Semiconductors
  • NXP Semiconductors MP3V5100GP
  • Buy MP3V5100GP
  • MP3V5100GP Price
  • MP3V5100GP Distributor
  • MP3V5100GP Supplier
  • MP3V5100GP Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER