Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

NXP Semiconductors MPVZ4006GW7U

Part No.:
MPVZ4006GW7U
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
8-DIP Module
Datasheet:
AetrixMPVZ4006GW7U.pdf
Description:
SENSOR 0.87PSIG 0.22" 4.6V
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:138

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MPVZ4006GW7U from Freescale Semiconductor is a fully integrated, temperature-compensated and factory-calibrated silicon piezoresistive pressure sensor with analog output, designed for differential or gauge pressure measurement in the 0–6 kPa range. It delivers a ratiometric 0.3–4.6 V output at 5 V supply, features ±2.46% full-scale accuracy with auto-zero, and uses a durable thermoplastic (PPS) package with through-hole mounting (Case 1560-02). It is deployed in respiratory equipment and appliance liquid-level sensing.

For engineers reviewing the MPVZ4006GW7U datasheet, MPVZ4006GW7U pinout, MPVZ4006GW7U application, or MPVZ4006GW7U equivalent, key selection considerations include its 6 kPa full-scale range, 5 V ratiometric excitation, ±2.46% VFSS accuracy with auto-zero, through-hole small-outline package (Case 1560-02), and compatibility with microcontroller A/D inputs without external signal conditioning.

Technical Context

The MPVZ4006GW7U integrates micromachined silicon sensing elements with on-chip thin-film temperature compensation, gain stages, and offset correction circuitry - all monolithically fabricated. Its transfer function is Vout = VS × [(0.1533 × P) + 0.053], where P is pressure in kPa and VS is supply voltage.

It operates exclusively with dry air as pressure media; non-air media may degrade long-term reliability. The device requires auto-zeroing post-installation to achieve specified ±2.46% VFSS accuracy, due to sensitivity to mechanical stress and mounting orientation.

Key Specifications

ParameterValue and Actual Design Meaning
Pressure Range0–6 kPa (0–612 mm H₂O); defines usable differential/gauge pressure span for accurate linear output.
Output Voltage Range0.3–4.6 V at VS = 5.0 V; ratiometric analog output directly compatible with 5 V microcontroller ADCs.
Accuracy±2.46% VFSS with auto-zero; error budget includes linearity, TcSpan, TcOffset, hysteresis, and stability after thermal/pressure cycling.
Supply Voltage4.75–5.25 Vdc; operation outside this range invalidates accuracy and may damage device.
Operating Temperature+10°C to +60°C; full performance specification applies only within this ambient range.
Max Pressure Rating75 kPa; absolute maximum differential pressure before risk of permanent damage.
Sensitivity766 mV/kPa typical; determines resolution and signal-to-noise ratio for given pressure step size.

Pinout & Package

MPVZ4006GW7U uses a through-hole small-outline package (Case 1560-02), featuring a stainless steel cap and vertical port attachment for industrial tubing. Pin 1 is identified by a notch in the lead frame; pins 1, 5, 6, 7, and 8 are internal no-connects and must remain unconnected.

Pin/TerminalCircuit RoleDesign Meaning
1No ConnectInternal device connection; electrically isolated from external circuitry.
2VSPositive supply input (4.75–5.25 Vdc); powers all on-chip circuitry including sensor and signal conditioning.
3GndAnalog ground reference; must be low-impedance and shared with microcontroller ground for ratiometric accuracy.
4VoutAnalog output (0.3–4.6 V); connects directly to ADC input; requires 0.01 µF decoupling per datasheet Figure 3.
5–8No ConnectInternally bonded but not routed externally; floating terminals must not be soldered or grounded.

Key Features

FeatureDesign Value
On-chip temperature compensationEliminates need for external thermistor networks or software temperature correction over +10°C to +60°C.
Factory calibration and auto-zero supportEnables ±2.46% VFSS accuracy post-mounting via simple zero-offset subtraction in firmware.
Durable PPS thermoplastic packageWithstands mechanical stress and humidity in appliance and healthcare enclosures without hermetic sealing.
Ratiometric 5 V operationOutput scales linearly with supply voltage, allowing direct interface to 5 V MCU ADCs without reference voltage scaling.
Differential/gauge configurationSupports both differential pressure (P1 > P2) and single-ended gauge measurements using atmospheric reference.

Applications

Washing Machine Water Level ControlRespiratory Therapy Devices

Use Scenario: Detects water column height via air pressure in sealed tube connected to drum sump.

IC Role / Device Role / Timing Role: Gauge pressure transducer converting hydrostatic head into calibrated analog voltage.

Use Value: Enables precise fill-level detection across temperature variations without recalibration, supporting energy-efficient cycle control.

Use Scenario: Monitors airway pressure in CPAP and ventilator systems during patient inhalation/exhalation cycles.

IC Role / Device Role / Timing Role: High-stability differential pressure sensor measuring sub-kPa pressure differentials with fast response.

Use Value: Delivers ±2.46% VFSS accuracy after auto-zero, critical for safe pressure delivery and alarm triggering in life-support equipment.

Industrial Appliance Liquid Level SensingHealthcare Nebulizer Flow Monitoring

Use Scenario: Measures detergent or rinse aid volume in commercial dishwashers using air-coupled pressure sensing.

IC Role / Device Role / Timing Role: Low-range analog pressure interface with built-in signal conditioning for direct MCU integration.

Use Value: Reduces BOM count by eliminating external op-amps, ADC references, and temperature sensors required by raw bridge sensors.

Use Scenario: Tracks airflow-induced pressure drop across nebulizer chamber to infer aerosol generation status.

IC Role / Device Role / Timing Role: Analog front-end sensor providing real-time pressure feedback for closed-loop flow regulation.

Use Value: Maintains consistent drug delivery by detecting clogging or low-flow conditions via calibrated 0–6 kPa output span.

Equivalent & Alternatives

The following parts are listed as comparable options for similar pressure transducer applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
MPXV5004DP0–4 kPa range, dual-port differential, 0.2–4.8 V output, same Case 482B-03 through-hole package.Limited to lower full-scale pressure; unsuitable for 6 kPa applications like high-head washing machines.Select MPXV5004DP only when system pressure never exceeds 4 kPa and dual-port differential configuration is required.
MPVZ5004GW7U0–4 kPa range, same Case 1560-02 package, ±2.46% VFSS accuracy, identical pinout and auto-zero requirement.Lower full-scale range reduces resolution for 6 kPa use cases; output spans only 0.3–3.9 V at 5 V supply.Choose MPVZ5004GW7U if design targets ≤4 kPa pressure and shares PCB layout with MPVZ4006GW7U for manufacturing flexibility.

Compared with MPXV5004DP and MPVZ5004GW7U, the MPVZ4006GW7U uniquely supports the full 6 kPa range while retaining identical through-hole mounting, auto-zero workflow, and accuracy spec - making it the only validated option for applications requiring up to 612 mm H₂O head pressure.

Availability

MPVZ4006GW7U is available at Aetrix Electronics and suitable for washing machine water level control, respiratory therapy devices, and industrial appliance liquid level sensing requiring stable component supply across extended production lifecycles.

Supply support for MPVZ4006GW7U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Freescale Semiconductor (now part of NXP Semiconductors) is a fabless semiconductor company specializing in embedded processing, analog, and sensor solutions for automotive, industrial, and consumer markets.

The MPVZ series was developed as a family of integrated pressure transducers targeting cost-sensitive, high-volume applications in appliances and portable medical devices - emphasizing factory calibration, minimal external components, and robust packaging for non-hermetic environments.

FAQ

What is the full-scale pressure range of the MPVZ4006GW7U?

The MPVZ4006GW7U has a full-scale pressure range of 0–6 kPa (0–612 mm H₂O), specified for differential or gauge pressure measurement. This range is fixed and cannot be extended beyond 6 kPa without risking saturation or accuracy degradation. The MPVZ4006GW7U output saturates outside this range, and maximum rated pressure is 75 kPa for survival only.

Does the MPVZ4006GW7U require external signal conditioning?

No, the MPVZ4006GW7U does not require external signal conditioning. It integrates on-chip temperature compensation, calibration, and two-stage gain amplification. Its 0.3–4.6 V ratiometric analog output is designed to connect directly to a microcontroller's A/D input, provided proper 0.01 µF decoupling is used per the recommended circuit in Freescale Application Note AN1646.

What is the significance of "auto-zero" for the MPVZ4006GW7U?

Auto-zero for the MPVZ4006GW7U refers to a firmware-based calibration step where the zero-pressure output reading is captured after mechanical installation and subtracted from subsequent measurements. This compensates for mounting-induced stress and orientation effects. The MPVZ4006GW7U achieves ±2.46% VFSS accuracy only when auto-zero is implemented; without it, accuracy degrades to ±5.0% VFSS.

Which package type does the MPVZ4006GW7U use, and how is pin 1 identified?

The MPVZ4006GW7U uses a through-hole small-outline package (Case 1560-02) with vertical port attachment. Pin 1 is identified by a physical notch in the lead frame, located adjacent to the first pin. Pins 1, 5, 6, 7, and 8 are internal no-connects and must remain unconnected in the PCB layout.

Can the MPVZ4006GW7U be used with pressure media other than dry air?

The MPVZ4006GW7U is qualified and characterized for use with dry air only. Freescale explicitly states that other media may adversely affect long-term reliability and sensor performance. Media compatibility testing for non-air fluids or gases must be requested directly from NXP (formerly Freescale), and no validation data for alternative media is included in the MPVZ4006GW7U datasheet.

MPVZ4006GW7U Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MPVZ4006G
Package/Case:
8-DIP Module
Packaging:
Tube
Product Status:
Active
Applications:
Board Mount
Pressure Type:
Vented Gauge
Operating Pressure:
0.87PSI (6kPa)
Output Type:
Analog Voltage
Output:
0.3 V ~ 4.6 V
Accuracy:
-
Voltage - Supply:
4.75V ~ 5.25V
Port Size:
Male - 0.22" (5.59mm) Tube
Port Style:
Barbless
Features:
Temperature Compensated
Termination Style:
PC Pin
Maximum Pressure:
10.88PSI (75kPa)
Operating Temperature:
10°C ~ 60°C
Grade:
-
Qualification:
-
Mounting Type:
Through Hole
Supplier Device Package:
-

MPVZ4006GW7U FAQ

1.How can I place an order for MPVZ4006GW7U through Aetrix?

Please submit a Request for Quotation (RFQ) for MPVZ4006GW7U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MPVZ4006GW7U reliable?

The price and inventory of MPVZ4006GW7U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPVZ4006GW7U is usually 5 days.

3.What payment methods are accepted for MPVZ4006GW7U?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPVZ4006GW7U transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MPVZ4006GW7U?

MPVZ4006GW7U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MPVZ4006GW7U order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MPVZ4006GW7U?

For technical support, including MPVZ4006GW7U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPVZ4006GW7U requirements.

6.How does Aetrix verify that MPVZ4006GW7U is sourced from the original manufacturer or authorized distributors?

All MPVZ4006GW7U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPVZ4006GW7U meets industry standards.

7.What is the process for return or replacement of MPVZ4006GW7U?

All MPVZ4006GW7U units undergo pre-shipment inspection (PSI). If there is an issue with MPVZ4006GW7U, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MPVZ4006GW7U part is unused and in its original packaging.

Return procedure for MPVZ4006GW7U:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MPVZ4006GW7U Tags

  • MPVZ4006GW7U
  • MPVZ4006GW7U PDF
  • MPVZ4006GW7U Datasheet
  • MPVZ4006GW7U Specifications
  • MPVZ4006GW7U Images
  • NXP Semiconductors
  • NXP Semiconductors MPVZ4006GW7U
  • Buy MPVZ4006GW7U
  • MPVZ4006GW7U Price
  • MPVZ4006GW7U Distributor
  • MPVZ4006GW7U Supplier
  • MPVZ4006GW7U Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER