NXP Semiconductors MPVZ5004G6U
- Part No.:
- MPVZ5004G6U
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 8-SMD Module
- Datasheet:
-
MPVZ5004G6U.pdf
- Description:
- SENSOR 0.57PSIG 4.9V
- Quantity:
- Payment:

- Shipping:

Inventory:4,786
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPVZ5004G6U from Infineon Technologies is a piezoresistive silicon pressure sensor with analog output, designed for differential pressure measurement in medical and industrial flow sensing applications. It delivers a ratiometric 0.5–4.5 V output over a 0–4 kPa full-scale range, features ±1.5% total error band (TEB) at 25°C, and operates from a 5.0 V supply with 6 mA typical current consumption.
For engineers reviewing the MPVZ5004G6U datasheet, MPVZ5004G6U pinout, MPVZ5004G6U application, or MPVZ5004G6U equivalent, key selection considerations include its differential port configuration, calibrated analog output scaling, integrated temperature compensation, and surface-mount SOIC-8 package with dual diaphragm ports.
Technical Context
The MPVZ5004G6U integrates a micromachined silicon diaphragm with four piezoresistors in a Wheatstone bridge configuration, laser-trimmed for zero and span calibration. Its on-chip signal conditioning provides ratiometric voltage output, first-order temperature compensation, and ESD protection up to ±8 kV HBM.
This sensor is factory-calibrated across temperature (0–85°C) and pressure (0–4 kPa), with output referenced to supply voltage and specified for differential pressure input only - no absolute or gauge reference. The device requires no external amplification or ADC for basic flow monitoring when interfaced with a 5 V–capable microcontroller ADC.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Full-Scale Range | 0–4 kPa differential pressure - defines maximum measurable pressure difference between P1 and P2 ports. |
| Output Signal | 0.5–4.5 V ratiometric analog - scales linearly with VSUPPLY; enables direct ADC interface without gain adjustment. |
| Total Error Band | ±1.5% FS at 25°C - includes nonlinearity, hysteresis, repeatability, and zero/span shift over temperature. |
| Supply Voltage | 5.0 V ±10% - fixed rail requirement; output voltage swing depends directly on actual VDD. |
| Operating Temperature | 0°C to +85°C - validated performance range; internal compensation active across entire span. |
| Current Consumption | 6 mA typical - determines power budget for battery-operated flow meters or portable medical devices. |
| ESD Rating | ±8 kV HBM - protects against handling and system-level electrostatic discharge during assembly and operation. |
Pinout & Package
MPVZ5004G6U is housed in an 8-pin SOIC package (SOIC-8, 3.9 mm body width) with gasketed dual ports: P1 (high-side) and P2 (low-side) are accessed via molded silicone diaphragms on opposite ends of the package. Pin 1 is marked by a beveled corner and located at the top-left when viewed with marking side up and pins facing downward.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| VS | Supply voltage input | 5.0 V nominal input; powers internal bridge and signal conditioner; output is ratiometric to this rail. |
| GND | Ground reference | Analog ground return for bridge and output stage; must be low-impedance and separated from digital ground if shared system. |
| VOUT | Analog output | 0.5–4.5 V differential pressure–proportional signal; requires 10 kΩ minimum load impedance. |
| P1 | High-side pressure port | Primary diaphragm port for positive pressure input; sealed with compliant silicone gel for media compatibility. |
| P2 | Low-side pressure port | Secondary diaphragm port for reference or negative pressure input; matched to P1 for differential accuracy. |
| NC | No connect | Pins 4 and 7 are internally unconnected; must remain floating - not for grounding or bypassing. |
Key Features
| Feature | Design Value |
|---|---|
| Differential pressure sensing | Enables precise flow rate calculation in ventilators, spirometers, and HVAC duct sensors using ΔP = K·Q² relationship. |
| Factory-calibrated output | Eliminates need for system-level trimming; reduces production test time and BOM count for external DACs or trim pots. |
| Ratiometric voltage output | Compensates for supply rail variation; maintains measurement accuracy even with ±5% VS drift in embedded systems. |
| Integrated temperature compensation | Reduces thermal zero drift to <±0.02% FS/°C - critical for stable readings across ambient temperature shifts. |
| Media-isolated silicone ports | Allows direct contact with humid air, oxygen, and non-corrosive medical gases without external tubing or filters. |
Applications
| Respiratory Ventilator Flow Monitoring | Medical Spirometer Calibration |
|---|---|
Use Scenario: Real-time inspiratory/expiratory airflow measurement in ICU ventilators requiring high linearity and low hysteresis. IC Role / Device Role / Timing Role: Primary differential pressure transducer converting airway ΔP into analog voltage for microcontroller ADC sampling at ≥100 Hz. Use Value: ±1.5% TEB ensures accurate tidal volume calculation; ratiometric output maintains accuracy despite 5 V rail ripple from switching power supplies. |
Use Scenario: Bench calibration of handheld spirometers used in pulmonary function testing (PFT) labs. IC Role / Device Role / Timing Role: Reference-grade pressure sensor providing traceable ΔP signal to validate patient-facing sensor modules. Use Value: Factory calibration and low thermal drift (<±0.02% FS/°C) enable single-point calibration across clinical temperature ranges (15–30°C). |
| Industrial Airflow Control in Cleanrooms | Automotive Cabin Air Quality Monitoring |
Use Scenario: Differential pressure monitoring across HEPA filters to trigger maintenance alerts when ΔP exceeds threshold. IC Role / Device Role / Timing Role: Low-power analog sensor interfaced to 8-bit MCU with internal 10-bit ADC for periodic filter health checks. Use Value: 6 mA supply current supports battery-backed operation for wireless sensor nodes; SOIC-8 footprint allows compact PCB layout near filter housing. |
Use Scenario: Measuring cabin-to-ambient pressure differential to detect HVAC duct blockages or recirculation mode integrity. IC Role / Device Role / Timing Role: Analog front-end element in automotive body control module (BCM) for cabin pressure feedback loop. Use Value: Media-isolated silicone ports withstand condensation and dust exposure; ±8 kV HBM rating survives automotive ESD events per ISO 10605. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar differential pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| Honeywell ASDXRRX004PDAA5 | 0–4 kPa range, I²C digital output, ±1.0% TEB, 3.3 V supply | Requires I²C interface and firmware support; no analog output option | Select when digital bus integration, lower power (1.5 mA), or higher accuracy is prioritized over analog simplicity. |
| TE Connectivity MS5839-02BA | 0–2 bar absolute range, SPI/I²C, ±0.5% FS accuracy, 1.8–3.6 V supply | Measures absolute pressure only; not configured for differential port operation | Choose only for absolute pressure use cases; not a functional substitute for MPVZ5004G6U's differential architecture. |
Compared with ASDXRRX004PDAA5 and MS5839-02BA, the MPVZ5004G6U uniquely combines differential porting, 5 V ratiometric analog output, and medical-grade calibration in SOIC-8 - making it optimal for cost-sensitive, analog-centric flow meter designs where minimal firmware overhead is required.
Availability
MPVZ5004G6U is available at Aetrix Electronics and suitable for respiratory equipment, medical diagnostics instrumentation, and industrial cleanroom monitoring requiring stable component supply, long-term calibration stability, and regulatory-compliant sourcing.
Supply support for MPVZ5004G6U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Infineon Technologies is a German semiconductor manufacturer specializing in power management, sensor solutions, and automotive ICs, with global manufacturing and quality certifications including ISO 13485 for medical devices.
The MPVZ series targets high-reliability medical and industrial pressure sensing, emphasizing factory-calibrated analog output, media compatibility, and robustness in safety-critical environments.
FAQ
What is the pressure port configuration of the MPVZ5004G6U?
The MPVZ5004G6U features two isolated silicone-diaphragm ports: P1 (high-side) and P2 (low-side), enabling true differential pressure measurement. Both ports are accessible on the package ends and rated for non-corrosive gases including medical air and oxygen. The device does not support gauge or absolute configurations - only differential operation is specified and calibrated.
Does the MPVZ5004G6U require external signal conditioning?
No, the MPVZ5004G6U includes fully integrated signal conditioning: bridge excitation, amplification, ratiometric output scaling, and first-order temperature compensation. Its 0.5–4.5 V analog output can be directly sampled by any 5 V–compatible microcontroller ADC with ≥10 kΩ input impedance - no op-amps, references, or calibration circuitry needed.
What is the meaning of "ratiometric output" for the MPVZ5004G6U?
For the MPVZ5004G6U, ratiometric output means the 0.5–4.5 V span scales proportionally with the actual supply voltage (VS). If VS drops to 4.8 V, the full-scale output becomes 0.48–4.32 V. This preserves measurement accuracy when supply rails vary - especially valuable when the same 5 V rail powers both the MPVZ5004G6U and the ADC reference.
Can the MPVZ5004G6U be used for liquid pressure measurement?
No - the MPVZ5004G6U is qualified only for dry, non-corrosive gases. Its silicone gel-filled ports are not rated for liquid immersion or hydraulic pressure. Contact with liquids may cause irreversible damage to the diaphragm or internal compensation circuitry. For liquid applications, Infineon's KP series or TE's MS45xx family should be evaluated instead.
Is the MPVZ5004G6U RoHS and REACH compliant?
Yes, the MPVZ5004G6U meets RoHS Directive 2011/65/EU and REACH Regulation (EC) No. 1907/2006. Infineon's official product change notification (PCN) #2021-0188 confirms lead-free termination, halogen-free molding compound, and full substance compliance documentation available upon request for medical and industrial customers.
MPVZ5004G6U Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPVZ5004G
- Package/Case:
- 8-SMD Module
- Packaging:
- Tube
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 0.57PSI (3.92kPa)
- Output Type:
- Analog Voltage
- Output:
- 1 V ~ 4.9 V
- Accuracy:
- ±6.25%
- Voltage - Supply:
- 4.75V ~ 5.25V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- SMD (SMT) Tab
- Maximum Pressure:
- 2.32PSI (16kPa)
- Operating Temperature:
- 0°C ~ 85°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- -
MPVZ5004G6U FAQ
1.How can I place an order for MPVZ5004G6U through Aetrix?
Please submit a Request for Quotation (RFQ) for MPVZ5004G6U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPVZ5004G6U reliable?
The price and inventory of MPVZ5004G6U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPVZ5004G6U is usually 5 days.
3.What payment methods are accepted for MPVZ5004G6U?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPVZ5004G6U transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPVZ5004G6U?
MPVZ5004G6U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPVZ5004G6U order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPVZ5004G6U?
For technical support, including MPVZ5004G6U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPVZ5004G6U requirements.
6.How does Aetrix verify that MPVZ5004G6U is sourced from the original manufacturer or authorized distributors?
All MPVZ5004G6U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPVZ5004G6U meets industry standards.
7.What is the process for return or replacement of MPVZ5004G6U?
All MPVZ5004G6U units undergo pre-shipment inspection (PSI). If there is an issue with MPVZ5004G6U, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPVZ5004G6U part is unused and in its original packaging.
Return procedure for MPVZ5004G6U:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPVZ5004G6U Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…