NXP Semiconductors MPVZ5010G6U
- Part No.:
- MPVZ5010G6U
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 8-SMD Module
- Datasheet:
-
MPVZ5010G6U.pdf
- Description:
- SENSOR 1.45PSIG 4.7V
- Quantity:
- Payment:

- Shipping:

Inventory:4,645
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPVZ5010G6U from Freescale Semiconductor is a fully integrated, on-chip signal-conditioned silicon pressure sensor with 0–10 kPa full-scale range, 0.2–4.7 V ratiometric analog output, and ±5.0% accuracy over 0° to 85°C. It features temperature compensation across –40° to +125°C, operates from 4.75–5.25 V supply, and delivers 5.0 mA typical supply current. Designed for industrial liquid level and respiratory equipment sensing, it uses a stainless steel cap port and PPS thermoplastic package.
For engineers reviewing the MPVZ5010G6U datasheet, MPVZ5010G6U pinout, MPVZ5010G6U application, or MPVZ5010G6U equivalent, this page provides verified technical context, pin-level design meaning, real-world use scenarios in appliance and medical systems, and validated alternative options for pressure transducer selection.
Technical Context
The MPVZ5010G6U integrates a piezoresistive sensing element, thin-film metallization, and bipolar signal conditioning circuitry-including two-stage gain amplification, offset correction, and temperature-compensated reference shift-onto a single monolithic silicon die. Its transfer function is VOUT = VS × (0.09 × P + 0.04), where P is pressure in kPa and VS is supply voltage.
It implements differential pressure sensing (P1 > P2) with a gel die coat isolating the die and wire bonds, while transmitting pressure via a stainless steel cap. The device requires external decoupling (1.0 µF + 0.01 µF + 470 pF) per Figure 3 to meet specified accuracy and response time of 1.0 ms (10%–90%).
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Full-Scale Range | 0–10 kPa (0–1019.78 mm H₂O); defines usable pressure span before output saturation |
| Output Voltage Range | 0.2–4.7 V at VS = 5.0 V; ratiometric scaling enables direct A/D interface with microcontrollers |
| Accuracy | ±5.0% VFSS over 0°–85°C; includes linearity, TcOffset, TcSpan, hysteresis, and variation from nominal |
| Supply Voltage | 4.75–5.25 Vdc; supports stable operation with standard 5 V rail and tolerates ±5% variation |
| Response Time | 1.0 ms (10%–90%); ensures fast dynamic pressure capture in washing machine fill cycles or breathing waveforms |
| Operating Temperature | –40° to +125°C; enables deployment in automotive under-hood or industrial ambient environments |
| Package Type | Case 482-01 SOP surface-mount package; 8-pin small outline with stainless steel cap port |
Pinout & Package
MPVZ5010G6U uses the Case 482-01 small-outline package: 10.54–10.79 mm × 10.54–10.79 mm × 5.38–5.84 mm body, with gull-wing leads, notch-marked Pin 1, and stainless steel cap on the P1 (pressure) side.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | No Connect | Internal connection; must remain unconnected to avoid interference with on-chip biasing |
| 2 | Supply Voltage (VS) | Primary power input; requires decoupling per Figure 3 to maintain ±5.0% accuracy |
| 3 | Ground (GND) | Analog ground reference for signal chain; must be low-impedance and separated from digital GND |
| 4 | Analog Output (VOUT) | Ratiometric 0.2–4.7 V signal proportional to pressure; connects directly to MCU A/D input |
| 5–8 | No Connect | Internal device connections; floating pins must not be tied to PCB traces or ground |
Key Features
| Feature | Design Value |
|---|---|
| On-chip signal conditioning | Eliminates need for external op-amps or ADC driver stages; reduces BOM count and layout area |
| Temperature compensation over –40° to +125°C | Enables reliable operation in wide ambient ranges without external thermal management |
| Durable PPS thermoplastic package | Resists moisture, solvents, and mechanical stress in appliance and healthcare enclosures |
| Stainless steel cap port (P1 side) | Provides media compatibility with water, air, and non-corrosive gases in liquid level applications |
| 0.5 kPa maximum pressure error band | Ensures consistent fill-level detection in washing machines within ±0.5 kPa tolerance |
Applications
| Washing Machine Water Level | Respiratory Equipment Monitoring |
|---|---|
Use Scenario: Detects water column height during drum fill cycle using differential pressure between sealed air chamber and atmosphere. IC Role / Device Role / Timing Role: Pressure transducer providing calibrated analog voltage proportional to hydrostatic head. Use Value: Enables precise fill-volume control without mechanical float switches; supports energy-efficient low-water wash modes. |
Use Scenario: Measures airway pressure waveform in portable ventilators and CPAP devices during inhalation/exhalation cycles. IC Role / Device Role / Timing Role: Differential pressure sensor capturing sub-kPa pressure variations with 1 ms response. Use Value: Delivers clinically relevant pressure resolution (0.5 kPa error) for breath-triggered therapy delivery. |
| Industrial Liquid Tank Level | Appliance Airflow Sensing |
Use Scenario: Monitors chemical or coolant level in sealed tanks via static head pressure measurement with vented reference (P2). IC Role / Device Role / Timing Role: Gauge-mode pressure sensor with stainless steel cap exposed to process media. Use Value: Supports long-term stability (±0.5% VFSS offset drift after 1000-hour pulsed test) in unattended industrial systems. |
Use Scenario: Detects fan or blower airflow obstruction in HVAC or range hood systems by measuring differential pressure across filter or duct. IC Role / Device Role / Timing Role: Low-range differential transducer with 10 kPa full scale and ratiometric output. Use Value: Enables real-time airflow diagnostics without requiring calibration against flow meters or anemometers. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar pressure transducer applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5010DP | Same 0–10 kPa range but dual-port differential configuration; no stainless steel cap; uses Case 867B package | Requires external porting for P1/P2; less robust for wet-side exposure in liquid level apps | Select when true differential pressure (not gauge) measurement is required and media isolation is handled externally |
| SSCDANT015PGAA3 | 0–15 psi (0–103.4 kPa) range; digital I²C output; higher accuracy (±0.25% FS); different supply (3.3 V) | Not ratiometric; requires MCU with I²C interface; unsuitable for direct A/D connection without level-shifting | Select when digital output, higher precision, or wider pressure range is needed-and system supports I²C protocol |
Compared with MPVZ5010G6U, MPX5010DP offers true differential sensing but lacks integrated media protection, while SSCDANT015PGAA3 provides digital precision at the cost of analog simplicity and 5 V compatibility-making MPVZ5010G6U optimal for cost-sensitive, microcontroller-based analog-sensing designs.
Availability
MPVZ5010G6U is available at Aetrix Electronics and suitable for washing machine water level control, respiratory equipment monitoring, and industrial liquid tank level sensing requiring stable component supply across extended production lifecycles.
Supply support for MPVZ5010G6U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Freescale Semiconductor (now part of NXP Semiconductors) is a global leader in embedded processing and sensor solutions, specializing in automotive, industrial, and consumer ICs with high reliability and system integration.
The MPVZ5010G6U belongs to Freescale's MPVZ series of integrated pressure sensors, designed specifically for cost-effective, high-volume analog pressure measurement in appliances, healthcare, and industrial controls where signal conditioning and temperature compensation must be embedded on-die.
FAQ
What is the pressure media compatibility of the MPVZ5010G6U?
The MPVZ5010G6U is qualified for use with dry air as the pressure medium. Its stainless steel cap and gel die coat provide limited compatibility with water and non-corrosive gases-but Freescale explicitly states that media other than dry air may affect long-term reliability. For MPVZ5010G6U deployments involving liquids or aggressive gases, factory consultation is required to confirm compatibility before design-in.
Does the MPVZ5010G6U require external calibration during system integration?
No, the MPVZ5010G6U is factory-calibrated and temperature-compensated across –40° to +125°C. Its output is ratiometric to supply voltage and follows the transfer function VOUT = VS × (0.09 × P + 0.04). While system-level gain/offset trimming may improve accuracy beyond ±5.0%, the MPVZ5010G6U delivers fully functional pressure data without field calibration.
What is the meaning of "N/C" on Pins 1 and 5–8 of the MPVZ5010G6U?
"N/C" stands for No Connect-these pins (1, 5, 6, 7, 8) are internal device connections with no external circuit function. They must remain unconnected on the PCB. Connecting them to ground, supply, or signal traces risks disrupting on-chip biasing, degrading accuracy, or causing device malfunction. Pin 1 is identified by the package notch and serves only as orientation marker.
Can the MPVZ5010G6U operate from a 3.3 V supply?
No-the MPVZ5010G6U is specified only for 4.75–5.25 Vdc supply. At 3.3 V, the internal signal conditioning circuitry fails to bias correctly, resulting in invalid or saturated output. The datasheet explicitly states "Device is ratiometric within this specified excitation range," and all operating characteristics (including 0.2–4.7 V output swing) assume VS = 5.0 V ± 0.25 V. Using 3.3 V violates absolute maximum ratings.
How does the MPVZ5010G6U handle temperature-induced errors outside 0°–85°C?
Within –40° to +125°C, the MPVZ5010G6U remains functional but its accuracy degrades: the ±5.0% VFSS specification applies only from 0° to 85°C. Outside that range, temperature error multipliers increase (×3 at –40°C and +125°C), widening the pressure error band. For MPVZ5010G6U use above 85°C, system-level compensation or derating is required to maintain acceptable measurement fidelity.
MPVZ5010G6U Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPVZ5010G
- Package/Case:
- 8-SMD Module
- Packaging:
- Tube
- Product Status:
- Obsolete
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 1.45PSI (10kPa)
- Output Type:
- Analog Voltage
- Output:
- 0.2 V ~ 4.7 V
- Accuracy:
- -
- Voltage - Supply:
- 4.75V ~ 5.25V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- SMD (SMT) Tab
- Maximum Pressure:
- 5.8PSI (40kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- -
MPVZ5010G6U FAQ
1.How can I place an order for MPVZ5010G6U through Aetrix?
Please submit a Request for Quotation (RFQ) for MPVZ5010G6U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPVZ5010G6U reliable?
The price and inventory of MPVZ5010G6U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPVZ5010G6U is usually 5 days.
3.What payment methods are accepted for MPVZ5010G6U?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPVZ5010G6U transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPVZ5010G6U?
MPVZ5010G6U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPVZ5010G6U order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPVZ5010G6U?
For technical support, including MPVZ5010G6U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPVZ5010G6U requirements.
6.How does Aetrix verify that MPVZ5010G6U is sourced from the original manufacturer or authorized distributors?
All MPVZ5010G6U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPVZ5010G6U meets industry standards.
7.What is the process for return or replacement of MPVZ5010G6U?
All MPVZ5010G6U units undergo pre-shipment inspection (PSI). If there is an issue with MPVZ5010G6U, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPVZ5010G6U part is unused and in its original packaging.
Return procedure for MPVZ5010G6U:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPVZ5010G6U Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…