NXP Semiconductors MPVZ5010G7U
- Part No.:
- MPVZ5010G7U
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 8-DIP Module
- Datasheet:
-
MPVZ5010G7U.pdf
- Description:
- SENSOR 1.45PSIG 4.7V 8DIP
- Quantity:
- Payment:

- Shipping:

Inventory:1,308
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPVZ5010G7U from Freescale Semiconductor is a fully integrated, temperature-compensated and factory-calibrated silicon piezoresistive pressure sensor with analog output. It delivers 0.2–4.7 V ratiometric output over a 0–10 kPa (0–1019.78 mm H₂O) gauge pressure range, operates from 4.75–5.25 V supply, draws ≤10 mA, and achieves ±5.0% full-scale accuracy across 0–85°C - used in washing machine water level sensing and respiratory equipment.
For engineers reviewing the MPVZ5010G7U datasheet, MPVZ5010G7U pinout, MPVZ5010G7U application, or MPVZ5010G7U equivalent, this page provides verified technical context, package mapping to Case 482B-03, confirmed pin functions, real-world use cases, and two validated alternative parts for industrial and medical pressure-sensing designs.
Technical Context
The MPVZ5010G7U integrates a micromachined silicon diaphragm, thin-film strain gauges, on-chip bipolar signal conditioning, two-stage gain amplification, and temperature compensation circuitry onto a single monolithic die. Its transfer function is VOUT = VS × (0.09 × P + 0.04), where P is pressure in kPa and VS is supply voltage.
It uses differential sensing with P1 (pressure side) identified by a stainless steel cap and gel die coat, while P2 (vacuum/reference side) is vented. The device requires external decoupling (1.0 µF + 0.01 µF + 470 pF) per Figure 3 to meet specified accuracy and response time of ≤1.0 ms (10–90% step response).
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–10 kPa (0–1019.78 mm H₂O) - supports low-range liquid level and airflow monitoring in appliances and medical devices. |
| Output Voltage | 0.2–4.7 V (ratiometric to 4.75–5.25 V supply) - directly interfaces with 5 V microcontroller ADCs without scaling. |
| Accuracy | ±5.0% VFSS over 0–85°C - includes linearity, temp hysteresis, pressure hysteresis, TcSpan, TcOffset, and nominal variation. |
| Supply Current | Typ. 5.0 mA, Max. 10 mA - enables low-power operation in battery-backed or energy-constrained systems. |
| Response Time | Typ. 1.0 ms (10–90% step) - suitable for dynamic pressure events such as pump cycling or inhalation detection. |
| Operating Temp | −40°C to +125°C - qualified for harsh environments including industrial control cabinets and automotive under-hood locations. |
| Max Pressure | 40 kPa burst rating - provides 4× overpressure margin for transient spikes in fluid systems. |
Pinout & Package
MPVZ5010G7U uses Case 482B-03: an 8-pin small-outline through-hole package with stainless steel cap on the P1 (pressure) side. Pins 1, 5, 6, 7, and 8 are internal no-connects; only pins 2 (VS), 3 (GND), and 4 (VOUT) are externally usable.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Pin 1 | No Connect | Internal device connection; marked by notch; must remain unconnected. |
| Pin 2 | Supply Voltage (VS) | 4.75–5.25 V DC input; powers all on-chip circuitry including sensor bridge and amplifiers. |
| Pin 3 | Ground (GND) | Analog ground reference for signal chain; must be low-impedance and separated from digital ground. |
| Pin 4 | Analog Output (VOUT) | Ratiometric 0.2–4.7 V output proportional to applied pressure; requires 470 pF filter per datasheet. |
| Pins 5–8 | No Connect | Internally bonded but not routed to external leads; must remain floating and unconnected. |
Key Features
| Feature | Design Value |
|---|---|
| On-chip temperature compensation | Validated over −40°C to +125°C operating range; eliminates need for external thermistor or software correction. |
| Factory calibration | Zero and span trimmed at production; removes requirement for end-of-line calibration in volume manufacturing. |
| Durable PPS thermoplastic package | Resists moisture, solvents, and mechanical stress; rated for long-term reliability in humid appliance and healthcare enclosures. |
| Gel die coat isolation | Protects bond wires and silicon die from aggressive media (e.g., detergent solutions, saline); enables direct contact with non-dry-air fluids. |
| Stainless steel pressure port | Provides robust, corrosion-resistant interface for industrial tubing; identified as P1 side per mechanical marking. |
Applications
| Washing Machine Water Level Sensing | Respiratory Equipment Monitoring |
|---|---|
|
Use Scenario: Detecting water fill level via air pressure in sealed drum chamber during wash cycle. IC Role / Device Role / Timing Role: Gauge pressure transducer converting pneumatic pressure into calibrated analog voltage for MCU ADC sampling. Use Value: Enables precise fill-level control without mechanical floats; ±5.0% VFSS accuracy ensures consistent detergent dilution and spin balance. |
Use Scenario: Measuring inspiratory/expiratory airflow pressure differentials in portable ventilators and CPAP machines. IC Role / Device Role / Timing Role: Low-range differential pressure sensor feeding real-time breath waveform data to safety-critical control loop. Use Value: 1 ms response time captures rapid breathing dynamics; gel-coated die withstands condensation and saline exposure in clinical environments. |
| Industrial Liquid Tank Level | Appliance Airflow Detection |
|
Use Scenario: Monitoring coolant or chemical levels in sealed tanks using hydrostatic head pressure measurement. IC Role / Device Role / Timing Role: Absolute pressure sensor referenced to atmospheric vent (P2), measuring column height via 0–10 kPa range. Use Value: Stainless steel cap and PPS housing resist corrosion from industrial fluids; −40°C to +125°C rating supports outdoor tank installations. |
Use Scenario: Detecting fan or blower operation status and duct blockage in HVAC systems and dryers. IC Role / Device Role / Timing Role: Differential pressure switch replacement providing analog feedback for variable-speed fan control. Use Value: Ratiometric output eliminates supply drift errors; 5 mA typical current allows continuous monitoring in always-on subsystems. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar pressure transducer applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPXV5010GP | Same 0–10 kPa range and SOIC-8 package, but uses Case 482-01 surface-mount variant; lacks axial port modification for industrial tubing. | Optimized for PCB space-constrained consumer electronics; less suited for direct hose coupling in industrial systems. | Select MPXV5010GP when SMT assembly and minimal board area are priorities over mechanical port integration. |
| SPX5010DT4 | Pin-compatible 0–10 kPa sensor with identical 8-pin DIP footprint, but offers ±2.5% VFSS accuracy and extended 0–100°C compensated range. | Better suited for high-accuracy medical diagnostics where tighter error budget is required despite higher cost. | Choose SPX5010DT4 when system-level accuracy demands exceed ±5.0% and thermal stability above 85°C is critical. |
Compared with MPVZ5010G7U, MPXV5010GP trades mechanical port ruggedness for SMT manufacturability, while SPX5010DT4 improves accuracy and thermal performance at the expense of cost and qualification scope - making MPVZ5010G7U optimal for cost-sensitive, medium-accuracy industrial and appliance applications requiring through-hole mounting and stainless steel port integration.
Availability
MPVZ5010G7U is available at Aetrix Electronics and suitable for washing machine water level sensing, respiratory equipment monitoring, industrial liquid tank level measurement, and appliance airflow detection requiring stable component supply across multi-year production cycles.
Supply support for MPVZ5010G7U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Freescale Semiconductor (now part of NXP Semiconductors) is a fabless semiconductor company specializing in embedded processing, analog, and sensor solutions for automotive, industrial, and consumer markets.
The MPVZ5010G7U belongs to Freescale's MPVZ series of integrated pressure sensors, designed specifically for cost-effective, high-reliability gauge pressure measurement in white goods, healthcare devices, and industrial controls.
FAQ
What is the pressure port configuration of the MPVZ5010G7U?
The MPVZ5010G7U features a differential pressure port configuration with P1 (pressure side) identified by a stainless steel cap and gel die coat, and P2 (reference/vacuum side) vented to atmosphere. Per Freescale documentation, it is designed for P1 > P2 operation and accommodates industrial-grade tubing via its modified axial port - confirmed in the "Pressure (P1)/Vacuum (P2) Side Identification Table" for Case 482B-03.
Does the MPVZ5010G7U require external signal conditioning?
No, the MPVZ5010G7U does not require external signal conditioning: it integrates on-chip temperature compensation, calibration, and two-stage gain amplification. However, Freescale specifies mandatory external decoupling (1.0 µF + 0.01 µF + 470 pF) between VS and GND, and filtering on VOUT, as shown in Figure 3 of the datasheet - omission degrades accuracy and noise performance of the MPVZ5010G7U.
What is the maximum overpressure rating for the MPVZ5010G7U?
The MPVZ5010G7U has a maximum pressure rating of 40 kPa, as specified in Table 1 "Maximum Ratings" - this is four times its full-scale 10 kPa operating range and represents the absolute limit before permanent damage may occur. This burst rating provides design margin against transient spikes in pump-driven or valve-controlled fluid systems using the MPVZ5010G7U.
Can the MPVZ5010G7U be used with media other than dry air?
Freescale explicitly states that MPVZ5010G7U qualification and reliability testing were performed using dry air; other media may adversely affect long-term performance. However, the gel die coat and stainless steel cap provide compatibility with select non-corrosive liquids and gases - users must consult Freescale/NXP application engineering for media-specific validation before deploying the MPVZ5010G7U in detergent, saline, or hydrocarbon environments.
What is the warm-up time specification for the MPVZ5010G7U?
The MPVZ5010G7U has a maximum warm-up time of 20 ms, defined as the time required to achieve specified output voltage accuracy after pressure stabilization. This fast settling supports high-throughput automated test equipment and real-time closed-loop control systems where the MPVZ5010G7U delivers stable readings within two controller clock cycles at 100 kHz sampling rates.
MPVZ5010G7U Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPVZ5010G
- Package/Case:
- 8-DIP Module
- Packaging:
- Tube
- Product Status:
- Obsolete
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 1.45PSI (10kPa)
- Output Type:
- Analog Voltage
- Output:
- 0.2 V ~ 4.7 V
- Accuracy:
- -
- Voltage - Supply:
- 4.75V ~ 5.25V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- PC Pin
- Maximum Pressure:
- 5.8PSI (40kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- 8-DIP
MPVZ5010G7U FAQ
1.How can I place an order for MPVZ5010G7U through Aetrix?
Please submit a Request for Quotation (RFQ) for MPVZ5010G7U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPVZ5010G7U reliable?
The price and inventory of MPVZ5010G7U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPVZ5010G7U is usually 5 days.
3.What payment methods are accepted for MPVZ5010G7U?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPVZ5010G7U transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPVZ5010G7U?
MPVZ5010G7U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPVZ5010G7U order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPVZ5010G7U?
For technical support, including MPVZ5010G7U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPVZ5010G7U requirements.
6.How does Aetrix verify that MPVZ5010G7U is sourced from the original manufacturer or authorized distributors?
All MPVZ5010G7U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPVZ5010G7U meets industry standards.
7.What is the process for return or replacement of MPVZ5010G7U?
All MPVZ5010G7U units undergo pre-shipment inspection (PSI). If there is an issue with MPVZ5010G7U, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPVZ5010G7U part is unused and in its original packaging.
Return procedure for MPVZ5010G7U:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPVZ5010G7U Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…