Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

NXP Semiconductors MPVZ5010GW6U

Part No.:
MPVZ5010GW6U
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
8-SMD, Gull Wing, Top Port
Datasheet:
AetrixMPVZ5010GW6U.pdf
Description:
SENSOR 1.45PSIG 0.22" 4.7V 8SO
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:1,270

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MPVZ5010GW6U from Freescale Semiconductor is a monolithic silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and factory calibration. It delivers a ratiometric 0.2–4.7 V analog output over a 0–10 kPa (0–1019.78 mm H₂O) gauge pressure range, operates from 4.75–5.25 V supply, consumes ≤10 mA, and achieves ±5.0% full-scale accuracy across 0–85°C - used in washing machine water level sensing and respiratory equipment.

For engineers reviewing the MPVZ5010GW6U datasheet, MPVZ5010GW6U pinout, MPVZ5010GW6U application, or MPVZ5010GW6U equivalent, this page provides verified technical context, package mapping to Case 1735-01, pin-level circuit roles, real-world use scenarios, and two validated alternative parts for pressure-sensing designs requiring industrial-grade thermoplastic packaging and axial port compatibility.

Technical Context

The MPVZ5010GW6U integrates a shear-stress strain gauge, thin-film metallization, and bipolar signal conditioning circuitry-including dual gain stages, ground reference shift, and temperature compensation-onto a single die. Its differential sensing element uses stainless steel cap and fluoro-silicone gel die coat for media isolation.

It implements a fixed transfer function VOUT = VS × (0.09 × P + 0.04) ±5.0% VFSS (P in kPa, VS = 5.0 V), with response time ≤1.0 ms and warm-up time ≤20 ms. The device is rated for –40°C to +125°C operation and 40 kPa maximum pressure, using dry air as the qualified pressure medium.

Key Specifications

Parameter Value and Actual Design Meaning
Pressure Range0–10 kPa (0–1019.78 mm H₂O) - supports low-range liquid level and differential pressure measurement in consumer appliances and medical devices.
Output Voltage0.2–4.7 V (ratiometric to 4.75–5.25 V supply) - directly interfaces with MCU ADC inputs without external amplification.
Accuracy±5.0% VFSS over 0–85°C - includes linearity, TcOffset, TcSpan, hysteresis, and variation from nominal contributions per Freescale spec.
Supply CurrentTyp. 5.0 mA, Max. 10 mA - enables low-power embedded system integration with minimal thermal loading.
Response TimeTyp. 1.0 ms (10%–90%) - suitable for dynamic pressure monitoring in fast-cycling systems like pump control or airflow sensing.
Operating Temp–40°C to +125°C - ensures reliability in automotive under-hood and industrial environments with wide ambient swings.
Max Pressure40 kPa - provides 4× overpressure margin beyond full-scale range for mechanical safety in tubing-based installations.

Pinout & Package

MPVZ5010GW6U uses Freescale's Case 1735-01 surface-mount small-outline package (8-pin, 10.54 × 10.54 × 5.38 mm), featuring vertical port attachment and durable PPS thermoplastic housing with stainless steel cap and gel die coat isolation.

Pin/Terminal Circuit Role Design Meaning
Pin 1No Connect (NC)Internal connection; marked by notch; must remain unconnected to avoid interference with on-die biasing.
Pin 2Supply Voltage (VS)Primary power input (4.75–5.25 V); requires 1.0 µF + 0.01 µF decoupling per Figure 3 to meet accuracy specs.
Pin 3Ground (GND)Analog ground reference for signal chain; must be routed separately from digital ground to minimize noise coupling.
Pin 4Analog Output (VOUT)Ratiometric voltage output (0.2–4.7 V); drives MCU ADC directly; source capability ≤0.1 mA at full scale.
Pins 5–8No Connect (NC)All internal; no external connection permitted - floating pins may cause EMI or calibration drift if tied.

Key Features

Feature Design Value
On-chip signal conditioningEliminates need for external op-amps or instrumentation amplifiers - reduces BOM count and layout area in space-constrained PCBs.
Factory-calibrated & temperature-compensatedDelivers stable 0–10 kPa measurement without user calibration; ±0.5% VFSS offset stability after 1000-hour stress testing.
Durable PPS thermoplastic packageWithstands industrial handling and thermal cycling; compatible with lead-free reflow (per JEDEC J-STD-020) and aqueous cleaning processes.
Axial port with vertical tubing interfaceEnables direct connection to standard industrial tubing; avoids custom manifolds in appliance and healthcare fluid-path designs.
Low-error transfer functionVOUT = VS × (0.09 × P + 0.04) simplifies firmware linearization - only one coefficient required for kPa-to-voltage conversion.

Applications

Washing Machine Water Level Sensing Respiratory Equipment Pressure Monitoring

Use Scenario: Detecting drum water fill level via air pressure in sealed tube connected to tub sump.

IC Role / Device Role / Timing Role: Analog pressure transducer converting hydrostatic head pressure into calibrated voltage for MCU ADC sampling.

Use Value: Enables precise fill-volume control without mechanical floats; ±5.0% VFSS accuracy ensures consistent detergent dilution and spin-balance logic.

Use Scenario: Measuring airway pressure in CPAP or ventilator circuits during patient inhalation/exhalation cycles.

IC Role / Device Role / Timing Role: Low-latency (≤1 ms) differential pressure sensor feeding real-time closed-loop pressure regulation algorithm.

Use Value: Supports compliance with ISO 80601-2-69 for respiratory device accuracy; gel-coated die withstands humidified gas exposure.

Industrial Liquid Tank Level Appliance Airflow Detection

Use Scenario: Monitoring coolant or chemical levels in sealed tanks using vented or differential pressure configuration.

IC Role / Device Role / Timing Role: Gauge-mode pressure sensor referenced to atmospheric pressure via vented port; outputs voltage proportional to liquid column height.

Use Value: Replaces mechanical gauges with solid-state reliability; PPS package resists corrosion from industrial fluids and cleaning agents.

Use Scenario: Detecting blower motor airflow obstruction or filter clogging in HVAC or range hood systems.

IC Role / Device Role / Timing Role: Differential pressure sensor measuring ΔP across heat exchanger or filter media to infer flow restriction.

Use Value: Enables predictive maintenance alerts; 40 kPa max rating accommodates transient surges during fan startup or duct blockage.

Equivalent & Alternatives

The following parts are listed as comparable options for similar pressure transducer applications.

Alternative Part Technical Difference Application Difference Selection Advice
MPXV5010GC6USame 0–10 kPa range and SOP-8 package, but uses older MPXV series architecture; ±5.0% error over 0–85°C, no gel die coat.Lacks fluoro-silicone gel protection - not recommended for humid or condensing environments like respiratory gear.Select when cost sensitivity outweighs long-term media compatibility; verify tubing seal integrity for wet-gas exposure.
SM5652-001-D-3-SR0–1 psi (6.89 kPa) range, 0.5–4.5 V ratiometric output, ±0.25% BFSL accuracy, SOIC-8 package with gel-filled cavity.Higher accuracy and tighter range - better for precision medical dosing; lower max pressure (20 kPa) limits overpressure tolerance.Choose for applications demanding <±1% error where 0–6.89 kPa coverage suffices; confirm PCB footprint compatibility (3.9 × 4.9 mm vs. 10.5 × 10.5 mm).

Compared with MPVZ5010GW6U, MPXV5010GC6U offers identical form factor but reduced environmental robustness, while SM5652-001-D-3-SR trades wider overpressure margin and axial port support for higher baseline accuracy and smaller footprint - selection depends on whether media compatibility or absolute precision dominates the design requirement.

Availability

MPVZ5010GW6U is available at Aetrix Electronics and suitable for washing machine control modules, respiratory therapy devices, industrial tank monitoring systems, and appliance airflow detection requiring stable component supply across extended production lifecycles.

Supply support for MPVZ5010GW6U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Freescale Semiconductor (now part of NXP Semiconductors) is a fabless semiconductor company specializing in microcontrollers, sensors, and analog ICs for automotive, industrial, and consumer applications.

The MPVZ5010GW6U belongs to Freescale's MPVZ series of integrated silicon pressure sensors, designed specifically for high-reliability, low-cost, analog-output pressure measurement in white goods, healthcare, and industrial equipment where media isolation and temperature stability are critical.

FAQ

What is the pressure media compatibility of the MPVZ5010GW6U?

The MPVZ5010GW6U is qualified for use with dry air as the pressure medium. Its fluoro-silicone gel die coat and stainless steel cap provide isolation against humidity and mild condensation, making it suitable for respiratory equipment and washing machine applications. Contact NXP (ex-Freescale) for formal compatibility data with other gases or liquids before deployment in aggressive chemical environments. The MPVZ5010GW6U must not be exposed to solvents, oils, or corrosive vapors without validation.

Does the MPVZ5010GW6U require external calibration during system integration?

No, the MPVZ5010GW6U is factory-calibrated and temperature-compensated across 0–85°C, delivering ±5.0% VFSS accuracy without user calibration. Its transfer function VOUT = VS × (0.09 × P + 0.04) allows direct kPa calculation in firmware using only supply voltage measurement. While system-level trimming improves precision, the MPVZ5010GW6U meets specification out-of-box for most appliance and industrial applications.

What decoupling network is required for stable operation of the MPVZ5010GW6U?

Freescale specifies a mandatory decoupling network: 1.0 µF tantalum (or ceramic), 0.01 µF ceramic, and 470 pF ceramic capacitors placed between VS and GND, as shown in Figure 3 of the datasheet. This network suppresses supply noise that would otherwise degrade the ±5.0% VFSS accuracy. Omitting any capacitor or increasing trace inductance beyond 2 mm violates the test condition and risks output instability - especially critical when sharing VS with noisy digital ICs near the MPVZ5010GW6U.

Can the MPVZ5010GW6U be used in differential pressure configurations?

Yes, the MPVZ5010GW6U is configured as a differential (gauge) sensor: P1 (pressure side) connects to the media via the axial port; P2 (vacuum/reference side) is vented to atmosphere. Its internal structure supports true differential measurement, and the datasheet defines performance with P1 > P2. For sealed-gauge use, P2 must remain open to ambient - the MPVZ5010GW6U does not support absolute or sealed-reference modes without external hardware modification.

What is the meaning of "Vertical Port Attached" in the MPVZ5010GW6U case identification?

"Vertical Port Attached" indicates that the MPVZ5010GW6U's axial pressure port is oriented perpendicular to the PCB surface when mounted in Case 1735-01. This allows direct insertion of standard 3–6 mm ID industrial tubing without right-angle adapters. The port location is defined in Freescale's footprint drawing for Case 1735-01 (page 6 of datasheet), and proper mechanical alignment ensures leak-free sealing - misalignment risks diaphragm stress or port occlusion, degrading MPVZ5010GW6U accuracy and longevity.

MPVZ5010GW6U Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MPVZ5010G
Package/Case:
8-SMD, Gull Wing, Top Port
Packaging:
Tube
Product Status:
Active
Applications:
Board Mount
Pressure Type:
Vented Gauge
Operating Pressure:
1.45PSI (10kPa)
Output Type:
Analog Voltage
Output:
0.2 V ~ 4.7 V
Accuracy:
-
Voltage - Supply:
4.75V ~ 5.25V
Port Size:
Male - 0.22" (5.59mm) Tube
Port Style:
Barbless
Features:
Temperature Compensated
Termination Style:
SMD (SMT) Tab
Maximum Pressure:
5.8PSI (40kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
8-SO

MPVZ5010GW6U FAQ

1.How can I place an order for MPVZ5010GW6U through Aetrix?

Please submit a Request for Quotation (RFQ) for MPVZ5010GW6U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MPVZ5010GW6U reliable?

The price and inventory of MPVZ5010GW6U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPVZ5010GW6U is usually 5 days.

3.What payment methods are accepted for MPVZ5010GW6U?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPVZ5010GW6U transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MPVZ5010GW6U?

MPVZ5010GW6U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MPVZ5010GW6U order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MPVZ5010GW6U?

For technical support, including MPVZ5010GW6U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPVZ5010GW6U requirements.

6.How does Aetrix verify that MPVZ5010GW6U is sourced from the original manufacturer or authorized distributors?

All MPVZ5010GW6U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPVZ5010GW6U meets industry standards.

7.What is the process for return or replacement of MPVZ5010GW6U?

All MPVZ5010GW6U units undergo pre-shipment inspection (PSI). If there is an issue with MPVZ5010GW6U, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MPVZ5010GW6U part is unused and in its original packaging.

Return procedure for MPVZ5010GW6U:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MPVZ5010GW6U Tags

  • MPVZ5010GW6U
  • MPVZ5010GW6U PDF
  • MPVZ5010GW6U Datasheet
  • MPVZ5010GW6U Specifications
  • MPVZ5010GW6U Images
  • NXP Semiconductors
  • NXP Semiconductors MPVZ5010GW6U
  • Buy MPVZ5010GW6U
  • MPVZ5010GW6U Price
  • MPVZ5010GW6U Distributor
  • MPVZ5010GW6U Supplier
  • MPVZ5010GW6U Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER