NXP Semiconductors MPX10GP
- Part No.:
- MPX10GP
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 4-SIP Module
- Datasheet:
-
MPX10GP.pdf
- Description:
- SENSOR 1.45PSIG 0.19" .035V
- Quantity:
- Payment:

- Shipping:

Inventory:3,239
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPX10GP from NXP Semiconductors is a silicon piezoresistive gauge pressure sensor with 10 kPa full-scale range, ratiometric voltage output (20–50 mV span at 3 V supply), ±1.0 %VFSS linearity, and −40 °C to +125 °C operating temperature. It features a durable epoxy unibody package (Case 344B-01) and is designed for integration into external temperature compensation and signal conditioning networks in pneumatic and medical diagnostics systems.
For engineers reviewing the MPX10GP datasheet, MPX10GP pinout, MPX10GP application, or MPX10GP equivalent, this page delivers verified technical context, exact pin definitions, real-world use scenarios, and validated alternative options - all grounded in NXP's Rev. 15 product data sheet dated 22 April 2021.
Technical Context
The MPX10GP implements a single-element silicon shear-stress strain gauge integrated directly onto the diaphragm, eliminating thermal expansion mismatch errors common in bonded-gauge sensors. Its ratiometric output scales linearly with supply voltage (3.0–6.0 VDC), enabling simplified analog interface design when paired with a stable reference.
It operates exclusively in gauge configuration (P1 > P2), with the pressure side identified by the port-attached surface per Case 344B-01 mechanical drawing. Output impedance (750–1250 Ω) and input impedance (400–550 Ω) are specified to guide external amplifier selection and minimize loading effects.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Full-Scale Pressure | 10 kPa - defines maximum measurable differential pressure before nonlinear response or damage risk. |
| Output Span (VS = 3 V) | 20–50 mV - determines minimum ADC resolution required for 1% accuracy (e.g., ≥12-bit for 10 kPa full scale). |
| Linearity Error | ±1.0 %VFSS - worst-case deviation from end-point straight-line fit over 0–10 kPa, critical for calibration budgeting. |
| Supply Voltage Range | 3.0–6.0 VDC - ratiometric operation allows shared reference with ADC, but self-heating increases above 6 V. |
| Operating Temperature | −40 °C to +125 °C - supports industrial and automotive under-hood environments without internal compensation. |
| Response Time | 1.0 ms (10–90%) - enables real-time monitoring of fast pneumatic transients such as valve actuation or leak pulses. |
| Offset Voltage | 0–35 mV at 0 kPa - requires trimming or software nulling in signal chain to achieve zero-pressure baseline accuracy. |
Pinout & Package
Epoxy unibody package (Case 344B-01), surface-mount, 4-pin, port-attached pressure side. Dimensions per SOT1753-1 outline.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | GND | Reference ground for both supply and output; must be low-impedance to minimize offset drift. |
| 2 | +VOUT | Positive bridge output terminal; connects to instrumentation amplifier non-inverting input. |
| 3 | VS | Excitation supply input; ratiometric scaling means output voltage ∝ VS × pressure. |
| 4 | –VOUT | Negative bridge output terminal; completes Wheatstone bridge measurement path. |
Key Features
| Feature | Design Value |
|---|---|
| Silicon shear-stress strain gauge | Eliminates thermal expansion mismatch between gauge and diaphragm, improving long-term stability vs. bonded gauges. |
| Ratiometric output | Enables direct interface with ratiometric ADCs or microcontroller references, removing need for independent voltage reference. |
| Gauge pressure configuration | Measures pressure relative to ambient atmosphere via port-attached side (P1), simplifying mounting in open-air systems. |
| Uncompensated architecture | Allows full customization of temperature compensation network (e.g., thermistor-based or digital lookup table) per system requirements. |
| Durable epoxy unibody | Provides mechanical robustness and environmental sealing for industrial pneumatics and medical devices exposed to vibration or humidity. |
Applications
| Air Movement Control | Leak Detection |
|---|---|
Use Scenario: Monitoring airflow in HVAC ducts or cleanroom ventilation systems to maintain laminar flow and pressure differentials. IC Role / Device Role / Timing Role: Gauge pressure sensor measuring static pressure drop across filters or dampers. Use Value: Enables closed-loop fan speed control using 10 kPa range matched to typical HVAC pressure differentials (0.5–8 kPa), with millisecond response supporting dynamic load changes. | Use Scenario: Detecting slow pressure decay in sealed pneumatic lines or medical gas delivery circuits over 1–60 second intervals. IC Role / Device Role / Timing Role: Low-drift gauge sensor capturing sub-kPa pressure changes during hold-and-monitor test cycles. Use Value: ±0.1 %VFSS pressure hysteresis and ±0.5 %VFSS offset stability over 1000-hour stress testing ensure repeatable pass/fail thresholds without recalibration. |
| Medical Diagnostics | Pneumatic Control Systems |
Use Scenario: Measuring respiratory airway pressure in portable spirometers or ventilator feedback loops during inhalation/exhalation cycles. IC Role / Device Role / Timing Role: Primary pressure transducer converting patient airway pressure into calibrated analog voltage for microcontroller sampling. Use Value: 1.0 ms response time captures rapid pressure transitions (<100 ms) in breathing waveforms, while −40 °C to +125 °C rating supports sterilization cycle tolerance. | Use Scenario: Closed-loop regulation of cylinder position or clamping force in automated assembly equipment using compressed air. IC Role / Device Role / Timing Role: Feedback element in PID-controlled pneumatic valve system measuring chamber pressure to adjust solenoid duty cycle. Use Value: Ratiometric output eliminates supply rail variation errors, and 35 mV max offset allows hardware zeroing with <1 kΩ trim potentiometer in production calibration. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar gauge pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX10D | Same 10 kPa range, identical pinout (GND/+VOUT/VS/–VOUT), but housed in Case 344-15 with stainless steel cap instead of port-attached epoxy unibody. | MPX10D uses stainless steel cap for P1 identification; better suited for high-vibration or washdown environments where port integrity is critical. | Select MPX10D if mechanical ruggedness or media isolation via metal cap is prioritized over port-based mounting flexibility. |
| MPXV10GC6U | Different package (SOT1854-1, Case 482A), 8-pin SOIC with 4 NC pins; same electrical specs but higher parasitic capacitance due to larger lead frame. | SOIC format enables through-hole or reflow-compatible PCB layout; NC pins simplify routing but increase board area vs. 4-pin SMT MPX10GP. | Choose MPXV10GC6U only when legacy SOIC footprint compatibility or manual prototyping convenience outweighs size and cost advantages of MPX10GP. |
Compared with MPX10D and MPXV10GC6U, the MPX10GP offers the smallest footprint and lowest unit cost among NXP's 10 kPa gauge sensors, with its port-attached unibody enabling direct hose or tube coupling - ideal for space-constrained medical and robotics designs requiring rapid pressure interface.
Availability
MPX10GP is available at Aetrix Electronics and suitable for air movement control, leak detection, and medical diagnostics requiring stable component supply across industrial and healthcare OEM programs.
Supply support for MPX10GP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT applications.
The MPX10 series belongs to NXP's legacy pressure sensor portfolio, engineered specifically for cost-sensitive, uncompensated gauge pressure measurement in pneumatic, environmental, and diagnostic systems where external signal conditioning is preferred.
FAQ
What is the pressure type and measurement range of the MPX10GP?
The MPX10GP is a gauge pressure sensor with a full-scale range of 0 to 10 kPa (0 to 1.45 PSI). It measures pressure relative to ambient atmospheric pressure via the port-attached side (P1), as defined in NXP's Case 344B-01 mechanical specification. The device is not rated for absolute or differential configurations - only gauge operation is supported for MPX10GP.
Does the MPX10GP include built-in temperature compensation?
No, the MPX10GP is an uncompensated sensor. Its output exhibits temperature-dependent full-scale span (−0.22 to −0.16 %VFSS/°C) and offset (±15 μV/°C) drift, requiring external compensation via resistive networks or digital correction. NXP provides guidance in Application Note AN840 for designing custom compensation circuits across −40 °C to +125 °C.
What is the correct pinout and connection method for MPX10GP?
The MPX10GP has four pins in order: Pin 1 = GND, Pin 2 = +VOUT, Pin 3 = VS, Pin 4 = –VOUT - as confirmed in Table 5 of the Rev. 15 datasheet. It forms a Wheatstone bridge; VS supplies excitation, and the differential output (+VOUT to –VOUT) must be measured with a high-input-impedance amplifier (Zin = 400–550 Ω, Zout = 750–1250 Ω).
Can MPX10GP be used with a 5 V supply, and how does supply voltage affect output?
Yes, MPX10GP operates from 3.0 V to 6.0 V DC. Its output is ratiometric: full-scale span (20–50 mV) and offset (0–35 mV) scale linearly with VS. At 5 V, expect ~1.67× higher output than at 3 V (e.g., ~33–83 mV span), but self-heating error increases above 6 V - so 5 V is within safe, optimal range for improved SNR without thermal penalty.
What are the key reliability specifications for MPX10GP in long-term deployment?
MPX10GP specifies ±0.5 %VFSS offset stability after 1000 hours of pulsed pressure-temperature cycling, ±0.1 %VFSS pressure hysteresis (0–10 kPa), and ±0.5 %VFSS temperature hysteresis (−40 °C to +125 °C). Burst pressure is rated at 100 kPa and overpressure at 75 kPa - exceeding its 10 kPa operating range by 7.5×, ensuring margin against transient spikes in pneumatic systems.
MPX10GP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPX10
- Package/Case:
- 4-SIP Module
- Packaging:
- Tray
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 1.45PSI (10kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 35 mV (3V)
- Accuracy:
- ±1%
- Voltage - Supply:
- 3V ~ 6V
- Port Size:
- Male - 0.19" (4.93mm) Tube
- Port Style:
- Barbed
- Features:
- -
- Termination Style:
- PC Pin
- Maximum Pressure:
- 10.88PSI (75kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- -
MPX10GP FAQ
1.How can I place an order for MPX10GP through Aetrix?
Please submit a Request for Quotation (RFQ) for MPX10GP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPX10GP reliable?
The price and inventory of MPX10GP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX10GP is usually 5 days.
3.What payment methods are accepted for MPX10GP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX10GP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPX10GP?
MPX10GP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPX10GP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPX10GP?
For technical support, including MPX10GP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX10GP requirements.
6.How does Aetrix verify that MPX10GP is sourced from the original manufacturer or authorized distributors?
All MPX10GP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX10GP meets industry standards.
7.What is the process for return or replacement of MPX10GP?
All MPX10GP units undergo pre-shipment inspection (PSI). If there is an issue with MPX10GP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPX10GP part is unused and in its original packaging.
Return procedure for MPX10GP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPX10GP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…