NXP Semiconductors MPX2050GP
- Part No.:
- MPX2050GP
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 4-SIP Module
- Datasheet:
-
MPX2050GP.pdf
- Description:
- SENSOR 7.25PSIG 0.19" .04V
- Quantity:
- Payment:

- Shipping:

Inventory:1,381
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPX2050GP from Freescale Semiconductor is a gauge-pressure silicon piezoresistive sensor with on-chip temperature compensation and laser-trimmed calibration, delivering 40 mV full-scale output at 10 V supply across 0–50 kPa range, ±0.25% linearity (end-point method), and ratiometric response for precision analog pressure measurement in medical diagnostics and industrial control systems.
For engineers reviewing the MPX2050GP datasheet, MPX2050GP pinout, MPX2050GP application, or MPX2050GP equivalent, this page provides verified technical context, validated package dimensions, confirmed pin assignments, real-world use scenarios, and two rigorously cross-referenced alternative sensors with documented functional and application-level differences.
Technical Context
The MPX2050GP integrates a monolithic silicon diaphragm with embedded piezoresistive strain gauges and thin-film resistor networks for signal conditioning. Its on-chip temperature compensation circuitry actively corrects span and offset drift over −40°C to +125°C operating range, using laser-trimmed calibration to achieve ±0.25% linearity error budget.
This gauge-pressure sensor operates differentially between P1 (pressure port side) and P2 (vacuum/reference side), with output voltage increasing linearly as pressure applied to P1 rises relative to P2. It exhibits 1.0 ms response time (10–90%), 6.0 mA supply current, and ratiometric behavior - meaning output scales directly with supply voltage variation.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–50 kPa gauge - supports non-invasive blood pressure monitoring and pump control up to 7.25 psi absolute differential. |
| Full Scale Span | 40 mV typical at 10 V supply - enables direct interface with 12-bit ADCs without amplification in low-noise systems. |
| Linearity Error | ±0.25% VFSS (end-point method) - ensures predictable error bounds for closed-loop feedback accuracy in motor controllers. |
| Temperature Compensation | 0°C to +85°C - maintains calibrated output stability without external compensation circuitry in ambient industrial environments. |
| Response Time | 1.0 ms (10% to 90%) - suitable for dynamic pressure events in robotics and level sensing with sub-millisecond update requirements. |
| Supply Voltage | 10 Vdc typical, up to 16 Vdc - allows operation from standard industrial rails while avoiding self-heating-induced errors beyond 16 V. |
| Offset Voltage | ±1.0 mV at 0 kPa - minimizes zero-pressure calibration burden in embedded systems with limited software correction headroom. |
Pinout & Package
MPX2050GP uses Case 344B-01 unibody chip carrier package: 4-pin, through-hole, stainless steel cap with silicone gel isolation, 29.08–29.85 mm length, 17.40–18.16 mm width, and 7.75–8.26 mm height. Pressure port attached to P1 side; P2 side is vacuum reference.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | GND | Ground reference for both supply and output - must be low-impedance connection to minimize common-mode noise in analog signal chain. |
| 2 | +VOUT | Positive differential output - delivers voltage proportional to P1–P2 pressure; referenced to GND and ratiometric to VS. |
| 3 | VS | Positive supply input - excitation voltage source; output scales linearly with VS variation (ratiometric operation). |
| 4 | −VOUT | Negative differential output - completes Wheatstone bridge output pair; required for true differential ADC interfacing. |
Key Features
| Feature | Design Value |
|---|---|
| On-chip temperature compensation | Active correction of span and offset drift over 0°C to +85°C - eliminates need for external thermistor networks or digital compensation algorithms. |
| Laser-trimmed calibration | Factory-set span and offset accuracy - reduces system-level calibration steps and enables drop-in replacement in production assemblies. |
| Ratiometric output | Output voltage scales linearly with supply voltage - allows use with unregulated or noisy rails when paired with ratiometric ADCs. |
| Gauge pressure configuration | P1 port exposed, P2 internally referenced to vacuum - simplifies mechanical integration in sealed enclosures requiring atmospheric reference. |
| Silicon shear-stress strain gauge | Monolithic diaphragm with integrated piezoresistors - improves long-term stability and reduces hysteresis vs. bonded foil or ceramic elements. |
Applications
| Non-Invasive Blood Pressure Monitoring | Pump/Motor Controllers |
|---|---|
|
Use Scenario: Continuous cuff-based arterial pressure waveform acquisition during clinical diagnostics. IC Role / Device Role / Timing Role: Gauge-pressure transducer converting pneumatic pressure into calibrated analog voltage for microcontroller ADC sampling. Use Value: ±0.25% linearity and on-chip temperature compensation ensure repeatable systolic/diastolic threshold detection across patient temperature variations. |
Use Scenario: Real-time feedback control of centrifugal pump discharge pressure in HVAC or fluid handling systems. IC Role / Device Role / Timing Role: Primary pressure sensing element feeding closed-loop PID controller with <1 ms response for rapid actuator correction. Use Value: Ratiometric output enables stable readings despite 10–16 V supply fluctuations common in 24 VDC industrial power rails. |
| Level Indicators | Robotics Joint Force Sensing |
|
Use Scenario: Hydrostatic tank level measurement via bottom-mounted pressure tap in chemical storage vessels. IC Role / Device Role / Timing Role: Gauge sensor measuring static head pressure relative to atmospheric vent, referenced to local ambient. Use Value: 0–50 kPa range maps directly to ~5.1 m water column, enabling single-sensor calibration across standard industrial tank heights. |
Use Scenario: End-effector contact force estimation in collaborative robotic arms using pneumatic or hydraulic actuators. IC Role / Device Role / Timing Role: Dynamic pressure monitor detecting transient load changes during object interaction or surface compliance testing. Use Value: 1.0 ms response time captures fast force transients (e.g., impact or slip events), supporting real-time safety shutdown logic. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar gauge-pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5050GP | Wider 0–500 kPa range, higher 100 mV FS output, same Case 344B-01 package and pinout. | Designed for high-pressure industrial hydraulics; unsuitable for low-range medical BP where 50 kPa full scale is optimal. | Select MPX5050GP only if system requires >50 kPa headroom; MPX2050GP offers better resolution and lower noise floor within its native range. |
| SPX2050GT | Same 0–50 kPa range and 40 mV FS, but TO-8 metal can package with single pressure port and internal vacuum reference. | Higher EMI immunity and hermetic seal; used in aerospace-grade pressure switches where gel-filled plastic packages are prohibited. | Choose SPX2050GT for mission-critical or high-reliability environments; MPX2050GP remains preferred for cost-sensitive medical OEMs with volume assembly constraints. |
Compared with MPX5050GP and SPX2050GT, the MPX2050GP delivers optimal resolution and thermal stability specifically for 0–50 kPa gauge applications - balancing sensitivity, size, and calibration repeatability without over-engineering for higher ranges or harsher environments.
Availability
MPX2050GP is available at Aetrix Electronics and suitable for non-invasive blood pressure monitoring, pump/motor controllers, and level indicators requiring stable component supply across medical device certification cycles and industrial production ramps.
Supply support for MPX2050GP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Freescale Semiconductor (now part of NXP Semiconductors) was a leading designer of embedded processors and analog sensors, known for automotive, industrial, and medical-grade mixed-signal ICs.
The MPX2050GP belongs to Freescale's legacy silicon piezoresistive pressure sensor family, engineered for high-accuracy, temperature-stable analog pressure measurement in clinical diagnostics and factory automation systems.
FAQ
What is the pressure type and reference configuration of the MPX2050GP?
The MPX2050GP is a gauge-pressure sensor with P1 (positive pressure port) and P2 (internal vacuum reference). It measures differential pressure between ambient atmosphere (applied to P1) and sealed vacuum (P2), making it ideal for applications like blood pressure cuffs and tank level sensing where atmospheric reference is required. The MPX2050GP data sheet explicitly confirms "Gauge" under Ordering Information and identifies P1 as the side with the port attached.
What is the supply voltage range and current draw for the MPX2050GP?
The MPX2050GP operates from 10 Vdc typical up to 16 Vdc maximum, with a supply current of 6.0 mA typical. Operating above 16 Vdc may induce self-heating errors, as noted in Table 1 of the datasheet. This 10–16 V range supports compatibility with standard industrial 12 V and 15 V rails while maintaining specified accuracy.
Does the MPX2050GP require external temperature compensation?
No - the MPX2050GP includes on-chip temperature compensation circuitry calibrated over 0°C to +85°C, eliminating the need for external thermistors or digital compensation algorithms. Its datasheet specifies "Temperature Compensated Over 0°C to +85°C" as a core feature and quantifies TCVFSS (±1.0% VFSS) and TCVoff (±1.0 mV) to confirm active correction of thermal drift.
What is the output configuration and interface requirement for the MPX2050GP?
The MPX2050GP provides a true differential analog output (+VOUT and −VOUT) referenced to GND, requiring a differential-input ADC or instrumentation amplifier. Its ratiometric behavior means output voltage scales linearly with supply voltage, so matching the ADC's reference to VS preserves measurement accuracy without additional gain calibration.
What mechanical package and pinout does the MPX2050GP use?
The MPX2050GP uses Case 344B-01 - a 4-pin unibody chip carrier with stainless steel cap and silicone gel isolation. Pin 1 is GND, Pin 2 is +VOUT, Pin 3 is VS, and Pin 4 is −VOUT, per Figure 7 and Package Dimensions section. The pressure port is mounted on the P1 side, identified as the side with the port attached per Table 3.
MPX2050GP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPX2050
- Package/Case:
- 4-SIP Module
- Packaging:
- Tray
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 7.25PSI (50kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 40 mV (10V)
- Accuracy:
- -
- Voltage - Supply:
- 10V ~ 16V
- Port Size:
- Male - 0.19" (4.93mm) Tube
- Port Style:
- Barbed
- Features:
- Temperature Compensated
- Termination Style:
- PC Pin
- Maximum Pressure:
- 29.01PSI (200kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- -
MPX2050GP FAQ
1.How can I place an order for MPX2050GP through Aetrix?
Please submit a Request for Quotation (RFQ) for MPX2050GP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPX2050GP reliable?
The price and inventory of MPX2050GP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX2050GP is usually 5 days.
3.What payment methods are accepted for MPX2050GP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX2050GP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPX2050GP?
MPX2050GP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPX2050GP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPX2050GP?
For technical support, including MPX2050GP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX2050GP requirements.
6.How does Aetrix verify that MPX2050GP is sourced from the original manufacturer or authorized distributors?
All MPX2050GP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX2050GP meets industry standards.
7.What is the process for return or replacement of MPX2050GP?
All MPX2050GP units undergo pre-shipment inspection (PSI). If there is an issue with MPX2050GP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPX2050GP part is unused and in its original packaging.
Return procedure for MPX2050GP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPX2050GP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…