NXP Semiconductors MPX2100AP
- Part No.:
- MPX2100AP
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 4-SIP Module
- Datasheet:
-
MPX2100AP.pdf
- Description:
- SENSOR 14.5PSIA 0.19" .04V
- Quantity:
- Payment:

- Shipping:

Inventory:2,359
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPX2100AP from Freescale Semiconductor is an absolute pressure sensor IC with on-chip temperature compensation and laser-trimmed calibration, delivering 40 mV full-scale output at 10 V supply across a 0–100 kPa range. It features ±0.25% linearity (end-point method), ratiometric output, and operates over –40°C to +125°C. Used in barometric sensing and medical diagnostics where stable, calibrated analog pressure signals are required.
For engineers reviewing the MPX2100AP datasheet, MPX2100AP pinout, MPX2100AP application, or MPX2100AP equivalent, this page provides verified technical context, package-validated pin functions, real-world use scenarios, and two confirmed alternative parts for pressure-sensing designs requiring absolute configuration, unibody packaging, and millivolt-level analog output.
Technical Context
The MPX2100AP integrates a monolithic silicon piezoresistive diaphragm with thin-film resistor networks for strain measurement and on-chip temperature compensation circuitry. Its output voltage is directly proportional to applied absolute pressure relative to internal vacuum reference, with offset and span trimmed via laser calibration.
It operates ratiometrically to supply voltage (10 V typical, up to 16 V max), exhibits 1.0 ms response time (10–90%), and maintains ±0.5% VFSS offset stability after 1000-hour pulsed pressure/temperature cycling. Input and output impedances are 1–2.5 kΩ and 1.4–3 kΩ respectively, enabling direct interface with instrumentation amplifiers or ADC front-ends.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–100 kPa absolute; enables barometric measurement (≈0–14.5 psi) without external reference. |
| Full Scale Span | 40 mV typical at 10 V supply; provides high signal-to-noise ratio for low-gain analog signal chains. |
| Linearity Error | ±0.25% VFSS (end-point method); supports precision pressure measurement without software linearization in many applications. |
| Temperature Range | –40°C to +125°C operating; suitable for under-hood automotive, industrial enclosures, and portable medical devices. |
| Supply Voltage | 10 V typical, 16 V max; ratiometric behavior ensures output scaling tracks supply variations, simplifying power rail design. |
| Response Time | 1.0 ms (10–90%); adequate for dynamic pressure monitoring in pump control and robotics. |
| Offset Voltage | ±2.0 mV at minimum rated pressure; low initial offset reduces need for null adjustment in production calibration. |
Pinout & Package
MPX2100AP uses Case 344B-01 - a unibody ceramic package with port-attached side identification (P1 side), stainless steel cap, and silicone gel isolation. Dimensions: 29.08–29.85 mm × 17.40–18.16 mm × 7.75–8.26 mm (L×W×H).
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | GND | Ground reference for both supply and output; must be low-impedance to minimize common-mode error. |
| 2 | +VOUT | Positive differential output terminal; delivers voltage proportional to absolute pressure above vacuum reference. |
| 3 | VS | Positive supply input (10 V typical); powers sensing element and compensation circuitry; ratiometric output scales with VS. |
| 4 | –VOUT | Negative differential output terminal; completes Wheatstone bridge output path; referenced to GND. |
Key Features
| Feature | Design Value |
|---|---|
| On-chip temperature compensation | Validated over 0°C to +85°C; eliminates need for external thermistor or digital correction in mid-range ambient applications. |
| Laser-trimmed span and offset | Reduces factory calibration effort; achieves ±0.25% linearity and ±2.0 mV offset without post-packaging trimming. |
| Ratiometric output | Output scales linearly with supply voltage; allows use of same regulator for sensor and downstream ADC, improving system accuracy. |
| Absolute pressure configuration | Internal vacuum reference enables true atmospheric or altitude-referenced measurements without external venting or plumbing. |
| Unibody ceramic package (Case 344B-01) | Robust mechanical construction with silicone gel protection; withstands humidity, vibration, and thermal cycling in harsh environments. |
Applications
| Barometric Pressure Monitoring | Medical Diagnostic Equipment |
|---|---|
|
Use Scenario: Measuring ambient atmospheric pressure for weather stations or altitude estimation in portable navigation devices. IC Role / Device Role / Timing Role: Absolute pressure transducer providing calibrated analog voltage output referenced to internal vacuum. Use Value: Delivers 40 mV full-scale output with ±0.25% linearity, enabling sub-100 Pa resolution using 16-bit ADCs without software linearization. |
Use Scenario: Non-invasive blood pressure or respiratory flow monitoring in clinical analyzers and ventilators. IC Role / Device Role / Timing Role: Primary pressure sensing element converting pneumatic pressure into ratiometric analog signal for analog front-end conditioning. Use Value: On-chip temperature compensation and ±0.5% VFSS offset stability over 1000-hour stress testing ensure long-term measurement repeatability in regulated medical systems. |
| Pump and Motor Control Systems | Industrial Level Indicators |
|
Use Scenario: Closed-loop pressure feedback in HVAC blower control or hydraulic pump regulation. IC Role / Device Role / Timing Role: Analog pressure feedback sensor interfaced to microcontroller ADC via instrumentation amplifier. Use Value: 1.0 ms response time and ratiometric output allow real-time pressure tracking and supply-independent control loop stability. |
Use Scenario: Liquid level detection in tanks using hydrostatic pressure measurement in chemical processing or water treatment plants. IC Role / Device Role / Timing Role: Absolute pressure transducer mounted at tank base, measuring column-induced pressure relative to atmospheric reference. Use Value: Case 344B-01 unibody package with silicone gel isolation resists corrosion and condensation, ensuring reliability in humid industrial settings. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX2100ASX | Same die, Case 344F-01 package with port-attached side identification; identical electrical specs and calibration. | Designed for surface-mount assembly with different mechanical mounting geometry; not drop-in compatible due to distinct footprint and port orientation. | Select MPX2100ASX only when board layout accommodates Case 344F-01's 27.43–28.45 mm × 18.80–19.30 mm outline and side-port configuration. |
| MPX5100AP | Successor generation with integrated signal conditioning; 0–100 kPa range, but outputs 0.2–4.7 V (not ratiometric mV) and requires 4.75–5.25 V supply. | Replaces discrete amplifier stages; incompatible with legacy MPX2100AP analog front-ends due to different output format and supply requirements. | Choose MPX5100AP for new designs needing amplified output and reduced external components; avoid for drop-in replacement of MPX2100AP. |
Compared with MPX2100ASX, MPX2100AP offers identical sensing performance but differs in mechanical mounting and port location-requiring PCB redesign. Compared with MPX5100AP, MPX2100AP retains legacy-compatible millivolt output and wide-supply operation but lacks onboard amplification, making it suitable for designs with existing precision gain stages.
Availability
MPX2100AP is available at Aetrix Electronics and suitable for barometric monitoring, medical diagnostics, and industrial level indication requiring stable component supply, long-lifecycle support, and traceable sourcing of legacy Freescale pressure sensors.
Supply support for MPX2100AP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Freescale Semiconductor (now part of NXP Semiconductors since 2015) was a leading designer of analog and mixed-signal ICs for automotive, industrial, and medical applications before its acquisition.
The MPX2100 series belongs to Freescale's legacy silicon piezoresistive pressure sensor product line, engineered for high-accuracy, temperature-stable analog pressure measurement in cost-sensitive, medium-volume industrial and diagnostic systems.
FAQ
What is the pressure type and reference configuration of the MPX2100AP?
The MPX2100AP is an absolute pressure sensor with an internal vacuum reference cavity. It measures pressure relative to perfect vacuum-not ambient air or a second port-making it suitable for barometric and altitude-sensing applications. This configuration is confirmed by Freescale's ordering table (MPX2100AP = Absolute, Case 344B) and the "P1 side" designation as the port-attached side with internal vacuum reference.
Does the MPX2100AP require external amplification to interface with a standard microcontroller ADC?
Yes, the MPX2100AP outputs a low-level ratiometric signal of approximately 40 mV full scale, which typically requires amplification (e.g., 50–100× gain) to match the input range of most 10–16 bit microcontroller ADCs. Its output impedance (1.4–3 kΩ) and differential nature also necessitate an instrumentation amplifier or matched resistor network for optimal common-mode rejection and noise immunity.
What is the maximum supply voltage rating for the MPX2100AP, and what happens if exceeded?
The MPX2100AP has a maximum supply voltage of 16 Vdc, per Freescale's Operating Characteristics table. Exceeding this limit may cause permanent damage or increased error due to self-heating, as explicitly noted in the datasheet. Operation at 10 Vdc is recommended for optimal linearity and temperature stability; higher voltages increase power dissipation without improving sensitivity.
Is the MPX2100AP RoHS compliant and lead-free?
The MPX2100AP/GP variant (as indicated in the ordering row) denotes green packaging per Freescale's nomenclature-meaning lead-free and RoHS-compliant. This is consistent with Freescale's 2008-era "GP" suffix convention (e.g., MPX2100AP/GP), aligned with EU RoHS Directive 2002/95/EC compliance requirements for industrial components shipped after July 1, 2006.
Can the MPX2100AP be used with wet media such as water or oil?
No-the MPX2100AP is qualified only for dry air as the pressure medium. Freescale explicitly states that "media other than dry air may have adverse effects on sensor performance and long term reliability." For liquid or corrosive gas applications, consult NXP (ex-Freescale) for media-compatible alternatives or custom qualification; standard MPX2100AP units lack protective coatings or seals for direct fluid contact.
MPX2100AP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPX2100
- Package/Case:
- 4-SIP Module
- Packaging:
- Tray
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Absolute
- Operating Pressure:
- 14.5PSI (100kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 40 mV (10V)
- Accuracy:
- -
- Voltage - Supply:
- 10V ~ 16V
- Port Size:
- Male - 0.19" (4.93mm) Tube
- Port Style:
- Barbed
- Features:
- Temperature Compensated
- Termination Style:
- PC Pin
- Maximum Pressure:
- 58.02PSI (400kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- -
MPX2100AP FAQ
1.How can I place an order for MPX2100AP through Aetrix?
Please submit a Request for Quotation (RFQ) for MPX2100AP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPX2100AP reliable?
The price and inventory of MPX2100AP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX2100AP is usually 5 days.
3.What payment methods are accepted for MPX2100AP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX2100AP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPX2100AP?
MPX2100AP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPX2100AP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPX2100AP?
For technical support, including MPX2100AP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX2100AP requirements.
6.How does Aetrix verify that MPX2100AP is sourced from the original manufacturer or authorized distributors?
All MPX2100AP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX2100AP meets industry standards.
7.What is the process for return or replacement of MPX2100AP?
All MPX2100AP units undergo pre-shipment inspection (PSI). If there is an issue with MPX2100AP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPX2100AP part is unused and in its original packaging.
Return procedure for MPX2100AP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPX2100AP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…