NXP Semiconductors MPX2100ASX
- Part No.:
- MPX2100ASX
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 4-SIP Module
- Datasheet:
-
MPX2100ASX.pdf
- Description:
- SENSOR 14.5PSIA 0.19" .04V
- Quantity:
- Payment:

- Shipping:

Inventory:3,512
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPX2100ASX from Freescale Semiconductor is an absolute-pressure silicon piezoresistive sensor with on-chip temperature compensation and laser-trimmed calibration, delivering 40 mV full-scale output at 10 V supply across 0–100 kPa range, used in barometric sensing and vacuum-referenced pressure monitoring.
For engineers reviewing the MPX2100ASX datasheet, MPX2100ASX pinout, MPX2100ASX application, or MPX2100ASX equivalent, this page provides verified technical context, package mapping to Case 344F-01, ratiometric output behavior, linearity (±1.0% VFSS), and validated alternatives for absolute-pressure measurement systems requiring stable offset and span over –40°C to +125°C.
Technical Context
The MPX2100ASX integrates a monolithic silicon diaphragm with embedded strain gauges and thin-film resistor networks for direct voltage output proportional to applied absolute pressure. Its internal circuitry includes laser-trimmed calibration for span and offset, plus passive temperature compensation over 0°C to +85°C.
It operates ratiometrically with supply voltage (10 V typical, up to 16 V max), exhibits 1.0 ms response time (10%–90%), and maintains ±0.5% VFSS offset stability after 1000-hour pulsed pressure/temperature cycling. The device uses dry air as specified pressure media; alternate media require factory validation.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–100 kPa absolute; enables barometric and sealed-vacuum chamber monitoring without external reference. |
| Full Scale Span | 38.5–41.5 mV at 10 V supply; provides high-resolution analog output scalable via ADC reference matching. |
| Linearity Error | ±1.0% VFSS (end-point method); defines worst-case deviation from ideal linear transfer function across full scale. |
| Offset Voltage | –2.0 to +2.0 mV at 0 kPa; sets baseline output for zero-pressure calibration in system firmware. |
| Supply Voltage | 10 V typical, 16 V maximum; ratiometric operation ensures output scaling tracks supply variations. |
| Response Time | 1.0 ms (10%–90%); supports dynamic pressure capture in pump control and robotics feedback loops. |
| Operating Temp | –40°C to +125°C; allows deployment in automotive under-hood and industrial ambient environments. |
Pinout & Package
MPX2100ASX uses the unibody Case 344F-01 package - a 4-pin, surface-mountable ceramic carrier with stainless steel cap and port-attached P1 side identification per Freescale documentation.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Pin 1 | GND | Ground reference for both supply and output; must be low-impedance to minimize offset drift. |
| Pin 2 | +VOUT | Positive differential output; delivers voltage proportional to absolute pressure relative to internal vacuum reference. |
| Pin 3 | VS | Supply input; powers sensing element and compensation circuitry; ratiometric scaling applies here. |
| Pin 4 | –VOUT | Negative differential output; completes Wheatstone bridge output path; referenced to GND in single-ended use. |
Key Features
| Feature | Design Value |
|---|---|
| On-chip temperature compensation | Validated over 0°C to +85°C; eliminates need for external thermistor-based correction in most applications. |
| Laser-trimmed calibration | Ensures <±0.5% VFSS offset stability and <±1.0% VFSS linearity without post-assembly trimming. |
| Ratiometric output | Output scales linearly with VS; simplifies interface to microcontrollers with shared ADC reference. |
| Absolute pressure configuration | Internal vacuum reference enables true atmospheric or sealed-system pressure measurement without external venting. |
| Dry-air media qualification | Specified performance guaranteed only with dry air; chemical compatibility requires factory consultation. |
Applications
| Barometric Pressure Monitoring | Pump/Motor Control Feedback |
|---|---|
Use Scenario: Measuring ambient atmospheric pressure for weather stations or altitude estimation in portable devices. IC Role / Device Role / Timing Role: Absolute-pressure transducer providing calibrated DC voltage output referenced to internal vacuum. Use Value: Delivers 40 mV full-scale span with ±1.0% VFSS linearity, enabling sub-1 kPa resolution using 12-bit ADCs without external amplification. |
Use Scenario: Closed-loop pressure regulation in HVAC blowers or industrial fluid pumps. IC Role / Device Role / Timing Role: Primary pressure feedback element in PID-controlled motor drive systems. Use Value: 1.0 ms response time and ratiometric output allow real-time pressure tracking synchronized with PWM motor control cycles. |
| Medical Diagnostic Equipment | Level Indication in Sealed Tanks |
Use Scenario: Non-invasive respiratory pressure monitoring in ventilators or spirometers. IC Role / Device Role / Timing Role: Absolute-pressure sensor measuring patient airway pressure against atmospheric reference. Use Value: –40°C to +125°C operating range supports sterilization cycles; offset stability <±0.5% VFSS ensures long-term calibration integrity. |
Use Scenario: Liquid level detection in pressurized storage tanks using hydrostatic head pressure. IC Role / Device Role / Timing Role: Absolute-pressure interface mounted at tank base to infer height from ΔP = ρgh. Use Value: 0–100 kPa range covers ~10 m water column; silicone gel isolation protects die from condensation and particulates. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute-pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5100AP | Higher supply voltage range (4.75–30 V), integrated signal conditioning, 5 V output; larger Case 402 package. | Requires no external amplifier; suited for 5 V microcontroller systems with space for larger footprint. | Select MPX5100AP when board space permits and 5 V rail simplifies signal chain integration. |
| SPX301-100 | 0–100 kPa absolute range, 0.5% FS accuracy, I²C digital output; SOIC-8 package with internal ADC and EEPROM calibration. | Eliminates analog front-end design; supports multi-sensor daisy-chaining and remote calibration updates. | Select SPX301-100 when digital interface, higher accuracy, or field-updatable calibration is required. |
Compared with MPX2100ASX, MPX5100AP offers wider supply flexibility and built-in amplification but requires more PCB area, while SPX301-100 replaces analog signal conditioning with digital intelligence at the cost of added firmware complexity and higher unit price.
Availability
MPX2100ASX is available at Aetrix Electronics and suitable for barometric monitoring, pump/motor control feedback, and medical diagnostic equipment requiring stable component supply across extended temperature ranges and long product lifecycles.
Supply support for MPX2100ASX includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Freescale Semiconductor (now part of NXP Semiconductors) designed high-performance analog sensors for automotive, industrial, and medical applications before its 2015 acquisition.
The MPX2100ASX belongs to Freescale's legacy MPX2100 series of silicon piezoresistive pressure sensors, engineered for absolute-pressure measurement in cost-sensitive, high-volume systems where analog output, temperature stability, and media compatibility are critical.
FAQ
What is the pressure type supported by MPX2100ASX?
The MPX2100ASX is an absolute-pressure sensor with an internal vacuum reference. It measures pressure relative to perfect vacuum, not ambient atmosphere or a second port. This makes MPX2100ASX suitable for barometric sensing, altimeters, and sealed-system monitoring where a fixed reference is required. Its P1 side (port-attached) must be exposed to the measured pressure, while the internal vacuum cavity serves as the reference.
What is the correct pinout configuration for MPX2100ASX?
The MPX2100ASX uses Style 1 pinout per Freescale documentation for Case 344F-01: Pin 1 = GND, Pin 2 = +VOUT, Pin 3 = VS (supply), Pin 4 = –VOUT. This matches the differential output configuration shown in Figure 1 and is confirmed in the PACKAGE DIMENSIONS section. Incorrect orientation-especially swapping VS and GND-can damage the device or produce invalid output.
Does MPX2100ASX require external temperature compensation?
No, MPX2100ASX does not require external temperature compensation. It features on-chip passive temperature compensation validated over 0°C to +85°C, with specified TCVoff ≤ ±1.0 mV and TCVFSS ≤ ±1.0% VFSS. While full-range operation extends to –40°C to +125°C, compensation performance is guaranteed only within the 0°C to +85°C band per datasheet Table 1.
Can MPX2100ASX be used with media other than dry air?
MPX2100ASX operating characteristics and reliability data are qualified only for dry air. Use with other gases or liquids may degrade long-term performance or cause failure due to chemical interaction with the silicone gel encapsulant or silicon diaphragm. Freescale explicitly advises contacting the factory for media compatibility validation before deploying MPX2100ASX with non-dry-air media.
What is the maximum overpressure rating for MPX2100ASX?
The MPX2100ASX has a maximum pressure rating of 400 kPa (Table 2, Maximum Ratings), which is four times its full-scale range of 0–100 kPa. Exceeding 400 kPa may cause permanent mechanical deformation of the silicon diaphragm or bond wire failure. This overpressure limit applies regardless of duration or temperature and is not recoverable.
MPX2100ASX Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPX2100
- Package/Case:
- 4-SIP Module
- Packaging:
- Tray
- Product Status:
- Obsolete
- Applications:
- Board Mount
- Pressure Type:
- Absolute
- Operating Pressure:
- 14.5PSI (100kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 40 mV (10V)
- Accuracy:
- -
- Voltage - Supply:
- 10V ~ 16V
- Port Size:
- Male - 0.19" (4.92mm) Tube
- Port Style:
- Barbed
- Features:
- Temperature Compensated
- Termination Style:
- PC Pin
- Maximum Pressure:
- 58.02PSI (400kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- -
MPX2100ASX FAQ
1.How can I place an order for MPX2100ASX through Aetrix?
Please submit a Request for Quotation (RFQ) for MPX2100ASX on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPX2100ASX reliable?
The price and inventory of MPX2100ASX are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX2100ASX is usually 5 days.
3.What payment methods are accepted for MPX2100ASX?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX2100ASX transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPX2100ASX?
MPX2100ASX orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPX2100ASX order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPX2100ASX?
For technical support, including MPX2100ASX datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX2100ASX requirements.
6.How does Aetrix verify that MPX2100ASX is sourced from the original manufacturer or authorized distributors?
All MPX2100ASX products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX2100ASX meets industry standards.
7.What is the process for return or replacement of MPX2100ASX?
All MPX2100ASX units undergo pre-shipment inspection (PSI). If there is an issue with MPX2100ASX, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPX2100ASX part is unused and in its original packaging.
Return procedure for MPX2100ASX:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPX2100ASX Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…
