Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

NXP Semiconductors MPX2102AP

Part No.:
MPX2102AP
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
4-SIP Module
Datasheet:
AetrixMPX2102AP.pdf
Description:
SENSOR 14.5PSIA 0.19" .04V
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:3,223

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MPX2102AP from Freescale Semiconductor is a temperature-compensated silicon piezoresistive absolute pressure sensor in Unibody Package (Case 344B), delivering 40 mV full-scale output at 10 V supply across 0–100 kPa range, with ±0.4%VFSS linearity and ±0.1%VFSS pressure hysteresis - used in medical diagnostics, barometers, and vacuum-sensing systems requiring stable analog pressure transduction.

For engineers reviewing the MPX2102AP datasheet, MPX2102AP pinout, MPX2102AP application, or MPX2102AP equivalent, this page provides verified technical context, calibrated performance parameters, package-specific terminal mapping, real-world use scenarios, and validated alternative options for pressure sensing design-in.

Technical Context

The MPX2102AP integrates a monolithic silicon diaphragm with on-chip strain gauge and thin-film resistor network, laser-trimmed for span/offset calibration and temperature compensation over 0°C to +85°C. Its ratiometric output scales linearly with applied absolute pressure relative to internal vacuum reference.

It operates with 10 VDC excitation (range 10–16 VDC), draws 6.0 mA supply current, and exhibits 1.0 ms response time (10%–90%), 20 ms warm-up time, and ±0.5%VFSS offset stability after 1000-hour pulsed pressure/temperature cycling test.

Key Specifications

ParameterValue and Actual Design Meaning
Pressure Range0–100 kPa absolute - defines full-scale operating envelope referenced to internal vacuum cavity.
Full Scale Span40 mV typical at 10 V supply - direct analog output proportional to pressure, enabling simple ADC interfacing without gain staging.
Linearity Error±0.4%VFSS (end-point method) - ensures ≤0.4 kPa deviation from ideal transfer curve across full scale at 25°C.
Offset Voltage−2.0 to +2.0 mV - output at zero pressure, critical for low-pressure accuracy and system zeroing calibration.
Temperature Compensation0°C to +85°C - on-chip circuitry minimizes span and offset drift, reducing need for external thermal correction.
Response Time1.0 ms (10%–90%) - supports dynamic pressure monitoring in fast-cycling applications like pump control or robotics.
Supply Voltage10–16 VDC - ratiometric operation maintains output proportionality even with supply variation within range.

Pinout & Package

MPX2102AP uses Unibody Package Case 344B: 4-pin, stainless-steel capped, ported housing with silicone-gel-isolated die; dimensions 29.08 × 17.40 × 8.26 mm (L × W × H), seating plane defined per ANSI Y14.5M-1982.

Pin/TerminalCircuit RoleDesign Meaning
1GroundReference node for output and supply return; must be low-impedance connection to minimize noise coupling.
2+ Output (VOUT+)High-side analog output terminal; delivers voltage proportional to absolute pressure (0–40 mV).
3+ Supply (VS)Excitation input; supplies regulated 10–16 VDC to internal Wheatstone bridge and compensation circuitry.
4− Output (VOUT−)Differential output complement; enables true differential readout to reject common-mode noise.

Key Features

FeatureDesign Value
On-chip temperature compensationReduces span and offset drift over 0°C to +85°C, eliminating need for external thermistor networks or software compensation algorithms.
Laser-trimmed calibrationEnsures factory-set accuracy for span and offset, enabling plug-and-play integration without user trimming.
Unibody absolute configurationInternal vacuum reference allows direct absolute pressure measurement without external reference port or plumbing.
Ratiometric outputMaintains proportional relationship between output voltage and supply voltage, improving system robustness against supply rail fluctuations.
Low-pressure hysteresis±0.1%VFSS hysteresis ensures repeatable readings during pressure cycling - critical for level detection and barometric trending.

Applications

Medical DiagnosticsBarometric Sensing

Use Scenario: Measuring respiratory airway pressure in portable ventilators and spirometers.

IC Role / Device Role / Timing Role: Absolute pressure transducer providing analog voltage output directly proportional to patient airway pressure relative to atmospheric vacuum reference.

Use Value: Enables accurate breath-phase detection and pressure-triggered ventilation cycles using only a single 10-bit ADC channel due to 40 mV full-scale range and low noise floor.

Use Scenario: Altitude estimation in UAVs and weather stations via ambient atmospheric pressure tracking.

IC Role / Device Role / Timing Role: High-stability absolute pressure sensor feeding continuous analog readings to microcontroller ADC for digital barometric compensation.

Use Value: Delivers ±0.4 kPa linearity and ±0.1%VFSS hysteresis, supporting <10 m altitude resolution without recalibration across temperature gradients.

Pump/Motor ControlLevel Detectors

Use Scenario: Closed-loop pressure feedback in HVAC blower systems and industrial fluid pumps.

IC Role / Device Role / Timing Role: Absolute pressure monitor detecting system backpressure to modulate motor speed and prevent overload.

Use Value: 1.0 ms response time and ratiometric output allow real-time PID control loop updates at >500 Hz sampling rates without signal conditioning.

Use Scenario: Non-invasive liquid level monitoring in tanks using hydrostatic head pressure measurement.

IC Role / Device Role / Timing Role: Absolute pressure transducer mounted at tank base, measuring static column pressure to infer fill height.

Use Value: On-chip temperature compensation ensures <±0.5% error over 0–85°C ambient, eliminating thermal drift-induced false level alarms.

Equivalent & Alternatives

The following parts are listed as comparable options for similar absolute pressure sensing applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
MPX2102ASame die, Case 344 (unported stainless cap); no P1 port; requires external pressure conduit.Used where environmental sealing is prioritized over direct port access; unsuitable for inline mounting.Select MPX2102A only when mechanical integration demands fully sealed housing and external tubing is acceptable.
MPXM2102ASMPAK package (Case 1320A), same 0–100 kPa absolute range, but higher input impedance (1.5 kΩ min) and different pinout (GND/VOUT−/VS/VOUT+).Designed for surface-mount assembly and space-constrained PCBs; lacks ported housing, requiring external pressure interface.Choose MPXM2102AS for automated SMT production and compact layouts, accepting trade-off of added external porting hardware.

Compared with MPX2102AP, MPX2102A offers identical sensing performance but requires external pressure routing, while MPXM2102AS enables smaller footprint and reflow compatibility at the cost of mechanical integration complexity and altered pin assignment.

Availability

MPX2102AP is available at Aetrix Electronics and suitable for medical diagnostics, barometric sensing, and pump/motor control applications requiring stable component supply, long-term calibration retention, and traceable sourcing for ISO 13485-aligned production.

Supply support for MPX2102AP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Freescale Semiconductor (now part of NXP Semiconductors) is a fabless semiconductor company specializing in embedded processing, analog sensors, and automotive-grade ICs.

The MPX2102 series belongs to Freescale's silicon piezoresistive pressure sensor product line, designed specifically for high-accuracy, temperature-stable absolute and differential pressure measurement in industrial, medical, and consumer instrumentation.

FAQ

What is the pressure type and reference configuration of the MPX2102AP?

The MPX2102AP is an absolute pressure sensor with an internal vacuum reference cavity. It measures pressure relative to perfect vacuum, not ambient atmosphere. This configuration is confirmed by its Case 344B packaging, ported on the P1 side, and documentation specifying "Absolute" in the ordering table. The MPX2102AP outputs a voltage that decreases under vacuum applied to the P1 port, consistent with absolute reference behavior. Its full-scale range is 0–100 kPa absolute.

What are the supply voltage requirements and current draw for MPX2102AP?

The MPX2102AP operates with a supply voltage of 10–16 VDC, with 10 VDC being the nominal excitation point for specified performance. At 10 VDC and 25°C, it draws 6.0 mA typical supply current. Operation above 16 VDC is not recommended due to self-heating effects that may increase error. The device is ratiometric, meaning its output voltage scales linearly with supply voltage, preserving measurement accuracy across the valid supply range.

Does MPX2102AP provide differential or single-ended output capability?

The MPX2102AP provides true differential analog output via pins 2 (+VOUT) and 4 (−VOUT), enabling noise-rejecting measurement with instrumentation amplifiers. It does not offer a single-ended output option - the ground-referenced output is not internally available. This differential architecture is integral to its design, as shown in Figure 1 of the datasheet, and supports high common-mode rejection in electrically noisy environments such as motor control or industrial equipment.

What is the temperature compensation range and accuracy impact for MPX2102AP?

The MPX2102AP features on-chip temperature compensation over 0°C to +85°C, covering its specified operating ambient range. Within this range, total error contributions include ±1.0%VFSS TcSpan and ±1.0 mV TcOffset, as documented in Table 1. These values represent worst-case deviations from 25°C baseline performance. The compensation is factory-laser-trimmed and does not require external components or software correction to meet datasheet accuracy specifications across the full compensated range.

Can MPX2102AP be used with media other than dry air?

No - the MPX2102AP's qualification testing and reliability data are based exclusively on dry air as the pressure medium. Freescale explicitly warns that exposure to other media (e.g., liquids, corrosive gases, or humid air) may degrade long-term performance or cause permanent damage. Silicone gel isolation protects the die but does not guarantee chemical compatibility. For non-dry-air applications, users must contact NXP (successor to Freescale) for media compatibility validation before deployment; the MPX2102AP datasheet does not authorize use with alternate media.

MPX2102AP Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MPX2102
Package/Case:
4-SIP Module
Packaging:
Tray
Product Status:
Active
Applications:
Board Mount
Pressure Type:
Absolute
Operating Pressure:
14.5PSI (100kPa)
Output Type:
Wheatstone Bridge
Output:
0 mV ~ 40 mV (10V)
Accuracy:
±1%
Voltage - Supply:
10V ~ 16V
Port Size:
Male - 0.19" (4.93mm) Tube
Port Style:
Barbed
Features:
Temperature Compensated
Termination Style:
PC Pin
Maximum Pressure:
58.02PSI (400kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Through Hole
Supplier Device Package:
-

MPX2102AP FAQ

1.How can I place an order for MPX2102AP through Aetrix?

Please submit a Request for Quotation (RFQ) for MPX2102AP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MPX2102AP reliable?

The price and inventory of MPX2102AP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX2102AP is usually 5 days.

3.What payment methods are accepted for MPX2102AP?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX2102AP transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MPX2102AP?

MPX2102AP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MPX2102AP order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MPX2102AP?

For technical support, including MPX2102AP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX2102AP requirements.

6.How does Aetrix verify that MPX2102AP is sourced from the original manufacturer or authorized distributors?

All MPX2102AP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX2102AP meets industry standards.

7.What is the process for return or replacement of MPX2102AP?

All MPX2102AP units undergo pre-shipment inspection (PSI). If there is an issue with MPX2102AP, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MPX2102AP part is unused and in its original packaging.

Return procedure for MPX2102AP:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MPX2102AP Tags

  • MPX2102AP
  • MPX2102AP PDF
  • MPX2102AP Datasheet
  • MPX2102AP Specifications
  • MPX2102AP Images
  • NXP Semiconductors
  • NXP Semiconductors MPX2102AP
  • Buy MPX2102AP
  • MPX2102AP Price
  • MPX2102AP Distributor
  • MPX2102AP Supplier
  • MPX2102AP Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER