NXP Semiconductors MPX2102AP
- Part No.:
- MPX2102AP
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 4-SIP Module
- Datasheet:
-
MPX2102AP.pdf
- Description:
- SENSOR 14.5PSIA 0.19" .04V
- Quantity:
- Payment:

- Shipping:

Inventory:3,223
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPX2102AP from Freescale Semiconductor is a temperature-compensated silicon piezoresistive absolute pressure sensor in Unibody Package (Case 344B), delivering 40 mV full-scale output at 10 V supply across 0–100 kPa range, with ±0.4%VFSS linearity and ±0.1%VFSS pressure hysteresis - used in medical diagnostics, barometers, and vacuum-sensing systems requiring stable analog pressure transduction.
For engineers reviewing the MPX2102AP datasheet, MPX2102AP pinout, MPX2102AP application, or MPX2102AP equivalent, this page provides verified technical context, calibrated performance parameters, package-specific terminal mapping, real-world use scenarios, and validated alternative options for pressure sensing design-in.
Technical Context
The MPX2102AP integrates a monolithic silicon diaphragm with on-chip strain gauge and thin-film resistor network, laser-trimmed for span/offset calibration and temperature compensation over 0°C to +85°C. Its ratiometric output scales linearly with applied absolute pressure relative to internal vacuum reference.
It operates with 10 VDC excitation (range 10–16 VDC), draws 6.0 mA supply current, and exhibits 1.0 ms response time (10%–90%), 20 ms warm-up time, and ±0.5%VFSS offset stability after 1000-hour pulsed pressure/temperature cycling test.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–100 kPa absolute - defines full-scale operating envelope referenced to internal vacuum cavity. |
| Full Scale Span | 40 mV typical at 10 V supply - direct analog output proportional to pressure, enabling simple ADC interfacing without gain staging. |
| Linearity Error | ±0.4%VFSS (end-point method) - ensures ≤0.4 kPa deviation from ideal transfer curve across full scale at 25°C. |
| Offset Voltage | −2.0 to +2.0 mV - output at zero pressure, critical for low-pressure accuracy and system zeroing calibration. |
| Temperature Compensation | 0°C to +85°C - on-chip circuitry minimizes span and offset drift, reducing need for external thermal correction. |
| Response Time | 1.0 ms (10%–90%) - supports dynamic pressure monitoring in fast-cycling applications like pump control or robotics. |
| Supply Voltage | 10–16 VDC - ratiometric operation maintains output proportionality even with supply variation within range. |
Pinout & Package
MPX2102AP uses Unibody Package Case 344B: 4-pin, stainless-steel capped, ported housing with silicone-gel-isolated die; dimensions 29.08 × 17.40 × 8.26 mm (L × W × H), seating plane defined per ANSI Y14.5M-1982.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | Ground | Reference node for output and supply return; must be low-impedance connection to minimize noise coupling. |
| 2 | + Output (VOUT+) | High-side analog output terminal; delivers voltage proportional to absolute pressure (0–40 mV). |
| 3 | + Supply (VS) | Excitation input; supplies regulated 10–16 VDC to internal Wheatstone bridge and compensation circuitry. |
| 4 | − Output (VOUT−) | Differential output complement; enables true differential readout to reject common-mode noise. |
Key Features
| Feature | Design Value |
|---|---|
| On-chip temperature compensation | Reduces span and offset drift over 0°C to +85°C, eliminating need for external thermistor networks or software compensation algorithms. |
| Laser-trimmed calibration | Ensures factory-set accuracy for span and offset, enabling plug-and-play integration without user trimming. |
| Unibody absolute configuration | Internal vacuum reference allows direct absolute pressure measurement without external reference port or plumbing. |
| Ratiometric output | Maintains proportional relationship between output voltage and supply voltage, improving system robustness against supply rail fluctuations. |
| Low-pressure hysteresis | ±0.1%VFSS hysteresis ensures repeatable readings during pressure cycling - critical for level detection and barometric trending. |
Applications
| Medical Diagnostics | Barometric Sensing |
|---|---|
Use Scenario: Measuring respiratory airway pressure in portable ventilators and spirometers. IC Role / Device Role / Timing Role: Absolute pressure transducer providing analog voltage output directly proportional to patient airway pressure relative to atmospheric vacuum reference. Use Value: Enables accurate breath-phase detection and pressure-triggered ventilation cycles using only a single 10-bit ADC channel due to 40 mV full-scale range and low noise floor. | Use Scenario: Altitude estimation in UAVs and weather stations via ambient atmospheric pressure tracking. IC Role / Device Role / Timing Role: High-stability absolute pressure sensor feeding continuous analog readings to microcontroller ADC for digital barometric compensation. Use Value: Delivers ±0.4 kPa linearity and ±0.1%VFSS hysteresis, supporting <10 m altitude resolution without recalibration across temperature gradients. |
| Pump/Motor Control | Level Detectors |
Use Scenario: Closed-loop pressure feedback in HVAC blower systems and industrial fluid pumps. IC Role / Device Role / Timing Role: Absolute pressure monitor detecting system backpressure to modulate motor speed and prevent overload. Use Value: 1.0 ms response time and ratiometric output allow real-time PID control loop updates at >500 Hz sampling rates without signal conditioning. | Use Scenario: Non-invasive liquid level monitoring in tanks using hydrostatic head pressure measurement. IC Role / Device Role / Timing Role: Absolute pressure transducer mounted at tank base, measuring static column pressure to infer fill height. Use Value: On-chip temperature compensation ensures <±0.5% error over 0–85°C ambient, eliminating thermal drift-induced false level alarms. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX2102A | Same die, Case 344 (unported stainless cap); no P1 port; requires external pressure conduit. | Used where environmental sealing is prioritized over direct port access; unsuitable for inline mounting. | Select MPX2102A only when mechanical integration demands fully sealed housing and external tubing is acceptable. |
| MPXM2102AS | MPAK package (Case 1320A), same 0–100 kPa absolute range, but higher input impedance (1.5 kΩ min) and different pinout (GND/VOUT−/VS/VOUT+). | Designed for surface-mount assembly and space-constrained PCBs; lacks ported housing, requiring external pressure interface. | Choose MPXM2102AS for automated SMT production and compact layouts, accepting trade-off of added external porting hardware. |
Compared with MPX2102AP, MPX2102A offers identical sensing performance but requires external pressure routing, while MPXM2102AS enables smaller footprint and reflow compatibility at the cost of mechanical integration complexity and altered pin assignment.
Availability
MPX2102AP is available at Aetrix Electronics and suitable for medical diagnostics, barometric sensing, and pump/motor control applications requiring stable component supply, long-term calibration retention, and traceable sourcing for ISO 13485-aligned production.
Supply support for MPX2102AP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Freescale Semiconductor (now part of NXP Semiconductors) is a fabless semiconductor company specializing in embedded processing, analog sensors, and automotive-grade ICs.
The MPX2102 series belongs to Freescale's silicon piezoresistive pressure sensor product line, designed specifically for high-accuracy, temperature-stable absolute and differential pressure measurement in industrial, medical, and consumer instrumentation.
FAQ
What is the pressure type and reference configuration of the MPX2102AP?
The MPX2102AP is an absolute pressure sensor with an internal vacuum reference cavity. It measures pressure relative to perfect vacuum, not ambient atmosphere. This configuration is confirmed by its Case 344B packaging, ported on the P1 side, and documentation specifying "Absolute" in the ordering table. The MPX2102AP outputs a voltage that decreases under vacuum applied to the P1 port, consistent with absolute reference behavior. Its full-scale range is 0–100 kPa absolute.
What are the supply voltage requirements and current draw for MPX2102AP?
The MPX2102AP operates with a supply voltage of 10–16 VDC, with 10 VDC being the nominal excitation point for specified performance. At 10 VDC and 25°C, it draws 6.0 mA typical supply current. Operation above 16 VDC is not recommended due to self-heating effects that may increase error. The device is ratiometric, meaning its output voltage scales linearly with supply voltage, preserving measurement accuracy across the valid supply range.
Does MPX2102AP provide differential or single-ended output capability?
The MPX2102AP provides true differential analog output via pins 2 (+VOUT) and 4 (−VOUT), enabling noise-rejecting measurement with instrumentation amplifiers. It does not offer a single-ended output option - the ground-referenced output is not internally available. This differential architecture is integral to its design, as shown in Figure 1 of the datasheet, and supports high common-mode rejection in electrically noisy environments such as motor control or industrial equipment.
What is the temperature compensation range and accuracy impact for MPX2102AP?
The MPX2102AP features on-chip temperature compensation over 0°C to +85°C, covering its specified operating ambient range. Within this range, total error contributions include ±1.0%VFSS TcSpan and ±1.0 mV TcOffset, as documented in Table 1. These values represent worst-case deviations from 25°C baseline performance. The compensation is factory-laser-trimmed and does not require external components or software correction to meet datasheet accuracy specifications across the full compensated range.
Can MPX2102AP be used with media other than dry air?
No - the MPX2102AP's qualification testing and reliability data are based exclusively on dry air as the pressure medium. Freescale explicitly warns that exposure to other media (e.g., liquids, corrosive gases, or humid air) may degrade long-term performance or cause permanent damage. Silicone gel isolation protects the die but does not guarantee chemical compatibility. For non-dry-air applications, users must contact NXP (successor to Freescale) for media compatibility validation before deployment; the MPX2102AP datasheet does not authorize use with alternate media.
MPX2102AP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPX2102
- Package/Case:
- 4-SIP Module
- Packaging:
- Tray
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Absolute
- Operating Pressure:
- 14.5PSI (100kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 40 mV (10V)
- Accuracy:
- ±1%
- Voltage - Supply:
- 10V ~ 16V
- Port Size:
- Male - 0.19" (4.93mm) Tube
- Port Style:
- Barbed
- Features:
- Temperature Compensated
- Termination Style:
- PC Pin
- Maximum Pressure:
- 58.02PSI (400kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- -
MPX2102AP FAQ
1.How can I place an order for MPX2102AP through Aetrix?
Please submit a Request for Quotation (RFQ) for MPX2102AP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPX2102AP reliable?
The price and inventory of MPX2102AP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX2102AP is usually 5 days.
3.What payment methods are accepted for MPX2102AP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX2102AP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPX2102AP?
MPX2102AP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPX2102AP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPX2102AP?
For technical support, including MPX2102AP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX2102AP requirements.
6.How does Aetrix verify that MPX2102AP is sourced from the original manufacturer or authorized distributors?
All MPX2102AP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX2102AP meets industry standards.
7.What is the process for return or replacement of MPX2102AP?
All MPX2102AP units undergo pre-shipment inspection (PSI). If there is an issue with MPX2102AP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPX2102AP part is unused and in its original packaging.
Return procedure for MPX2102AP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPX2102AP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…