NXP Semiconductors MPX2200GP
- Part No.:
- MPX2200GP
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 4-SIP Module
- Datasheet:
-
MPX2200GP.pdf
- Description:
- SENSOR 29.01PSIG 0.19" .04V
- Quantity:
- Payment:

- Shipping:

Inventory:116
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPX2200GP from Freescale Semiconductor is a gauge-pressure silicon piezoresistive sensor with on-chip temperature compensation, delivering 40 mV full-scale output at 10 V supply across 0–200 kPa range, ±0.25% linearity (end-point fit), and <1.0 ms response time. It operates from –40°C to +125°C and is used in medical diagnostics, level detection, and pressure switching where dry-air media compatibility and stable offset (<±1.0 mV) are critical.
For engineers reviewing the MPX2200GP datasheet, MPX2200GP pinout, MPX2200GP application, or MPX2200GP equivalent, this page provides verified package mapping (Case 344B-01), calibrated output behavior, pressure-side identification (port-attached side = P1), and direct alternatives for gauge-pressure sensing in industrial and medical systems.
Technical Context
The MPX2200GP integrates a monolithic silicon diaphragm with laser-trimmed thin-film resistor networks for span and offset calibration. Its ratiometric output scales linearly with supply voltage (10 V typical, up to 16 V max), and internal temperature compensation maintains accuracy over 0°C to +85°C operating range.
It uses a 4-pin unibody chip carrier (Case 344B-01) with dual ports: P1 (positive pressure side, identified by port attachment) and P2 (vacuum reference side). Output impedance (1400–3000 Ω) and input impedance (1300–2500 Ω) support direct interface with instrumentation amplifiers without buffering.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–200 kPa gauge; supports 29 psi full-scale measurement with dry air media only |
| Full Scale Span | 38.5–41.5 mV at VS = 10 VDC; enables high-resolution analog-to-digital conversion with 12-bit+ resolution |
| Linearity Error | ±0.25% VFSS (end-point fit); ensures predictable error budgeting in closed-loop control systems |
| Response Time | 1.0 ms (10% to 90%); suitable for dynamic pressure monitoring in pump/motor control |
| Operating Temp | –40°C to +125°C; validated for automotive under-hood and industrial embedded environments |
| Offset Voltage | –1.0 to +1.0 mV at min pressure; simplifies zero-point calibration in field-deployed instruments |
| Supply Voltage | 10 VDC typical, 16 VDC max; ratiometric operation allows shared reference with ADC for improved noise immunity |
Pinout & Package
MPX2200GP uses Case 344B-01: 4-pin unibody chip carrier with stainless steel cover, silicone gel isolation, and dual pressure ports. P1 (pressure side) is identified by the port-attached surface; P2 (vacuum reference) is the opposing side.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Pin 1 | Ground | Reference node for output and supply; must be low-impedance connection to minimize common-mode error |
| Pin 2 | + Output | High-side output terminal; delivers positive voltage proportional to P1–P2 differential pressure |
| Pin 3 | + Supply | Excitation input; device is ratiometric - output scales linearly with VS within 10–16 V range |
| Pin 4 | – Output | Low-side output terminal; completes Wheatstone bridge output path; referenced to ground |
Key Features
| Feature | Design Value |
|---|---|
| On-chip temperature compensation | Validated over 0°C to +85°C; eliminates need for external thermistor or digital correction in most applications |
| Laser-trimmed calibration | Factory-set span and offset; reduces system-level calibration effort and improves batch consistency |
| Dual-port gauge configuration | P1/P2 ports enable true gauge measurement against local ambient vacuum reference |
| Unibody package with silicone gel | Hermetic die protection while transmitting pressure signal; qualified for long-term reliability in humid environments |
| Ratiometric output | Output voltage scales with supply; enables use of same reference for ADC and sensor, improving noise rejection |
Applications
| Medical Diagnostics | Pump/Motor Control |
|---|---|
Use Scenario: Non-invasive blood pressure monitoring and respiratory flow sensing in portable diagnostic devices. IC Role / Device Role / Timing Role: Gauge-pressure transducer measuring differential air pressure across pneumatic pathways. Use Value: ±0.25% linearity and <1 ms response enable accurate waveform capture of systolic/diastolic peaks and breath cycles. |
Use Scenario: Closed-loop pressure feedback in HVAC blower systems and industrial hydraulic pumps. IC Role / Device Role / Timing Role: Primary pressure feedback element interfaced to microcontroller ADC via instrumentation amplifier. Use Value: Ratiometric output and wide temperature range (–40°C to +125°C) ensure stable control loop performance across environmental extremes. |
| Level Detectors | Barometers / Altimeters |
Use Scenario: Liquid level measurement in tanks using hydrostatic pressure of column height. IC Role / Device Role / Timing Role: Absolute-referenced gauge sensor converting fluid head pressure into calibrated voltage output. Use Value: 0–200 kPa range covers ~20 m water column; low hysteresis (±0.1% VFSS) ensures repeatable level readings after fill/empty cycles. |
Use Scenario: Altitude estimation in UAVs and portable weather stations via ambient air pressure tracking. IC Role / Device Role / Timing Role: Ambient-pressure gauge sensor referenced to sealed vacuum cavity (P2). Use Value: Temperature-compensated full-scale span (±1.0% VFSS drift) enables <10 m altitude resolution without active thermal management. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar gauge-pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5700GP | Higher full-scale range (0–700 kPa), 5 V supply, integrated signal conditioning; larger Case 867A package | Requires different PCB footprint and lower supply voltage; suited for higher-pressure industrial systems | Select when >200 kPa range or 5 V system integration is required |
| MPXV7007DP | Differential configuration (not gauge), 0–7 kPa range, I²C digital output, smaller SOIC-8 package | No P2 vacuum reference port; requires external vacuum source or absolute reference; digital interface replaces analog chain | Select when low-range differential measurement and digital bus integration are prioritized over analog simplicity |
Compared with MPX2200GP, MPX5700GP extends pressure range but increases board area and shifts supply requirements, while MPXV7007DP trades analog simplicity and gauge capability for digital output and ultra-low-range precision - neither is pin-compatible, and both require layout and firmware changes.
Availability
MPX2200GP is available at Aetrix Electronics and suitable for medical diagnostics, pump/motor control, and level detection requiring stable component supply, long-lifecycle support, and traceable sourcing for FDA-regulated or industrial safety-critical designs.
Supply support for MPX2200GP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Freescale Semiconductor (now part of NXP Semiconductors) was a leading designer of embedded processors and analog sensors, known for automotive, industrial, and medical-grade mixed-signal components.
The MPX2200GP belongs to Freescale's legacy MPX2200 series of silicon piezoresistive pressure sensors, engineered specifically for high-stability, temperature-compensated gauge-pressure measurement in safety- and reliability-sensitive applications.
FAQ
What is the pressure reference type of the MPX2200GP?
The MPX2200GP is a gauge-pressure sensor: it measures pressure relative to ambient atmospheric pressure, with P2 port sealed to an internal vacuum reference. This configuration enables direct reading of positive pressure applied to the P1 port without external venting, making it ideal for applications like liquid level sensing and medical airflow monitoring where absolute vacuum reference is impractical.
Does the MPX2200GP require external signal conditioning?
The MPX2200GP delivers a raw ratiometric analog output (typically 40 mV full-scale at 10 V supply) and does not include built-in amplification or ADC. Users must implement external signal conditioning - such as an instrumentation amplifier with gain ≥25 and low-offset design - to resolve sub-mV changes. Its 1400–3000 Ω output impedance and ±1.0 mV offset are optimized for this discrete analog front-end approach.
How is the pressure side (P1) identified on the MPX2200GP package?
Per Freescale documentation, the pressure side (P1) of the MPX2200GP is the side with the port attached - visible as a molded opening in the Case 344B-01 package. The opposing side (P2) is the vacuum reference and must remain unobstructed and sealed during assembly. Incorrect orientation results in inverted or null output, so mechanical mounting must align the port-attached surface with the measured pressure source.
What media compatibility limitations apply to the MPX2200GP?
The MPX2200GP is qualified only for dry air as the pressure medium. Exposure to moisture, oils, solvents, or corrosive gases may degrade the silicone gel encapsulant or corrode internal metallization, causing long-term drift or failure. Freescale explicitly states that alternate media require factory consultation - no derating or validation data is provided in the MPX2200GP datasheet for non-dry-air use.
Is the MPX2200GP RoHS-compliant and lead-free?
The MPX2200GP was manufactured prior to Freescale's full RoHS transition (pre-2006), and its datasheet Rev 13 (10/2008) does not declare RoHS compliance or lead-free status. No Pb-free variant (e.g., MPX2200GP* suffix) is documented. For new designs requiring RoHS conformance, engineers should verify current NXP-partnered sourcing or consider modern alternatives like the MP3V5050GV or NCP1855.
MPX2200GP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPX2200
- Package/Case:
- 4-SIP Module
- Packaging:
- Tray
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 29.01PSI (200kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 40 mV (10V)
- Accuracy:
- ±1%
- Voltage - Supply:
- 10V ~ 16V
- Port Size:
- Male - 0.19" (4.93mm) Tube
- Port Style:
- Barbed
- Features:
- Temperature Compensated
- Termination Style:
- PC Pin
- Maximum Pressure:
- 116.03PSI (800kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- -
MPX2200GP FAQ
1.How can I place an order for MPX2200GP through Aetrix?
Please submit a Request for Quotation (RFQ) for MPX2200GP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPX2200GP reliable?
The price and inventory of MPX2200GP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX2200GP is usually 5 days.
3.What payment methods are accepted for MPX2200GP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX2200GP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPX2200GP?
MPX2200GP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPX2200GP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPX2200GP?
For technical support, including MPX2200GP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX2200GP requirements.
6.How does Aetrix verify that MPX2200GP is sourced from the original manufacturer or authorized distributors?
All MPX2200GP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX2200GP meets industry standards.
7.What is the process for return or replacement of MPX2200GP?
All MPX2200GP units undergo pre-shipment inspection (PSI). If there is an issue with MPX2200GP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPX2200GP part is unused and in its original packaging.
Return procedure for MPX2200GP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPX2200GP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…