NXP Semiconductors MPX2202A
- Part No.:
- MPX2202A
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 4-SIP Module
- Datasheet:
-
MPX2202A.pdf
- Description:
- SENSOR 29.01PSIA .04V
- Quantity:
- Payment:

- Shipping:

Inventory:1,636
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPX2202A from Freescale Semiconductor is an absolute pressure sensor IC with monolithic silicon piezoresistive sensing element, on-chip temperature compensation (0°C to +85°C), ratiometric 40 mV full-scale output at 10 V supply, and 0–200 kPa (0–29 psi) measurement range - used in barometers, altimeters, and medical diagnostic equipment requiring stable analog pressure transduction.
For engineers reviewing the MPX2202A datasheet, MPX2202A pinout, MPX2202A application, or MPX2202A equivalent, this page delivers verified package mapping (Case 344-15), confirmed terminal roles (GND, +VOUT, VS, –VOUT), calibrated performance parameters (±1.0%VFSS linearity, ±0.5%VFSS offset stability), and real-world use context for embedded pressure-sensing systems.
Technical Context
The MPX2202A integrates a single silicon diaphragm with laser-trimmed strain gauges and thin-film resistor networks for precision span/offset calibration. Its internal circuitry provides ratiometric output scaling relative to supply voltage (VS = 10 Vdc typical), enabling direct ADC interfacing without external gain adjustment.
It features built-in vacuum reference for absolute pressure measurement, with output decreasing under vacuum applied to the P1 port. The device operates across –40°C to +125°C, though full temperature compensation is specified only over 0°C to +85°C per datasheet Table 1.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–200 kPa absolute - defines full-scale input range with built-in vacuum reference; supports barometric (≈100 kPa) and altimetric (≈30–100 kPa) applications. |
| Full Scale Span | 40 mV typical at VS = 10 V - enables high-resolution analog-to-digital conversion with minimal amplification (e.g., 12-bit ADC resolution ≈ 10 Pa). |
| Supply Voltage | 10 Vdc typical, 16 Vdc max - ratiometric operation ensures output scales linearly with supply; self-heating error increases above 10 V. |
| Linearity Error | ±1.0%VFSS (end-point method) - worst-case deviation from ideal linear transfer function across 0–200 kPa, critical for calibration-critical instrumentation. |
| Offset Voltage | –2.0 to +2.0 mV at min pressure - zero-pressure output tolerance; requires system-level offset nulling or calibration in precision applications. |
| Response Time | 1.0 ms (10% to 90%) - supports dynamic pressure monitoring up to ~350 Hz bandwidth without significant phase lag. |
| Operating Temp | –40°C to +125°C - wide ambient range suitable for industrial enclosures; compensated performance guaranteed only from 0°C to +85°C. |
Pinout & Package
MPX2202A uses the Unibody Package Case 344-15: stainless steel cap with silicone gel isolation, 4-pin lead frame, and P1 side identified by the stainless steel cap per Table 3.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | GND | Ground reference for output and supply return; must be low-impedance connection to minimize common-mode noise in ratiometric measurements. |
| 2 | +VOUT | Positive output terminal; delivers voltage proportional to applied absolute pressure (0–40 mV at 10 V supply). |
| 3 | VS | Positive supply input; excitation voltage source - output scales ratiometrically, so supply regulation directly impacts measurement accuracy. |
| 4 | –VOUT | Negative output terminal; completes differential output pair - required for noise-rejecting instrumentation amplifier interfaces. |
Key Features
| Feature | Design Value |
|---|---|
| On-chip temperature compensation | Stabilizes full-scale span and offset over 0°C to +85°C - eliminates need for external thermistor-based correction in portable barometers and altimeters. |
| Ratiometric output | Output voltage scales linearly with supply voltage - allows direct interface to microcontroller ADCs without separate voltage reference, reducing BOM count. |
| Laser-trimmed calibration | Factory-set span and offset via thin-film resistors - achieves ±1.0%VFSS linearity and ±0.5%VFSS offset stability without user calibration. |
| Stainless steel unibody package | Hermetic P1-side sealing with silicone gel protection - enables reliable operation in humid or mildly corrosive environments (e.g., medical airflow paths). |
| Differential output configuration | True 4-pin differential output (+VOUT/–VOUT) - improves common-mode noise rejection in electrically noisy motor-controller or pump-control applications. |
Applications
| Barometric Pressure Monitoring | Altimeter Systems |
|---|---|
Use Scenario: Measuring atmospheric pressure for weather station data logging or environmental monitoring. IC Role / Device Role / Timing Role: Absolute pressure transducer providing analog voltage output directly proportional to ambient air pressure. Use Value: 0–200 kPa range covers sea-level to 10,000 m altitude; ±1.0%VFSS linearity enables <±1 hPa absolute accuracy after one-point calibration. |
Use Scenario: Estimating elevation change in UAV navigation or wearable fitness trackers. IC Role / Device Role / Timing Role: Primary altitude-sensing element converting static air pressure into calibrated voltage for microcontroller ADC sampling. Use Value: 1.0 ms response time supports real-time ascent/descent tracking; ratiometric output simplifies integration with battery-powered MCU supply rails. |
| Medical Diagnostic Equipment | Pump/Motor Control Feedback |
Use Scenario: Non-invasive blood pressure estimation or respiratory flow analysis in clinical devices. IC Role / Device Role / Timing Role: Absolute pressure sensor referenced to sealed vacuum chamber, measuring patient airway or cuff pressure. Use Value: Stainless steel cap and silicone gel isolation ensure biocompatible media compatibility; ±0.5%VFSS offset stability maintains calibration over 1000-hour operational life. |
Use Scenario: Closed-loop pressure feedback in HVAC blower control or industrial fluid pump systems. IC Role / Device Role / Timing Role: Real-time pressure monitor detecting blockage, leak, or flow loss via absolute pressure deviation from setpoint. Use Value: 40 mV full-scale output provides sufficient signal swing for comparator-based switching or 12-bit ADC resolution down to ~10 Pa increments. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPXM2202A | Same 0–200 kPa absolute range and ratiometric output, but in MPAK package (Case 1320-02); higher thermal mass, slower warm-up (20 ms vs. MPX2202A's unspecified warm-up). | Preferred for surface-mount automated assembly; less robust mechanical mounting than unibody Case 344-15. | Select MPXM2202A when PCB space is constrained and reflow compatibility is required; MPX2202A remains optimal for ruggedized or through-hole prototyping. |
| MPXV2202GP | Gauge configuration (not absolute); lacks internal vacuum reference; measures pressure relative to ambient - incompatible for barometric/altimeter use without external vacuum reference. | Suitable only where ambient-referenced pressure is needed (e.g., tank level, differential airflow), not absolute pressure. | Do not substitute MPXV2202GP for MPX2202A in absolute pressure applications; verify pressure type (absolute vs. gauge) before selection. |
Compared with MPXM2202A, MPX2202A offers superior mechanical robustness and faster thermal stabilization in unibody packaging, while MPXV2202GP is functionally incompatible due to its gauge reference architecture - making MPX2202A the sole drop-in solution for vacuum-referenced absolute pressure measurement in legacy designs.
Availability
MPX2202A is available at Aetrix Electronics and suitable for barometric monitoring, altimeter systems, and medical diagnostic equipment requiring stable component supply, long-term calibration retention, and proven field reliability in industrial and healthcare environments.
Supply support for MPX2202A includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Freescale Semiconductor (now part of NXP Semiconductors) is a fabless semiconductor company specializing in embedded processing, sensors, and analog mixed-signal ICs for automotive, industrial, and medical markets.
The MPX2202 series was designed specifically for high-accuracy, temperature-stable analog pressure transduction in cost-sensitive embedded systems - emphasizing factory-calibrated performance, ratiometric simplicity, and mechanical durability in harsh environments.
FAQ
What is the pressure reference type of the MPX2202A?
The MPX2202A is an absolute pressure sensor with an internal vacuum reference cavity. As stated in the Freescale datasheet Rev 8, the device outputs a voltage that decreases when vacuum is drawn on the P1 port relative to ambient - confirming its absolute reference architecture. This distinguishes MPX2202A from differential or gauge variants like MPX2202DP or MPX2202GP, which require external reference ports.
Does the MPX2202A require external calibration for typical applications?
No, the MPX2202A does not require external calibration for most applications because it features factory laser trimming for span and offset, plus on-chip temperature compensation over 0°C to +85°C. Datasheet Table 1 confirms ±1.0%VFSS linearity and ±0.5%VFSS offset stability - performance levels achieved without user intervention. However, high-accuracy systems may apply one-point system-level calibration to correct residual offset.
What is the correct pin 1 identifier and orientation for MPX2202A (Case 344-15)?
Per Freescale Package Dimensions document CASE 344-15 Issue AA, pin 1 is marked by a chamfered corner on the lead frame and is located adjacent to the stainless steel cap - which identifies the P1 (pressure) side. The pinout is: Pin 1 = GND, Pin 2 = +VOUT, Pin 3 = VS, Pin 4 = –VOUT (Style 1). Orientation is confirmed by the "stainless steel cap" identifier in Table 3 of the MPX2202 datasheet.
Can the MPX2202A operate with supply voltages other than 10 Vdc?
Yes, the MPX2202A operates with supply voltages from unspecified minimum up to 16 Vdc, but its ratiometric output is specified at 10 Vdc typical. Datasheet Table 1 notes that operation above 10 Vdc may induce additional error due to self-heating. For best accuracy and thermal stability, 10 Vdc is recommended; lower voltages reduce output swing proportionally (e.g., 5 V supply yields ~20 mV full scale).
Is the MPX2202A compatible with wet or corrosive media?
No, the MPX2202A is qualified only for dry air as the pressure medium, as explicitly stated on page 5 of the datasheet. Exposure to liquids, oils, or chemically aggressive gases may degrade long-term reliability or cause irreversible damage to the silicone gel-isolated die. For non-air media, consult NXP (ex-Freescale) for qualified alternatives or custom qualification testing - MPX2202A itself is not rated for such use.
MPX2202A Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPX2202
- Package/Case:
- 4-SIP Module
- Packaging:
- Tray
- Product Status:
- Obsolete
- Applications:
- Board Mount
- Pressure Type:
- Absolute
- Operating Pressure:
- 29.01PSI (200kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 40 mV (10V)
- Accuracy:
- -
- Voltage - Supply:
- 10V ~ 16V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- PC Pin
- Maximum Pressure:
- 58.02PSI (400kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- -
MPX2202A FAQ
1.How can I place an order for MPX2202A through Aetrix?
Please submit a Request for Quotation (RFQ) for MPX2202A on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPX2202A reliable?
The price and inventory of MPX2202A are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX2202A is usually 5 days.
3.What payment methods are accepted for MPX2202A?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX2202A transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPX2202A?
MPX2202A orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPX2202A order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPX2202A?
For technical support, including MPX2202A datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX2202A requirements.
6.How does Aetrix verify that MPX2202A is sourced from the original manufacturer or authorized distributors?
All MPX2202A products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX2202A meets industry standards.
7.What is the process for return or replacement of MPX2202A?
All MPX2202A units undergo pre-shipment inspection (PSI). If there is an issue with MPX2202A, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPX2202A part is unused and in its original packaging.
Return procedure for MPX2202A:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPX2202A Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…