NXP Semiconductors MPX5010DP
- Part No.:
- MPX5010DP
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 6-SIP Module
- Datasheet:
-
MPX5010DP.pdf
- Description:
- SENSOR 1.45PSID 0.19" 4.7V
- Quantity:
- Payment:

- Shipping:

Inventory:1,821
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPX5010DP from NXP Semiconductors is a differential silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and factory calibration. It delivers a ratiometric analog output (0.2–4.925 V) over a 0–10 kPa pressure range at 5 V supply, with ±5.0% full-scale span accuracy across 0° to 85°C, and is packaged in a durable epoxy unibody SOT1756-1 (Case 867C-05) for industrial fluid sensing applications.
For engineers reviewing the MPX5010DP datasheet, MPX5010DP pinout, MPX5010DP application, or MPX5010DP equivalent, this page provides verified technical context, validated pin functions, real-world use scenarios in HVAC and medical devices, and two confirmed alternative parts with documented functional and packaging differences.
Technical Context
The MPX5010DP integrates a patented silicon shear-stress strain gauge with thin-film metallization and bipolar signal conditioning circuitry on a single monolithic die. Its architecture includes dual gain stages, ground-reference shift circuitry, and on-chip temperature compensation optimized for –40° to +125°C operation.
It operates as a ratiometric device: output voltage scales linearly with supply voltage (4.75–5.25 V), and its transfer function is defined as VOUT = VS × (0.09 × P + 0.04) ± 5.0% VFSS. Pins 4–6 are no-connects, confirming a 3-terminal active interface (VOUT, GND, VS) within a 6-pin unibody package.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–10 kPa differential (P1 > P2); enables precise low-pressure monitoring in respiratory systems and liquid level control. |
| Output Voltage Range | 0.2–4.925 V at VS = 5.0 V; ratiometric scaling ensures stable A/D conversion without external reference. |
| Accuracy | ±5.0% of full-scale span (VFSS) over 0° to 85°C; includes linearity, temperature hysteresis, and TcOffset contributions. |
| Supply Voltage | 4.75–5.25 V DC; supports standard microcontroller LDO rails and requires decoupling per Figure 11 (1.0 µF + 0.01 µF). |
| Response Time | 1.0 ms (10% to 90%); suitable for dynamic pressure events in washing machine water-level detection. |
| Operating Temperature | –40° to +125°C ambient; full temperature compensation applied on-die, not requiring external circuitry. |
| Package | SOT1756-1 (Case 867C-05); unibody epoxy/PPS surface-mount package with axial port for industrial tubing. |
Pinout & Package
SOT1756-1 is a 6-terminal unibody surface-mount package (17.78 mm × 29.48 mm × 10.67 mm) with axial pressure port, epoxy encapsulation, and thermoplastic (PPS) housing. Pin 1 is marked on the top-side silkscreen; P1 (pressure side) is identified by part marking per Table 7.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | VOUT | Analog output terminal; delivers conditioned, temperature-compensated voltage proportional to differential pressure. |
| 2 | GND | Analog ground reference; must be connected directly to system ground plane with low-impedance path. |
| 3 | VS | Supply voltage input; accepts 4.75–5.25 V DC and powers internal signal chain and compensation circuitry. |
| 4 | N.C. | No connect; internally unconnected - must remain floating, not tied to ground or supply. |
| 5 | N.C. | No connect; electrically isolated - PCB pad may be omitted or left unconnected. |
| 6 | N.C. | No connect; no internal bond wire or circuit node - no routing or soldering required. |
Key Features
| Feature | Design Value |
|---|---|
| On-chip temperature compensation | Compensates offset and span across –40° to +125°C using integrated thin-film resistors and bipolar circuitry - eliminates need for external calibration. |
| Differential pressure configuration | Two isolated ports (P1/P2) enable bidirectional pressure measurement; P1 side contains fluorosilicone gel for media isolation. |
| Ratiometric output | Output scales with supply voltage - maintains accuracy despite ±2.5% VS variation, simplifying power rail design in MCU-based systems. |
| Patented silicon shear-stress gauge | Monolithic micromachined element provides high stability and low hysteresis (<±0.5% VFSS after 1000-hour stress test). |
| Unibody SMT package | Epoxy/PPS construction withstands mechanical shock and thermal cycling; axial port accommodates 3/16″ industrial tubing per AN1950. |
Applications
| Hospital Respiratory Systems | HVAC Airflow Monitoring |
|---|---|
Use Scenario: Real-time differential pressure sensing across ventilator air filters and breathing circuits to detect occlusion or flow restriction. IC Role / Device Role / Timing Role: Primary pressure transducer providing analog feedback to closed-loop airflow control firmware. Use Value: ±5.0% VFSS accuracy and 1 ms response time enable rapid alarm triggering before patient safety thresholds are exceeded. |
Use Scenario: Measuring static pressure drop across HVAC duct dampers and heat exchangers to optimize fan speed and energy efficiency. IC Role / Device Role / Timing Role: Low-range differential sensor interfaced to 10-bit MCU ADC via ratiometric scaling. Use Value: On-chip temperature compensation ensures stable readings across –40° to +85°C ambient, eliminating field recalibration. |
| Washing Machine Water Level Control | Industrial Process Tank Monitoring |
Use Scenario: Detecting water column height in drum via air pressure in sealed tube connected to MPX5010DP's P1 port. IC Role / Device Role / Timing Role: Analog front-end sensor converting hydrostatic pressure into calibrated voltage for microcontroller interpretation. Use Value: 0–10 kPa range matches typical 0–1.02 m H₂O column; axial port and unibody package resist detergent exposure per AN1950. |
Use Scenario: Monitoring liquid level or filter clogging in chemical dosing tanks using differential pressure across a fixed orifice plate. IC Role / Device Role / Timing Role: Industrial-grade pressure interface with PPS housing and fluorosilicone gel isolation for non-corrosive media. Use Value: –40° to +125°C operating range supports deployment in outdoor or high-ambient enclosures without derating. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar differential pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5010GP | Same MPX5010 series, gauge configuration (single port referenced to atmosphere); identical SOT1756-1 package but Case 867B-04; 8.01 mm height vs. MPX5010DP's 10.67 mm. | Used where absolute pressure relative to ambient is required (e.g., barometric compensation), not differential across two sealed ports. | Select MPX5010GP only when atmospheric reference is acceptable and board height budget allows 2.66 mm reduction. |
| MPXV5010DP | Small-outline SOT1693-1 (12.06 mm × 12.06 mm × 7.62 mm); 8-pin package with different pinout (VS on pin 2, GND on pin 3, VOUT on pin 4); same 0–10 kPa range and ±5.0% accuracy. | Preferred for space-constrained designs; lacks axial port - requires external pressure interface; not rated for direct tubing connection. | Choose MPXV5010DP only when PCB area is critical and external pressure manifold can be implemented; not drop-in compatible. |
Compared with MPX5010GP and MPXV5010DP, the MPX5010DP uniquely combines differential porting, axial tubing compatibility, and unibody mechanical robustness - making it the only option among the three qualified for direct integration into medical respiratory and appliance liquid-level systems per AN1950.
Availability
MPX5010DP is available at Aetrix Electronics and suitable for hospital respiratory systems, HVAC airflow control, and washing machine water level measurement requiring stable component supply across extended production lifecycles.
Supply support for MPX5010DP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT applications.
The MPX5010 series was designed specifically for microcontroller-based pressure measurement systems requiring factory-calibrated, temperature-compensated analog output - targeting medical, appliance, and industrial process control markets.
FAQ
What is the maximum pressure rating for MPX5010DP?
The MPX5010DP has a maximum pressure rating of 40 kPa (P1 > P2), as specified in Table 5 of the Rev. 14 datasheet. This limiting value defines the absolute upper bound before permanent damage may occur; the recommended operating range remains 0–10 kPa. Exceeding 40 kPa voids reliability guarantees and risks diaphragm rupture or calibration drift. Always implement mechanical pressure limiting upstream when deploying MPX5010DP in variable-pressure environments.
Does MPX5010DP require external calibration?
No, MPX5010DP does not require external calibration. It ships fully calibrated from the factory with on-chip temperature compensation covering –40° to +125°C. The device's ±5.0% VFSS accuracy over 0° to 85°C is achieved using integrated thin-film resistors and bipolar signal conditioning - no trimming resistors, EEPROM, or software correction is needed. Users only need to apply proper decoupling (1.0 µF + 0.01 µF) per Figure 11 to maintain spec compliance for MPX5010DP.
Can MPX5010DP be used with a 3.3 V supply?
No, MPX5010DP is not specified for 3.3 V operation. Its recommended supply voltage is strictly 4.75–5.25 V DC (Table 6), and the ratiometric transfer function VOUT = VS × (0.09 × P + 0.04) assumes VS = 5.0 V. Operating below 4.75 V risks output saturation, reduced signal-to-noise ratio, and failure to meet ±5.0% VFSS accuracy. For 3.3 V systems, consider NXP's MP3V5004 or MPXV5004 series - not MPX5010DP.
What is the meaning of "N.C." on pins 4–6 of MPX5010DP?
"N.C." stands for "No Connect" - these pins (4, 5, and 6) have no internal electrical connection to the die or signal chain of MPX5010DP. They are physically present in the SOT1756-1 package for mechanical stability and handling but must remain unconnected in the PCB layout. Neither grounding nor pulling them to VS is permitted; doing so may compromise package integrity or introduce noise. This is explicitly confirmed in Figure 2 and Table 3 of the MPX5010DP datasheet.
Is MPX5010DP compatible with wet media such as water or cleaning fluids?
MPX5010DP is qualified for dry air only per Section 9 of the datasheet. Its fluorosilicone gel isolates the die but is not rated for direct contact with water, detergents, or solvents. In washing machine applications (Reference AN1950), it measures hydrostatic pressure indirectly via an air-filled tube - the sensor itself remains dry. For direct wet-media exposure, NXP recommends MPVZ5010 series variants with media-resistant gel; MPX5010DP must be deployed in dry-side configurations to ensure long-term reliability.
MPX5010DP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPX5010
- Package/Case:
- 6-SIP Module
- Packaging:
- Tray
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Differential
- Operating Pressure:
- 1.45PSI (10kPa)
- Output Type:
- Analog Voltage
- Output:
- 0.2 V ~ 4.7 V
- Accuracy:
- ±5%
- Voltage - Supply:
- 4.75V ~ 5.25V
- Port Size:
- Male - 0.19" (4.93mm) Tube, Dual
- Port Style:
- Barbed
- Features:
- Temperature Compensated
- Termination Style:
- PC Pin
- Maximum Pressure:
- 5.8PSI (40kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- -
MPX5010DP FAQ
1.How can I place an order for MPX5010DP through Aetrix?
Please submit a Request for Quotation (RFQ) for MPX5010DP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPX5010DP reliable?
The price and inventory of MPX5010DP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX5010DP is usually 5 days.
3.What payment methods are accepted for MPX5010DP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX5010DP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPX5010DP?
MPX5010DP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPX5010DP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPX5010DP?
For technical support, including MPX5010DP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX5010DP requirements.
6.How does Aetrix verify that MPX5010DP is sourced from the original manufacturer or authorized distributors?
All MPX5010DP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX5010DP meets industry standards.
7.What is the process for return or replacement of MPX5010DP?
All MPX5010DP units undergo pre-shipment inspection (PSI). If there is an issue with MPX5010DP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPX5010DP part is unused and in its original packaging.
Return procedure for MPX5010DP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPX5010DP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…