NXP Semiconductors MPX5010DP

Part No.:
MPX5010DP
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
6-SIP Module
Datasheet:
AetrixMPX5010DP.pdf
Description:
SENSOR 1.45PSID 0.19" 4.7V
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:1,821

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MPX5010DP from NXP Semiconductors is a differential silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and factory calibration. It delivers a ratiometric analog output (0.2–4.925 V) over a 0–10 kPa pressure range at 5 V supply, with ±5.0% full-scale span accuracy across 0° to 85°C, and is packaged in a durable epoxy unibody SOT1756-1 (Case 867C-05) for industrial fluid sensing applications.

For engineers reviewing the MPX5010DP datasheet, MPX5010DP pinout, MPX5010DP application, or MPX5010DP equivalent, this page provides verified technical context, validated pin functions, real-world use scenarios in HVAC and medical devices, and two confirmed alternative parts with documented functional and packaging differences.

Technical Context

The MPX5010DP integrates a patented silicon shear-stress strain gauge with thin-film metallization and bipolar signal conditioning circuitry on a single monolithic die. Its architecture includes dual gain stages, ground-reference shift circuitry, and on-chip temperature compensation optimized for –40° to +125°C operation.

It operates as a ratiometric device: output voltage scales linearly with supply voltage (4.75–5.25 V), and its transfer function is defined as VOUT = VS × (0.09 × P + 0.04) ± 5.0% VFSS. Pins 4–6 are no-connects, confirming a 3-terminal active interface (VOUT, GND, VS) within a 6-pin unibody package.

Key Specifications

Parameter Value and Actual Design Meaning
Pressure Range 0–10 kPa differential (P1 > P2); enables precise low-pressure monitoring in respiratory systems and liquid level control.
Output Voltage Range 0.2–4.925 V at VS = 5.0 V; ratiometric scaling ensures stable A/D conversion without external reference.
Accuracy ±5.0% of full-scale span (VFSS) over 0° to 85°C; includes linearity, temperature hysteresis, and TcOffset contributions.
Supply Voltage 4.75–5.25 V DC; supports standard microcontroller LDO rails and requires decoupling per Figure 11 (1.0 µF + 0.01 µF).
Response Time 1.0 ms (10% to 90%); suitable for dynamic pressure events in washing machine water-level detection.
Operating Temperature –40° to +125°C ambient; full temperature compensation applied on-die, not requiring external circuitry.
Package SOT1756-1 (Case 867C-05); unibody epoxy/PPS surface-mount package with axial port for industrial tubing.

Pinout & Package

SOT1756-1 is a 6-terminal unibody surface-mount package (17.78 mm × 29.48 mm × 10.67 mm) with axial pressure port, epoxy encapsulation, and thermoplastic (PPS) housing. Pin 1 is marked on the top-side silkscreen; P1 (pressure side) is identified by part marking per Table 7.

Pin/Terminal Circuit Role Design Meaning
1 VOUT Analog output terminal; delivers conditioned, temperature-compensated voltage proportional to differential pressure.
2 GND Analog ground reference; must be connected directly to system ground plane with low-impedance path.
3 VS Supply voltage input; accepts 4.75–5.25 V DC and powers internal signal chain and compensation circuitry.
4 N.C. No connect; internally unconnected - must remain floating, not tied to ground or supply.
5 N.C. No connect; electrically isolated - PCB pad may be omitted or left unconnected.
6 N.C. No connect; no internal bond wire or circuit node - no routing or soldering required.

Key Features

Feature Design Value
On-chip temperature compensation Compensates offset and span across –40° to +125°C using integrated thin-film resistors and bipolar circuitry - eliminates need for external calibration.
Differential pressure configuration Two isolated ports (P1/P2) enable bidirectional pressure measurement; P1 side contains fluorosilicone gel for media isolation.
Ratiometric output Output scales with supply voltage - maintains accuracy despite ±2.5% VS variation, simplifying power rail design in MCU-based systems.
Patented silicon shear-stress gauge Monolithic micromachined element provides high stability and low hysteresis (<±0.5% VFSS after 1000-hour stress test).
Unibody SMT package Epoxy/PPS construction withstands mechanical shock and thermal cycling; axial port accommodates 3/16″ industrial tubing per AN1950.

Applications

Hospital Respiratory Systems HVAC Airflow Monitoring

Use Scenario: Real-time differential pressure sensing across ventilator air filters and breathing circuits to detect occlusion or flow restriction.

IC Role / Device Role / Timing Role: Primary pressure transducer providing analog feedback to closed-loop airflow control firmware.

Use Value: ±5.0% VFSS accuracy and 1 ms response time enable rapid alarm triggering before patient safety thresholds are exceeded.

Use Scenario: Measuring static pressure drop across HVAC duct dampers and heat exchangers to optimize fan speed and energy efficiency.

IC Role / Device Role / Timing Role: Low-range differential sensor interfaced to 10-bit MCU ADC via ratiometric scaling.

Use Value: On-chip temperature compensation ensures stable readings across –40° to +85°C ambient, eliminating field recalibration.

Washing Machine Water Level Control Industrial Process Tank Monitoring

Use Scenario: Detecting water column height in drum via air pressure in sealed tube connected to MPX5010DP's P1 port.

IC Role / Device Role / Timing Role: Analog front-end sensor converting hydrostatic pressure into calibrated voltage for microcontroller interpretation.

Use Value: 0–10 kPa range matches typical 0–1.02 m H₂O column; axial port and unibody package resist detergent exposure per AN1950.

Use Scenario: Monitoring liquid level or filter clogging in chemical dosing tanks using differential pressure across a fixed orifice plate.

IC Role / Device Role / Timing Role: Industrial-grade pressure interface with PPS housing and fluorosilicone gel isolation for non-corrosive media.

Use Value: –40° to +125°C operating range supports deployment in outdoor or high-ambient enclosures without derating.

Equivalent & Alternatives

The following parts are listed as comparable options for similar differential pressure sensing applications.

Alternative Part Technical Difference Application Difference Selection Advice
MPX5010GP Same MPX5010 series, gauge configuration (single port referenced to atmosphere); identical SOT1756-1 package but Case 867B-04; 8.01 mm height vs. MPX5010DP's 10.67 mm. Used where absolute pressure relative to ambient is required (e.g., barometric compensation), not differential across two sealed ports. Select MPX5010GP only when atmospheric reference is acceptable and board height budget allows 2.66 mm reduction.
MPXV5010DP Small-outline SOT1693-1 (12.06 mm × 12.06 mm × 7.62 mm); 8-pin package with different pinout (VS on pin 2, GND on pin 3, VOUT on pin 4); same 0–10 kPa range and ±5.0% accuracy. Preferred for space-constrained designs; lacks axial port - requires external pressure interface; not rated for direct tubing connection. Choose MPXV5010DP only when PCB area is critical and external pressure manifold can be implemented; not drop-in compatible.

Compared with MPX5010GP and MPXV5010DP, the MPX5010DP uniquely combines differential porting, axial tubing compatibility, and unibody mechanical robustness - making it the only option among the three qualified for direct integration into medical respiratory and appliance liquid-level systems per AN1950.

Availability

MPX5010DP is available at Aetrix Electronics and suitable for hospital respiratory systems, HVAC airflow control, and washing machine water level measurement requiring stable component supply across extended production lifecycles.

Supply support for MPX5010DP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT applications.

The MPX5010 series was designed specifically for microcontroller-based pressure measurement systems requiring factory-calibrated, temperature-compensated analog output - targeting medical, appliance, and industrial process control markets.

FAQ

What is the maximum pressure rating for MPX5010DP?

The MPX5010DP has a maximum pressure rating of 40 kPa (P1 > P2), as specified in Table 5 of the Rev. 14 datasheet. This limiting value defines the absolute upper bound before permanent damage may occur; the recommended operating range remains 0–10 kPa. Exceeding 40 kPa voids reliability guarantees and risks diaphragm rupture or calibration drift. Always implement mechanical pressure limiting upstream when deploying MPX5010DP in variable-pressure environments.

Does MPX5010DP require external calibration?

No, MPX5010DP does not require external calibration. It ships fully calibrated from the factory with on-chip temperature compensation covering –40° to +125°C. The device's ±5.0% VFSS accuracy over 0° to 85°C is achieved using integrated thin-film resistors and bipolar signal conditioning - no trimming resistors, EEPROM, or software correction is needed. Users only need to apply proper decoupling (1.0 µF + 0.01 µF) per Figure 11 to maintain spec compliance for MPX5010DP.

Can MPX5010DP be used with a 3.3 V supply?

No, MPX5010DP is not specified for 3.3 V operation. Its recommended supply voltage is strictly 4.75–5.25 V DC (Table 6), and the ratiometric transfer function VOUT = VS × (0.09 × P + 0.04) assumes VS = 5.0 V. Operating below 4.75 V risks output saturation, reduced signal-to-noise ratio, and failure to meet ±5.0% VFSS accuracy. For 3.3 V systems, consider NXP's MP3V5004 or MPXV5004 series - not MPX5010DP.

What is the meaning of "N.C." on pins 4–6 of MPX5010DP?

"N.C." stands for "No Connect" - these pins (4, 5, and 6) have no internal electrical connection to the die or signal chain of MPX5010DP. They are physically present in the SOT1756-1 package for mechanical stability and handling but must remain unconnected in the PCB layout. Neither grounding nor pulling them to VS is permitted; doing so may compromise package integrity or introduce noise. This is explicitly confirmed in Figure 2 and Table 3 of the MPX5010DP datasheet.

Is MPX5010DP compatible with wet media such as water or cleaning fluids?

MPX5010DP is qualified for dry air only per Section 9 of the datasheet. Its fluorosilicone gel isolates the die but is not rated for direct contact with water, detergents, or solvents. In washing machine applications (Reference AN1950), it measures hydrostatic pressure indirectly via an air-filled tube - the sensor itself remains dry. For direct wet-media exposure, NXP recommends MPVZ5010 series variants with media-resistant gel; MPX5010DP must be deployed in dry-side configurations to ensure long-term reliability.

MPX5010DP Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MPX5010
Package/Case:
6-SIP Module
Packaging:
Tray
Product Status:
Active
Applications:
Board Mount
Pressure Type:
Differential
Operating Pressure:
1.45PSI (10kPa)
Output Type:
Analog Voltage
Output:
0.2 V ~ 4.7 V
Accuracy:
±5%
Voltage - Supply:
4.75V ~ 5.25V
Port Size:
Male - 0.19" (4.93mm) Tube, Dual
Port Style:
Barbed
Features:
Temperature Compensated
Termination Style:
PC Pin
Maximum Pressure:
5.8PSI (40kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Through Hole
Supplier Device Package:
-

MPX5010DP FAQ

1.How can I place an order for MPX5010DP through Aetrix?

Please submit a Request for Quotation (RFQ) for MPX5010DP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MPX5010DP reliable?

The price and inventory of MPX5010DP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX5010DP is usually 5 days.

3.What payment methods are accepted for MPX5010DP?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX5010DP transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MPX5010DP?

MPX5010DP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MPX5010DP order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MPX5010DP?

For technical support, including MPX5010DP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX5010DP requirements.

6.How does Aetrix verify that MPX5010DP is sourced from the original manufacturer or authorized distributors?

All MPX5010DP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX5010DP meets industry standards.

7.What is the process for return or replacement of MPX5010DP?

All MPX5010DP units undergo pre-shipment inspection (PSI). If there is an issue with MPX5010DP, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MPX5010DP part is unused and in its original packaging.

Return procedure for MPX5010DP:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MPX5010DP Tags

  • MPX5010DP
  • MPX5010DP PDF
  • MPX5010DP Datasheet
  • MPX5010DP Specifications
  • MPX5010DP Images
  • NXP Semiconductors
  • NXP Semiconductors MPX5010DP
  • Buy MPX5010DP
  • MPX5010DP Price
  • MPX5010DP Distributor
  • MPX5010DP Supplier
  • MPX5010DP Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER