NXP Semiconductors MPX5100AP

Part No.:
MPX5100AP
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
6-SIP Module
Datasheet:
AetrixMPX5100AP.pdf
Description:
SENSOR 16.68PSIA 0.19" 4.7V
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:4,752

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MPX5100AP from NXP Semiconductors is an absolute pressure sensor IC with monolithic silicon piezoresistive sensing element, on-chip temperature compensation, and ratiometric analog output. It delivers 4.7 V full-scale output at 100 kPa with ±2.5% accuracy over 0–85 °C, operates from 4.75–5.25 V supply, and draws 7 mA typical current. It is used in medical patient monitoring and industrial process control where dry-air-compatible, calibrated absolute pressure measurement is required.

For engineers reviewing the MPX5100AP datasheet, MPX5100AP pinout, MPX5100AP application, or MPX5100AP equivalent, this page provides verified technical context, validated pin functions, confirmed operating characteristics (including offset stability, response time, and sensitivity), and real-world application mapping for embedded microcontroller-based systems interfacing to A/D converters.

Technical Context

The MPX5100AP integrates a patented silicon shear-stress strain gauge with thin-film metallization and bipolar processing to generate a linear, temperature-compensated analog voltage output proportional to absolute pressure (0–100 kPa). Its transfer function is VOUT = VS × (P × 0.009 − 0.095), with built-in gain stages and ground reference shift circuitry.

It features on-chip temperature compensation across 0–85 °C, uses fluorosilicone gel isolation for die protection, and is qualified for operation with dry air as pressure media. The device requires no external calibration and exhibits ±0.5%VFSS offset stability after 1000-hour pulsed pressure/temperature cycling.

Key Specifications

ParameterValue and Actual Design Meaning
Pressure Range0 to 100 kPa absolute - defines full-scale input range for medical and industrial barometric/pressure-sensing applications.
Full-Scale Output4.700 V (typ) at VS = 5.0 V - enables direct interface to 5 V ADCs without signal conditioning.
Accuracy±2.5 %VFSS over 0–85 °C - includes linearity, temperature hysteresis, pressure hysteresis, TcSpan, and TcOffset contributions.
Sensitivity45 mV/kPa - determines resolution and signal-to-noise ratio in low-pressure detection systems.
Response Time1.0 ms (10% to 90%) - supports dynamic pressure monitoring in motor/pump control loops.
Supply Voltage4.75–5.25 VDC - ensures compatibility with standard 5 V microcontroller power rails and decoupling networks.
Operating Temp−40 to +125 °C - allows deployment in automotive under-hood and industrial ambient environments.

Pinout & Package

MPX5100AP uses the 6-lead unibody package (case 98ASB42796B), epoxy-encapsulated with stainless steel metal cover and integrated port for absolute pressure sensing. The package is surface-mountable with defined footprint per NXP documentation.

Pin/TerminalCircuit RoleDesign Meaning
1VOUTAnalog output voltage proportional to absolute pressure - connects directly to microcontroller ADC input with optional RC filtering.
2GNDAnalog ground reference - must be tied to system AGND with low-impedance path to minimize noise coupling.
3VSPositive supply input - requires 4.75–5.25 V with 1.0 μF bulk and 0.01 μF ceramic decoupling per datasheet Figure 7.
4–6DNCInternal device connections - must remain unconnected; no external routing or grounding permitted.

Key Features

FeatureDesign Value
On-chip temperature compensationEliminates need for external thermistor networks or software correction algorithms across 0–85 °C.
Ratiometric outputOutput scales linearly with supply voltage - maintains accuracy even with ±0.25 V variation in 5 V rail.
Durable epoxy unibody constructionProvides mechanical robustness and long-term reliability in vibration-prone industrial equipment enclosures.
Fluorosilicone gel isolationProtects die and wire bonds from moisture and particulates while transmitting pressure accurately through the diaphragm.
Patented silicon shear-stress strain gaugeDelivers superior linearity and reduced hysteresis vs. conventional piezoresistive elements in absolute configuration.

Applications

Patient MonitoringProcess Control

Use Scenario: Continuous non-invasive blood pressure and respiratory pressure tracking in ICU ventilators and portable monitors.

IC Role / Device Role / Timing Role: Absolute pressure transducer converting airway or cuff pressure into calibrated analog voltage for microcontroller ADC sampling.

Use Value: Enables FDA-compliant pressure measurement with ±2.5%VFSS accuracy and 1 ms response, meeting IEC 60601-2-12 requirements for critical care devices.

Use Scenario: Closed-loop regulation of fluid pressure in chemical dosing systems and HVAC chillers.

IC Role / Device Role / Timing Role: Primary feedback sensor in PID-controlled pressure loops, interfaced to industrial PLC analog inputs via signal conditioning.

Use Value: Provides stable, drift-free absolute pressure data over −40 to +125 °C ambient, supporting 24/7 operation in factory-floor environments.

Pump/Motor ControlWhite Goods

Use Scenario: Detection of pump cavitation, filter clogging, or flow loss in HVAC circulation pumps and industrial compressors.

IC Role / Device Role / Timing Role: Absolute pressure monitor placed upstream/downstream of pump to infer differential head and detect stall conditions.

Use Value: Delivers 1 ms response and ±0.5%VFSS offset stability, enabling real-time fault detection before mechanical failure occurs.

Use Scenario: Water level and detergent dispensing control in front-load washing machines and dishwashers.

IC Role / Device Role / Timing Role: Absolute pressure sensor measuring hydrostatic column height in sealed tub assemblies to infer water volume.

Use Value: Operates reliably in humid, high-vibration environments with epoxy unibody sealing and fluorosilicone die protection.

Equivalent & Alternatives

The following parts are listed as comparable options for similar absolute pressure sensing applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
MPXV5100GPSmall-outline 8-lead package (98ASB17757C); same 0–100 kPa range but gauge configuration; lacks absolute reference port.Requires external vacuum reference for absolute-equivalent use; not drop-in for MPX5100AP's unibody mounting or port orientation.Select only if board layout supports SOIC-8 and system design accommodates gauge-based absolute derivation.
MPX5700APHigher accuracy (±1.5%VFSS); wider temp range (−40 to +150 °C); same unibody 6-pin package and 0–100 kPa absolute range.Valid for automotive under-hood and extended-temperature industrial use where tighter error budget is required.Choose when enhanced accuracy and extended thermal performance justify cost premium over MPX5100AP.

Compared with MPX5100AP, MPXV5100GP requires redesign of mechanical interface and signal conditioning due to gauge topology and SOIC packaging, while MPX5700AP offers direct drop-in replacement with improved accuracy and thermal margin-making it suitable for next-generation designs demanding higher confidence in absolute pressure readings.

Availability

MPX5100AP is available at Aetrix Electronics and suitable for patient monitoring, process control, and pump/motor control applications requiring stable component supply, long-lifecycle support, and traceable sourcing from authorized channels.

Supply support for MPX5100AP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT markets.

The MPX5100AP belongs to NXP's legacy MPX5000-series integrated pressure sensors, designed specifically for microcontroller-based systems needing calibrated, temperature-compensated analog pressure outputs without external signal conditioning.

FAQ

What is the pressure type and range supported by the MPX5100AP?

The MPX5100AP is an absolute pressure sensor with a specified range of 0 to 100 kPa. It measures pressure relative to full vacuum and is qualified for use with dry air as the pressure medium. Its transfer function is VOUT = VS × (P × 0.009 − 0.095), and it maintains ±2.5%VFSS accuracy across 0–85 °C ambient temperature. This makes MPX5100AP suitable for barometric sensing and sealed-system absolute pressure monitoring where atmospheric reference is not available.

Does the MPX5100AP require external calibration or trimming?

No, the MPX5100AP does not require external calibration or trimming. It integrates on-chip temperature compensation and factory calibration for offset, full-scale output, and span across its operating temperature range. The device delivers a ratiometric analog output that scales directly with supply voltage, eliminating the need for external thermistors, DACs, or software correction tables. All calibration data is embedded during manufacturing, so MPX5100AP operates as a plug-and-play sensor when powered within its 4.75–5.25 V supply range.

What are the valid supply voltage and current requirements for MPX5100AP?

The MPX5100AP operates from a nominal 5 V supply with a specified range of 4.75 V to 5.25 V DC. At VS = 5.0 V and TA = 25 °C, its typical supply current is 7.0 mA, with a maximum of 10 mA. The device is ratiometric, meaning its output voltage scales linearly with supply voltage-so variations within the specified excitation range do not degrade measurement accuracy. Decoupling requires a 1.0 μF bulk capacitor and a 0.01 μF ceramic capacitor placed close to the VS and GND pins, per NXP's recommended circuit in Figure 7 of the datasheet.

How is the MPX5100AP pinout configured and what are the unused pins?

The MPX5100AP uses a 6-lead unibody package (case 98ASB42796B) with three functional pins: Pin 1 is VOUT, Pin 2 is GND, and Pin 3 is VS. Pins 4, 5, and 6 are labeled DNC (Do Not Connect) and are internal device connections-these must remain unconnected to any external circuitry or ground. This pinout is explicitly documented in Figure 2 and Table 1 of the MPX5100 datasheet Rev. 14, and applies exclusively to the MPX5100AP/DP/GP variants in the unibody package.

Can MPX5100AP be used with pressure media other than dry air?

NXP specifies that MPX5100AP operating characteristics and long-term reliability are validated using dry air as the pressure medium. Media other than dry air-including moisture, oils, solvents, or corrosive gases-may degrade sensor performance or cause irreversible damage to the fluorosilicone gel, die, or wire bonds. For non-dry-air applications, NXP recommends contacting factory support to evaluate media compatibility. Using unqualified media voids warranty and may result in drift, offset shift, or premature failure of the MPX5100AP.

MPX5100AP Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MPX5100
Package/Case:
6-SIP Module
Packaging:
Tray
Product Status:
Obsolete
Applications:
Board Mount
Pressure Type:
Absolute
Operating Pressure:
2.18PSI ~ 16.68PSI (15kPa ~ 115kPa)
Output Type:
Analog Voltage
Output:
0.2 V ~ 4.7 V
Accuracy:
±2.5%
Voltage - Supply:
4.75V ~ 5.25V
Port Size:
Male - 0.19" (4.93mm) Tube
Port Style:
Barbed
Features:
Temperature Compensated
Termination Style:
PC Pin
Maximum Pressure:
58.02PSI (400kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Through Hole
Supplier Device Package:
-

MPX5100AP FAQ

1.How can I place an order for MPX5100AP through Aetrix?

Please submit a Request for Quotation (RFQ) for MPX5100AP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MPX5100AP reliable?

The price and inventory of MPX5100AP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX5100AP is usually 5 days.

3.What payment methods are accepted for MPX5100AP?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX5100AP transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MPX5100AP?

MPX5100AP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MPX5100AP order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MPX5100AP?

For technical support, including MPX5100AP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX5100AP requirements.

6.How does Aetrix verify that MPX5100AP is sourced from the original manufacturer or authorized distributors?

All MPX5100AP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX5100AP meets industry standards.

7.What is the process for return or replacement of MPX5100AP?

All MPX5100AP units undergo pre-shipment inspection (PSI). If there is an issue with MPX5100AP, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MPX5100AP part is unused and in its original packaging.

Return procedure for MPX5100AP:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MPX5100AP Tags

  • MPX5100AP
  • MPX5100AP PDF
  • MPX5100AP Datasheet
  • MPX5100AP Specifications
  • MPX5100AP Images
  • NXP Semiconductors
  • NXP Semiconductors MPX5100AP
  • Buy MPX5100AP
  • MPX5100AP Price
  • MPX5100AP Distributor
  • MPX5100AP Supplier
  • MPX5100AP Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER