NXP Semiconductors MPX5100DP
- Part No.:
- MPX5100DP
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 6-SIP Module
- Datasheet:
-
MPX5100DP.pdf
- Description:
- SENSOR 14.5PSID 0.19" 4.7V
- Quantity:
- Payment:

- Shipping:

Inventory:1,800
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPX5100DP from NXP Semiconductors is a monolithic silicon piezoresistive differential pressure sensor with 0–100 kPa full-scale range, ±2.5% accuracy over 0–85 °C, ratiometric 4.75–5.25 V supply operation, and 45 mV/kPa sensitivity. It delivers a high-level analog output (0.088–4.813 V) proportional to applied differential pressure and is used in microcontroller-based pump control, medical patient monitoring, and industrial process sensing.
For engineers reviewing the MPX5100DP datasheet, MPX5100DP pinout, MPX5100DP application, or MPX5100DP equivalent, key selection considerations include its unibody epoxy package, dual-port differential configuration, on-chip temperature compensation, and compatibility with 5 V A/D interfaces in embedded sensing systems.
Technical Context
The MPX5100DP integrates a patented silicon shear-stress strain gauge with thin-film metallization and bipolar processing to generate a linear, temperature-compensated analog voltage output. Its internal architecture includes two gain stages and ground-reference shift circuitry, enabling stable operation across –40 to +125 °C.
It operates ratiometrically - output voltage scales directly with supply voltage (VS), supporting accurate measurement without external reference. The device uses fluorosilicone gel encapsulation to isolate the die while transmitting pressure to the diaphragm, and requires dry air as the pressure medium for specified performance and reliability.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0 to 100 kPa differential - supports precise low-pressure measurement in HVAC, medical, and industrial flow control. |
| Accuracy | ±2.5% of full-scale span (VFSS) over 0–85 °C - includes linearity, temperature hysteresis, pressure hysteresis, TcSpan, and TcOffset contributions. |
| Supply Voltage | 4.75–5.25 VDC - ratiometric operation ensures output scaling matches VS, simplifying A/D conversion in 5 V systems. |
| Output Voltage Range | 0.088 V (min offset) to 4.813 V (max full-scale) at VS = 5.0 V - provides >4.5 V span for high SNR into 12-bit+ ADCs. |
| Sensitivity | 45 mV/kPa - enables direct interpretation of output change per kPa without gain calibration in many applications. |
| Response Time | 1.0 ms (10% to 90%) - suitable for dynamic pressure monitoring including motor/pump transient detection. |
| Operating Temp. | –40 to +125 °C - wide range supports under-hood automotive, industrial, and medical equipment deployment. |
Pinout & Package
MPX5100DP uses the 6-lead unibody package (case 98ASB42797B), featuring an epoxy-encapsulated silicon die with dual pressure ports and fluorosilicone gel protection. The package is surface-mountable with a defined footprint per NXP's mechanical drawings.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | VOUT | Analog output voltage proportional to differential pressure - connects directly to MCU A/D input with optional RC filtering. |
| 2 | GND | Analog ground reference - must be tied to system AGND with low-impedance path to minimize noise coupling. |
| 3 | VS | Positive supply input (4.75–5.25 V) - requires local 0.01 µF + 1.0 µF decoupling per Figure 7 of datasheet. |
| 4–6 | DNC | Internal connections only - must remain unconnected; no PCB traces or vias allowed on these pads. |
Key Features
| Feature | Design Value |
|---|---|
| Piezoresistive silicon shear-stress gauge | Enables high stability and low hysteresis vs. conventional Wheatstone bridges, improving long-term repeatability in cyclic pressure applications. |
| On-chip temperature compensation | Eliminates need for external thermistor or digital correction - maintains ±2.5% VFSS accuracy across 0–85 °C without firmware overhead. |
| Dual-port differential configuration | Allows true differential pressure measurement (P1 > P2) with isolated media paths - essential for flow, filter monitoring, and leak detection. |
| Epoxy unibody construction | Provides mechanical robustness and environmental sealing in non-corrosive gas/air applications, reducing assembly complexity vs. gasketed modules. |
| Ratiometric output | Output voltage scales linearly with VS - enables use with shared 5 V rail and eliminates need for precision voltage references in cost-sensitive designs. |
Applications
| Medical Patient Monitoring | Industrial Pump Control |
|---|---|
|
Use Scenario: Continuous airway pressure sensing in portable ventilators and CPAP devices. IC Role / Device Role / Timing Role: Differential pressure transducer measuring pressure drop across air filters or across inspiratory/expiratory limbs. Use Value: Delivers 1.0 ms response and ±2.5% accuracy to support real-time breath cycle detection and alarm triggering within FDA-cleared systems. |
Use Scenario: Closed-loop feedback for variable-speed centrifugal pumps in HVAC and water circulation systems. IC Role / Device Role / Timing Role: Primary pressure sensor detecting system head pressure to modulate pump speed via MCU PWM output. Use Value: 45 mV/kPa sensitivity and ratiometric output enable direct ADC interfacing with <1 LSB error at 12-bit resolution using standard 5 V rails. |
| Process Control Automation | White Goods Pressure Switching |
|
Use Scenario: Filter clogging detection and flow verification in compressed air distribution networks. IC Role / Device Role / Timing Role: Differential sensor mounted across filter housing to monitor ΔP rise over time. Use Value: –40 to +125 °C operating range and epoxy unibody package ensure reliable operation in factory-floor environments with thermal cycling and vibration. |
Use Scenario: Water level and drum pressure sensing in front-load washing machines and dishwashers. IC Role / Device Role / Timing Role: Gauge-mode pressure switch replacing mechanical diaphragm switches for detergent dosing and spin-balance control. Use Value: 0.088–4.813 V output swing provides wide margin for comparator threshold setting and reduces false triggers from EMI or supply ripple. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar differential pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPXV5100DP | Same 0–100 kPa range and ±2.5% accuracy, but in 8-lead small-outline package (98ASA99255D) with different pinout and port orientation. | Designed for space-constrained PCB layouts requiring dual-port side-entry; lacks unibody epoxy ruggedness of MPX5100DP. | Select MPXV5100DP when board area is limited and reflow-compatible SMT placement is required; verify port alignment and decoupling layout per AN1646. |
| MPX5010DP | Lower 0–10 kPa range, same unibody package and pinout, ±2.5% accuracy, but reduced sensitivity (450 mV/kPa) and narrower temp range (0–85 °C). | Optimized for high-resolution low-pressure applications like respiratory flow meters - not suitable for 100 kPa system monitoring. | Choose MPX5010DP only when sub-10 kPa resolution is critical; MPX5100DP remains preferred for general-purpose 0–100 kPa differential sensing. |
Compared with MPXV5100DP, MPX5100DP offers superior mechanical robustness and simplified layout due to its unibody construction and 3-active-pin interface; compared with MPX5010DP, it extends full-scale range tenfold while maintaining identical accuracy and interface compatibility - making MPX5100DP the optimal choice for mid-range industrial and medical differential pressure tasks.
Availability
MPX5100DP is available at Aetrix Electronics and suitable for medical patient monitoring, industrial pump control, and process automation requiring stable component supply, long-lifecycle assurance, and traceable sourcing from authorized channels.
Supply support for MPX5100DP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT applications.
The MPX5100DP belongs to NXP's legacy MPX series of integrated silicon pressure sensors, designed specifically for microcontroller-based analog sensing in cost-sensitive, high-reliability embedded systems where on-chip compensation and unibody ruggedness are critical.
FAQ
What is the maximum pressure rating for MPX5100DP?
The MPX5100DP has a maximum pressure rating of 400 kPa, well above its 0–100 kPa full-scale operating range. This overpressure capability protects the sensor from transient spikes during system startup, valve switching, or fault conditions without permanent damage or calibration shift - a key reliability feature confirmed in Table 3 of the MPX5100 Rev. 14 datasheet.
Does MPX5100DP require external temperature compensation?
No, MPX5100DP does not require external temperature compensation. It features fully integrated on-chip temperature compensation and calibration, delivering ±2.5% VFSS accuracy over 0–85 °C without additional components or firmware correction - a core design advantage documented in Section 3 and Figure 5 of the MPX5100 datasheet.
Can MPX5100DP be used with a 3.3 V microcontroller ADC?
MPX5100DP is specified for 4.75–5.25 V supply only and is not rated for 3.3 V operation. Using it with a 3.3 V rail violates absolute maximum ratings and degrades accuracy, output swing, and stability. For 3.3 V systems, consider NXP's MPXV7002 or MP3V5050 - MPX5100DP must be powered from a dedicated 5 V source even when interfacing with 3.3 V MCUs.
What is the pressure media compatibility of MPX5100DP?
MPX5100DP is qualified for use with dry air as the pressure medium. Other media - including liquids, humid air, oils, or corrosive gases - may degrade fluorosilicone gel integrity or cause long-term drift. NXP explicitly states that non-dry-air media "may have adverse effects on sensor performance and long-term reliability," and recommends contacting factory support before qualifying MPX5100DP in alternative media.
How is the differential port orientation identified on MPX5100DP?
For MPX5100DP, the Pressure (P1) side is identified by the side bearing the part marking (e.g., "MPX5100DP") per Table 4.1 in the datasheet. P1 must be connected to the higher-pressure port and P2 to the lower-pressure or reference port; applying reverse differential pressure (P2 > P1) is not supported and may affect accuracy or longevity of the MPX5100DP.
MPX5100DP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPX5100
- Package/Case:
- 6-SIP Module
- Packaging:
- Tray
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Differential
- Operating Pressure:
- 14.5PSI (100kPa)
- Output Type:
- Analog Voltage
- Output:
- 0.2 V ~ 4.7 V
- Accuracy:
- ±2.5%
- Voltage - Supply:
- 4.75V ~ 5.25V
- Port Size:
- Male - 0.19" (4.93mm) Tube, Dual
- Port Style:
- Barbed
- Features:
- Temperature Compensated
- Termination Style:
- PC Pin
- Maximum Pressure:
- 58.02PSI (400kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- -
MPX5100DP FAQ
1.How can I place an order for MPX5100DP through Aetrix?
Please submit a Request for Quotation (RFQ) for MPX5100DP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPX5100DP reliable?
The price and inventory of MPX5100DP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX5100DP is usually 5 days.
3.What payment methods are accepted for MPX5100DP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX5100DP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPX5100DP?
MPX5100DP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPX5100DP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPX5100DP?
For technical support, including MPX5100DP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX5100DP requirements.
6.How does Aetrix verify that MPX5100DP is sourced from the original manufacturer or authorized distributors?
All MPX5100DP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX5100DP meets industry standards.
7.What is the process for return or replacement of MPX5100DP?
All MPX5100DP units undergo pre-shipment inspection (PSI). If there is an issue with MPX5100DP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPX5100DP part is unused and in its original packaging.
Return procedure for MPX5100DP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPX5100DP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…