Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

NXP Semiconductors MPX5100GP

Part No.:
MPX5100GP
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
6-SIP Module
Datasheet:
AetrixMPX5100GP.pdf
Description:
SENSOR 14.5PSIG 0.19" 4.7V
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:1,069

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MPX5100GP from NXP Semiconductors is a monolithic silicon piezoresistive pressure sensor in unibody epoxy package, configured for gauge pressure measurement (0 to 100 kPa), delivering ratiometric analog output (0.2–4.7 V at 5 V supply), ±2.5% full-scale accuracy over 0–85 °C, and 1 ms response time - used in medical patient monitoring and industrial pump control systems.

For engineers reviewing the MPX5100GP datasheet, MPX5100GP pinout, MPX5100GP application, or MPX5100GP equivalent, this page delivers verified technical context, validated pin functions, confirmed operating parameters, and real-world use-case implementation guidance for microcontroller-based pressure sensing designs.

Technical Context

The MPX5100GP integrates a patented silicon shear-stress strain gauge with on-chip thin-film temperature compensation and dual-stage gain amplification. Its output follows VOUT = VS × (0.009 × P + 0.04) ± (2.5% × VFSS × temperature multiplier), enabling direct A/D interfacing without external signal conditioning.

It operates ratiometrically across 4.75–5.25 V supply, draws ≤10 mA, and features internal decoupling support via recommended 1.0 μF/0.01 μF capacitor network. The unibody package isolates the die with fluorosilicone gel and uses dry air as qualified pressure media.

Key Specifications

ParameterValue and Actual Design Meaning
Pressure Range0 to 100 kPa gauge - supports standard pneumatic control and biomedical pressure thresholds.
Output Voltage0.20 V min / 4.70 V typ at full scale - compatible with 5 V ADC reference without level-shifting.
Accuracy±2.5% of full-scale span (VFSS) - includes linearity, temp hysteresis, pressure hysteresis, TcSpan, and TcOffset.
Response Time1.0 ms (10% to 90%) - enables real-time dynamic pressure capture in motor control loops.
Supply Voltage4.75–5.25 VDC - ratiometric operation ensures output stability against supply drift.
Operating Temp−40 to +125 °C - validated for harsh industrial environments and medical device sterilization cycles.
Sensitivity45 mV/kPa - provides high-resolution analog signal for 12-bit ADCs with ≥1 kPa resolution.

Pinout & Package

MPX5100GP uses the 6-lead unibody epoxy package (case 98ASB42796B), with port on the same side as the marking. Pins 4–6 are internal connections and must remain unconnected.

Pin/TerminalCircuit RoleDesign Meaning
1VOUTAnalog output voltage proportional to applied gauge pressure - directly interfaces to MCU ADC input.
2GNDGround reference for both supply and output - requires low-impedance connection to minimize noise coupling.
3VSPositive supply input (4.75–5.25 V) - must be decoupled with 1.0 μF and 0.01 μF capacitors per datasheet Figure 7.
4DNCInternal connection - no external trace, pad, or soldering allowed.
5DNCInternal connection - floating; must not be tied to GND or any other node.
6DNCInternal connection - electrically isolated from external circuitry.

Key Features

FeatureDesign Value
Piezoresistive silicon shear-stress gaugeEnables stable, low-drift pressure transduction without moving parts or MEMS cavities.
On-chip temperature compensationEliminates need for external thermistor networks or digital calibration in 0–85 °C range.
Epoxy unibody constructionProvides mechanical robustness and media isolation using fluorosilicone gel encapsulation.
Ratiometric analog outputOutput scales linearly with supply voltage - simplifies system-level power rail tolerance management.
Gauge pressure configurationSingle-port design referenced to ambient - ideal for flow sensing, tank level, and HVAC differential monitoring.

Applications

Patient MonitoringPump/Motor Control

Use Scenario: Continuous non-invasive blood pressure and respiratory airflow tracking in bedside monitors and portable ventilators.

IC Role / Device Role / Timing Role: Primary gauge pressure transducer converting pneumatic signals into calibrated analog voltage for ADC sampling.

Use Value: Delivers ±2.5% VFSS accuracy and 1 ms response - meets IEC 60601-2-51 clinical pressure measurement requirements.

Use Scenario: Closed-loop feedback for centrifugal pumps in HVAC and water circulation systems.

IC Role / Device Role / Timing Role: Real-time discharge pressure sensing to regulate motor speed via PWM-driven inverter.

Use Value: Ratiometric output and −40 to +125 °C operation ensure reliable performance across thermal cycling and voltage ripple.

Process ControlWhite Goods

Use Scenario: Pressure monitoring in industrial pneumatic actuators and compressed air distribution lines.

IC Role / Device Role / Timing Role: Analog front-end sensor providing linear 0–100 kPa signal to PLC analog input modules.

Use Value: Unibody epoxy package withstands vibration and humidity; 400 kPa max pressure rating prevents overpressure damage.

Use Scenario: Water level detection and detergent dispensing control in washing machines and dishwashers.

IC Role / Device Role / Timing Role: Low-cost gauge sensor measuring hydrostatic head pressure in sealed reservoirs.

Use Value: 0.2–4.7 V output range matches 5 V MCU ADCs; easy-to-use chip carrier simplifies SMT assembly.

Equivalent & Alternatives

The following parts are listed as comparable options for similar gauge pressure sensing applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
MPXV5100GPSmall-outline 8-lead package (98ASA99303D); identical electrical specs but different footprint and port orientation.Requires PCB redesign due to 8-pin SOIC layout and side-port geometry - not drop-in compatible.Select MPXV5100GP only when board space constraints favor SOIC or when side-port mounting is required.
MPX5010GPLower pressure range (0–10 kPa); same unibody package and pinout; ±2.5% accuracy retained.Optimized for low-pressure applications like air flow sensing - insufficient for 100 kPa pump or process use cases.Choose MPX5010GP only when target pressure stays below 15 kPa and higher resolution at low end is critical.

Compared with MPX5100GP, MPXV5100GP offers identical sensing performance in a surface-mount SOIC package requiring layout change, while MPX5010GP trades pressure range for enhanced low-end sensitivity - neither is pin-compatible, and selection depends strictly on mechanical integration and pressure span requirements.

Availability

MPX5100GP is available at Aetrix Electronics and suitable for patient monitoring devices, industrial pump control systems, and white goods requiring stable component supply with long-term manufacturability and consistent calibration traceability.

Supply support for MPX5100GP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

NXP Semiconductors is a global semiconductor leader focused on secure connectivity solutions for automotive, industrial, and IoT applications.

The MPX5100GP belongs to NXP's integrated pressure sensor product line, designed specifically for microcontroller-based analog sensing in medical, industrial, and appliance systems where reliability, temperature stability, and ease of integration are critical.

FAQ

What pressure type does the MPX5100GP measure?

The MPX5100GP measures gauge pressure - meaning it references ambient atmospheric pressure as zero. It has a single pressure port and outputs a voltage proportional to pressure applied relative to atmosphere, covering 0 to 100 kPa. This makes MPX5100GP suitable for applications such as tank level sensing, airflow monitoring, and pump discharge pressure feedback where absolute vacuum reference is not required.

What is the supply voltage range for reliable operation of the MPX5100GP?

The MPX5100GP operates reliably across a supply voltage range of 4.75 V to 5.25 V DC. Its ratiometric architecture ensures that output voltage scales linearly with supply voltage, maintaining measurement accuracy even with minor supply fluctuations. Operating outside this range may degrade accuracy or cause instability, and the datasheet specifies 5.0 V ± 0.25 V as the nominal condition for all key specifications including full-scale output and accuracy.

Does the MPX5100GP require external temperature compensation?

No, the MPX5100GP does not require external temperature compensation. It integrates on-chip temperature compensation circuitry that corrects for offset and span drift across 0 to 85 °C, contributing to its ±2.5% full-scale accuracy specification. This eliminates the need for external thermistors or calibration firmware - the MPX5100GP delivers factory-calibrated analog output directly usable by an MCU's ADC without additional signal conditioning.

Can the MPX5100GP be used with a 3.3 V microcontroller ADC?

The MPX5100GP is specified for 4.75–5.25 V supply and produces a 0.2–4.7 V output range under those conditions. Using it with a 3.3 V MCU ADC requires either level-shifting or supply regulation - direct connection risks exceeding the ADC's input voltage rating and damaging the MCU. For native 3.3 V compatibility, consider NXP's MPXV5004DP or MPXV7002DP, which are explicitly rated for 3.3 V operation and produce scaled output ranges.

What is the maximum pressure the MPX5100GP can withstand without damage?

The MPX5100GP has a maximum pressure rating of 400 kPa, as defined in its absolute maximum ratings table. Exceeding this pressure may cause permanent mechanical deformation or electrical degradation of the silicon sensing element. While the device is calibrated for 0–100 kPa operation, its overpressure capability provides safety margin during transient spikes - however, sustained exposure above 100 kPa will invalidate accuracy and long-term reliability claims for MPX5100GP.

MPX5100GP Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MPX5100
Package/Case:
6-SIP Module
Packaging:
Tray
Product Status:
Active
Applications:
Board Mount
Pressure Type:
Vented Gauge
Operating Pressure:
14.5PSI (100kPa)
Output Type:
Analog Voltage
Output:
0.2 V ~ 4.7 V
Accuracy:
±2.5%
Voltage - Supply:
4.75V ~ 5.25V
Port Size:
Male - 0.19" (4.93mm) Tube
Port Style:
Barbed
Features:
Temperature Compensated
Termination Style:
PC Pin
Maximum Pressure:
58.02PSI (400kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Through Hole
Supplier Device Package:
-

MPX5100GP FAQ

1.How can I place an order for MPX5100GP through Aetrix?

Please submit a Request for Quotation (RFQ) for MPX5100GP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MPX5100GP reliable?

The price and inventory of MPX5100GP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX5100GP is usually 5 days.

3.What payment methods are accepted for MPX5100GP?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX5100GP transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MPX5100GP?

MPX5100GP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MPX5100GP order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MPX5100GP?

For technical support, including MPX5100GP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX5100GP requirements.

6.How does Aetrix verify that MPX5100GP is sourced from the original manufacturer or authorized distributors?

All MPX5100GP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX5100GP meets industry standards.

7.What is the process for return or replacement of MPX5100GP?

All MPX5100GP units undergo pre-shipment inspection (PSI). If there is an issue with MPX5100GP, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MPX5100GP part is unused and in its original packaging.

Return procedure for MPX5100GP:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MPX5100GP Tags

  • MPX5100GP
  • MPX5100GP PDF
  • MPX5100GP Datasheet
  • MPX5100GP Specifications
  • MPX5100GP Images
  • NXP Semiconductors
  • NXP Semiconductors MPX5100GP
  • Buy MPX5100GP
  • MPX5100GP Price
  • MPX5100GP Distributor
  • MPX5100GP Supplier
  • MPX5100GP Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER