NXP Semiconductors MPX5100GSX

Part No.:
MPX5100GSX
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
6-SIP Module
Datasheet:
AetrixMPX5100GSX.pdf
Description:
SENSOR 14.5PSIG 0.19" 4.7V
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:1,712

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MPX5100GSX from NXP Semiconductors is a monolithic silicon piezoresistive pressure sensor in unibody package, configured for gauge pressure measurement (0–100 kPa), delivering ratiometric analog output (0.2 V to 4.7 V at 5 V supply), ±2.5% full-scale accuracy over 0–85 °C, and 1 ms response time. It serves as a primary pressure transduction element in microcontroller-based medical and industrial control systems.

For engineers reviewing the MPX5100GSX datasheet, MPX5100GSX pinout, MPX5100GSX application, or MPX5100GSX equivalent, this page delivers verified technical context, validated pin functions, real-world use cases, and two confirmed alternative parts with documented functional and packaging differences.

Technical Context

The MPX5100GSX integrates a patented silicon shear-stress strain gauge with on-chip thin-film temperature compensation and dual-stage gain amplification. Its transfer function is VOUT = VS × (0.009 × P + 0.04), making output strictly ratiometric to supply voltage and linear with applied pressure.

It operates across –40 to +125 °C, supports 4.75–5.25 VDC excitation, draws ≤10 mA supply current, and features fluorosilicone gel die protection for environmental robustness. The device is media-rated for dry air only; non-dry-air media require factory consultation.

Key Specifications

Parameter Value and Actual Design Meaning
Pressure Range 0–100 kPa gauge - defines full-scale operating span for calibrated analog output.
Output Voltage Range 0.20–4.70 VDC at VS = 5.0 V - provides 4.5 V full-scale span compatible with 5 V ADC reference rails.
Accuracy ±2.5 %VFSS over 0–85 °C - includes linearity, temperature hysteresis, pressure hysteresis, TcSpan, and TcOffset contributions.
Response Time 1.0 ms (10%–90%) - enables real-time pressure monitoring in dynamic pump/motor control loops.
Supply Voltage 4.75–5.25 VDC - ensures stable ratiometric operation within standard 5 V system rails.
Sensitivity 45 mV/kPa - yields ~4.5 V output at 100 kPa, enabling direct interface to 12-bit+ ADCs without gain staging.
Operating Temperature –40 to +125 °C - supports deployment in automotive engine bays and industrial enclosures without external thermal management.

Pinout & Package

MPX5100GSX uses the 6-lead unibody package (case 98ASB42796B), featuring an epoxy-encapsulated silicon die with stainless steel metal cover and integrated port for gauge pressure sensing. The package is surface-mountable with self-aligning footprint per NXP-recommended land pattern.

Pin Circuit Role Design Meaning
1 VOUT Analog output voltage proportional to applied pressure; requires 1 µF decoupling capacitor to ground per Figure 7.
2 GND Analog ground reference for internal amplifier stages; must be connected to low-noise system ground plane.
3 VS Positive supply input (4.75–5.25 VDC); requires 0.01 µF ceramic + 470 pF film capacitor filtering per Figure 7.
4–6 DNC Internally connected; must remain unconnected - no external tie to GND, VS, or signal traces.

Key Features

Feature Design Value
Piezoresistive silicon shear-stress gauge Enables high repeatability and low hysteresis (<±0.5 %VFSS offset stability after 1000-hour stress test).
On-chip temperature compensation Eliminates need for external thermistor or digital calibration in 0–85 °C medical and appliance applications.
Ratiometric output architecture Preserves measurement integrity when sharing 5 V rail with microcontroller ADC reference, reducing supply noise sensitivity.
Dual-port-capable unibody construction Supports gauge-mode operation with one side exposed to ambient (P2) and one side to process pressure (P1).
Epoxy unibody encapsulation Provides mechanical durability and moisture resistance in white goods and patient monitoring housings.

Applications

Medical Patient Monitoring Industrial Pump Control

Use Scenario: Continuous non-invasive blood pressure and respiratory flow monitoring in portable clinical devices.

IC Role / Device Role / Timing Role: Primary gauge pressure transducer converting pneumatic pressure into calibrated analog voltage for microcontroller ADC sampling.

Use Value: ±2.5% accuracy and 1 ms response enable reliable systolic/diastolic detection and breath cycle timing without post-processing correction.

Use Scenario: Closed-loop feedback for centrifugal and diaphragm pumps in HVAC and fluid handling systems.

IC Role / Device Role / Timing Role: Real-time differential pressure sensor measuring inlet/outlet delta-P to regulate motor speed and prevent cavitation.

Use Value: Ratiometric output and wide temperature range (–40 to +125 °C) ensure stable control under varying ambient and fluid temperatures.

Home Appliance Pressure Switching Process Control Transmitter Interface

Use Scenario: Water level and detergent dispensing logic in washing machines and dishwashers.

IC Role / Device Role / Timing Role: Gauge pressure switch replacement providing analog feedback for precise fill-level estimation and leak detection.

Use Value: 0.2–4.7 V output spans full 12-bit ADC range, enabling 0.025 kPa resolution for sub-millimeter water column detection.

Use Scenario: Local analog front-end for 4–20 mA loop-powered transmitters in chemical and food processing lines.

IC Role / Device Role / Timing Role: High-stability primary sensor element interfaced to conditioning ICs for HART or analog output stages.

Use Value: Fluorosilicone gel isolation and dry-air media rating ensure long-term reliability in clean, non-corrosive process environments.

Equivalent & Alternatives

The following parts are listed as comparable options for similar gauge pressure sensing applications.

Alternative Part Technical Difference Application Difference Selection Advice
MPXV5100GC6U Same 0–100 kPa gauge range and 45 mV/kPa sensitivity, but in 8-lead small-outline package (98ASB17757C) with different pinout and port orientation. Designed for space-constrained PCB layouts requiring side-port mounting; lacks unibody mechanical ruggedness of MPX5100GSX. Select when board area is limited and side-port mechanical integration is required; verify land pattern compatibility.
MPX5010DP Lower 0–10 kPa range, same unibody package, ±2.5% accuracy, but optimized for differential pressure with dual ports. Intended for low-pressure differential sensing (e.g., filter clogging, airflow), not gauge-mode ambient-referenced measurement. Select only for differential applications; not a functional substitute for MPX5100GSX's gauge configuration.

Compared with MPX5100GSX, MPXV5100GC6U offers identical electrical performance in a smaller, side-port SOIC package-ideal for compact designs-but sacrifices unibody mechanical robustness. MPX5010DP provides comparable accuracy and packaging but targets differential, not gauge, pressure ranges, limiting its applicability in ambient-referenced systems.

Availability

MPX5100GSX is available at Aetrix Electronics and suitable for medical patient monitoring, industrial pump control, and home appliance pressure switching requiring stable component supply, long-lifecycle support, and traceable sourcing.

Supply support for MPX5100GSX includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT applications.

The MPX5100GSX belongs to NXP's legacy MPX5000-series integrated pressure sensors, designed specifically for cost-sensitive, high-volume microcontroller-based systems requiring analog pressure feedback without external signal conditioning.

FAQ

What is the pressure type and range supported by the MPX5100GSX?

The MPX5100GSX is a gauge pressure sensor with a specified range of 0 to 100 kPa. It measures pressure relative to ambient atmospheric pressure using a single port exposed to the process medium, while the opposite side is vented to atmosphere. This configuration is confirmed in NXP's MPX5100 datasheet Rev. 14, Table 4 and ordering information section for MPX5100GP variants.

Does the MPX5100GSX require external calibration or temperature compensation?

No, the MPX5100GSX includes fully integrated on-chip temperature compensation and factory calibration. Its output remains within ±2.5% VFSS accuracy over 0–85 °C without external circuitry, as verified in Section 3 and Table 4 of the official datasheet. The device implements thin-film metallization and bipolar processing to achieve this self-contained performance.

What is the correct pinout and connection guidance for MPX5100GSX?

The MPX5100GSX uses a 6-pin unibody package (98ASB42796B) with pins 1–3 assigned to VOUT, GND, and VS respectively; pins 4–6 are DNC and must remain unconnected. Power supply decoupling requires a 0.01 µF ceramic capacitor between VS and GND, plus a 470 pF film capacitor, per Figure 7 in the MPX5100 datasheet.

Can MPX5100GSX be used with media other than dry air?

No - the MPX5100GSX is qualified and rated exclusively for dry air as the pressure medium. Use with other gases or liquids may degrade long-term reliability or cause irreversible damage due to fluorosilicone gel incompatibility. NXP explicitly states this limitation in Section 3 of the MPX5100 datasheet and advises contacting factory support for media-specific validation.

What is the warm-up time and output stability specification for MPX5100GSX?

The MPX5100GSX has a specified warm-up time of 20 ms - defined as the time required to meet output voltage specifications after pressure stabilization. Its offset stability is ±0.5 %VFSS after 1000 hours of pulsed pressure and temperature cycling, confirming suitability for long-duration deployments in white goods and industrial controllers.

MPX5100GSX Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MPX5100
Package/Case:
6-SIP Module
Packaging:
Tray
Product Status:
Obsolete
Applications:
Board Mount
Pressure Type:
Vented Gauge
Operating Pressure:
14.5PSI (100kPa)
Output Type:
Analog Voltage
Output:
0.2 V ~ 4.7 V
Accuracy:
±2.5%
Voltage - Supply:
4.75V ~ 5.25V
Port Size:
Male - 0.19" (4.93mm) Tube
Port Style:
Barbed
Features:
Temperature Compensated
Termination Style:
PC Pin
Maximum Pressure:
58.02PSI (400kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Through Hole
Supplier Device Package:
-

MPX5100GSX FAQ

1.How can I place an order for MPX5100GSX through Aetrix?

Please submit a Request for Quotation (RFQ) for MPX5100GSX on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MPX5100GSX reliable?

The price and inventory of MPX5100GSX are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX5100GSX is usually 5 days.

3.What payment methods are accepted for MPX5100GSX?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX5100GSX transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MPX5100GSX?

MPX5100GSX orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MPX5100GSX order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MPX5100GSX?

For technical support, including MPX5100GSX datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX5100GSX requirements.

6.How does Aetrix verify that MPX5100GSX is sourced from the original manufacturer or authorized distributors?

All MPX5100GSX products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX5100GSX meets industry standards.

7.What is the process for return or replacement of MPX5100GSX?

All MPX5100GSX units undergo pre-shipment inspection (PSI). If there is an issue with MPX5100GSX, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MPX5100GSX part is unused and in its original packaging.

Return procedure for MPX5100GSX:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MPX5100GSX Tags

  • MPX5100GSX
  • MPX5100GSX PDF
  • MPX5100GSX Datasheet
  • MPX5100GSX Specifications
  • MPX5100GSX Images
  • NXP Semiconductors
  • NXP Semiconductors MPX5100GSX
  • Buy MPX5100GSX
  • MPX5100GSX Price
  • MPX5100GSX Distributor
  • MPX5100GSX Supplier
  • MPX5100GSX Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER