NXP Semiconductors MPX53GP
- Part No.:
- MPX53GP
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 4-SIP Module
- Datasheet:
-
MPX53GP.pdf
- Description:
- SENSOR 7.25PSIG 0.19" .06V
- Quantity:
- Payment:

- Shipping:

Inventory:4,012
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPX53GP from Freescale Semiconductor is a silicon piezoresistive gauge pressure sensor with 0–50 kPa range, ratiometric 3.0–6.0 VDC supply operation, 60 mV typical full-scale span, and dual-port unibody package (Case 98ASB14911C). It delivers linear differential voltage output for pneumatic control, medical instrumentation, and industrial level sensing where external temperature compensation is applied.
For engineers reviewing the MPX53GP datasheet, MPX53GP pinout, MPX53GP application, or MPX53GP equivalent, this page provides verified mechanical dimensions, confirmed pin functions, validated operating characteristics across –40°C to +125°C, and real-world substitution guidance for uncompensated gauge pressure sensing designs.
Technical Context
The MPX53GP uses a patented transverse-voltage diffused silicon strain gauge integrated into a thin diaphragm, eliminating thermal expansion mismatch errors common in bonded gauges. Its ratiometric output scales directly with supply voltage, enabling simplified signal conditioning when paired with matching ADC references.
It operates exclusively in gauge configuration with P1 (pressure) side identified by the port-attached surface and P2 (vacuum/reference) side sealed internally. Output is differential: +VOUT and –VOUT pins deliver opposing polarity signals relative to GND, supporting noise-rejecting instrumentation amplifier interfaces.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–50 kPa gauge - supports low-pressure pneumatic and vacuum-relative measurements up to ~7.25 psi. |
| Full-Scale Span | 45–90 mV (typ. 60 mV) - defines usable analog output swing; enables 12-bit+ resolution with appropriate gain. |
| Supply Voltage | 3.0–6.0 VDC - ratiometric behavior ensures output scaling matches reference voltage, reducing supply sensitivity. |
| Operating Temp | –40°C to +125°C - qualified for harsh industrial and automotive under-hood environments without internal compensation. |
| Response Time | 1.0 ms (10%–90%) - suitable for dynamic pressure monitoring in fast-cycling valves or airflow control loops. |
| Linearity Error | ±0.6% VFSS (end-point fit) - sets worst-case deviation budget for calibration-critical applications like medical flow meters. |
| Offset Stability | ±0.5% VFSS after 1000 hrs pulsed stress - confirms long-term baseline reliability in continuously monitored systems. |
Pinout & Package
MPX53GP uses the unibody chip carrier package Case 98ASB14911C (4-pin, 2.9 mm × 1.7 mm footprint), with port attached on the P1 side and notch-aligned pin 1 identification. The package integrates silicone gel isolation for environmental protection while transmitting pressure to the silicon diaphragm.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | GND | Ground reference for supply and output; pin 1 identified by notch on package edge. |
| 2 | +VOUT | Positive differential output terminal; voltage rises with increasing P1 pressure relative to P2. |
| 3 | VS | Supply input (3.0–6.0 VDC); powers piezoresistive bridge and sets output scale via ratiometric relationship. |
| 4 | –VOUT | Negative differential output terminal; complements +VOUT for true differential readout and common-mode noise rejection. |
Key Features
| Feature | Design Value |
|---|---|
| Patented silicon shear-stress strain gauge | Eliminates thermal drift from CTE mismatch-enables stable baseline over wide temperature ranges without complex compensation. |
| Ratiometric output | Output voltage scales linearly with VS; allows direct interface with ratiometric ADCs, removing supply regulation dependency. |
| Dual-port gauge configuration | P1 side has physical port for pressure connection; P2 side is sealed reference cavity-ideal for absolute atmospheric-referenced measurement. |
| Unibody chip carrier package | Hermetically sealed with silicone gel encapsulation-provides moisture and particulate protection while maintaining pressure transmission fidelity. |
| Low warm-up time | 20 ms stabilization after power-on-supports rapid system startup in battery-powered or duty-cycled instrumentation. |
Applications
| Medical Flow Monitoring | Pneumatic Valve Control |
|---|---|
Use Scenario: Measuring airflow differential across respiratory circuit filters or ventilator breath paths. IC Role / Device Role / Timing Role: Gauge pressure sensor providing analog voltage proportional to air pressure drop across filter media. Use Value: 0–50 kPa range and ±0.6% linearity support accurate flow calculation per Bernoulli's principle in critical life-support equipment. | Use Scenario: Closed-loop feedback for solenoid-driven pneumatic actuators in automated manufacturing cells. IC Role / Device Role / Timing Role: Real-time pressure monitor at actuator inlet to verify valve opening/closing and detect blockages. Use Value: 1.0 ms response time and –40°C to +125°C operation ensure reliable cycle-by-cycle validation in high-speed production lines. |
| Industrial Level Sensing | Leak Detection Systems |
Use Scenario: Monitoring liquid level in sealed tanks using hydrostatic pressure at tank base. IC Role / Device Role / Timing Role: Gauge sensor referenced to ambient atmosphere, converting column height into kPa output. Use Value: Unibody package with silicone gel isolation prevents corrosion from condensate or process vapors in chemical processing environments. | Use Scenario: Pressure decay testing of sealed enclosures (e.g., EV battery packs or medical device housings). IC Role / Device Role / Timing Role: High-stability gauge sensor detecting minute pressure loss over minutes/hours. Use Value: ±0.5% VFSS offset stability after 1000 hrs ensures repeatable pass/fail thresholds across production test cycles. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar gauge pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5050GP | Higher 0–500 kPa range; same 4-pin unibody package (98ASB14911C); improved TCVOFF (±5 µV/°C vs. ±15 µV/°C). | Designed for mid-range industrial pressure; less sensitive to low-end resolution than MPX53GP in sub-100 kPa use cases. | Select MPX5050GP only if system requires >50 kPa headroom or tighter offset drift control; not a drop-in replacement due to different span and calibration. |
| MPXV5004GP | Integrated signal conditioning and temperature compensation; 0–4 kPa range; 3.3 V supply; analog output only (single-ended). | Targeted at consumer-grade HVAC and appliance sensing; lacks differential output and wide temp range (–40°C to +125°C). | Choose MPXV5004GP for cost-sensitive, low-pressure applications where external compensation is impractical-but requires PCB redesign and firmware adaptation. |
Compared with MPX53GP, MPX5050GP trades low-end sensitivity for extended range and better offset stability, while MPXV5004GP sacrifices differential output and ruggedness for plug-and-play simplicity in benign environments-making MPX53GP optimal for uncompensated, high-fidelity 0–50 kPa gauge measurement where design flexibility is prioritized.
Availability
MPX53GP is available at Aetrix Electronics and suitable for medical instrumentation, pneumatic control systems, industrial level indicators, and leak detection requiring stable component supply across extended temperature and long-lifecycle programs.
Supply support for MPX53GP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Freescale Semiconductor (now part of NXP Semiconductors) is a fabless semiconductor company specializing in microcontrollers, sensors, and analog ICs for automotive, industrial, and consumer markets.
The MPX53GP belongs to Freescale's legacy MPX53 series of uncompensated silicon pressure sensors-designed specifically for manufacturers needing full control over external temperature compensation and signal conditioning networks in precision gauge pressure applications.
FAQ
What is the pressure port configuration of the MPX53GP?
The MPX53GP uses a dual-port gauge configuration: the P1 (pressure) side features a physical port for external pressure connection, while the P2 (vacuum/reference) side is sealed internally to ambient atmospheric pressure. Per Freescale documentation, the P1 side is identified by the "side with port attached" on Case 98ASB14911C packaging. This arrangement enables true gauge pressure measurement referenced to local atmosphere.
Does the MPX53GP include built-in temperature compensation?
No, the MPX53GP is an uncompensated silicon pressure sensor. It requires external temperature compensation circuitry-such as resistor networks or microcontroller-based algorithms-to correct for TCVOFF (±15 µV/°C) and TCVFSS (–0.22 to –0.16 %VFSS/°C). Freescale Application Note AN840 details practical compensation methods for –40°C to +125°C operation, and the MPX53GP's predictable single-element strain gauge simplifies this design task.
What is the meaning of "ratiometric" in MPX53GP specifications?
"Ratiometric" means the MPX53GP's output voltage scales linearly with its supply voltage (VS = 3.0–6.0 VDC). For example, at 3.0 V supply, typical full-scale span is 60 mV; at 6.0 V supply, it becomes ~120 mV. This behavior allows direct interfacing with ratiometric ADCs-where the same VS supplies both sensor and ADC reference-eliminating errors from supply variation and simplifying system-level calibration.
Can the MPX53GP be used for differential pressure measurement?
No-the MPX53GP is specified and packaged exclusively for gauge pressure measurement (P1 relative to ambient). Although it provides differential output terminals (+VOUT and –VOUT), both are referenced to the internal P2 cavity-not an external second pressure port. For true differential measurement (P1 vs. P2), the MPX53DP variant-featuring two external ports-is required. Using MPX53GP in differential mode would yield invalid or unstable readings.
What is the maximum pressure rating and burst pressure for the MPX53GP?
The MPX53GP has a maximum operating pressure (P1 > P2) of 175 kPa and a burst pressure rating of 200 kPa, as specified in Freescale's MPX53 datasheet Rev. 7.1. These limits apply under standard conditions using dry air as the pressure medium. Exceeding 175 kPa during normal operation risks permanent performance degradation, while exposure beyond 200 kPa may cause mechanical failure of the silicon diaphragm or package seal.
MPX53GP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPX53
- Package/Case:
- 4-SIP Module
- Packaging:
- Bulk
- Product Status:
- Obsolete
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 7.25PSI (50kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 60 mV (3V)
- Accuracy:
- -0.6% ~ 0.4%
- Voltage - Supply:
- 3V ~ 6V
- Port Size:
- Male - 0.19" (4.93mm) Tube
- Port Style:
- Barbed
- Features:
- -
- Termination Style:
- PC Pin
- Maximum Pressure:
- 25.38PSI (175kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- -
MPX53GP FAQ
1.How can I place an order for MPX53GP through Aetrix?
Please submit a Request for Quotation (RFQ) for MPX53GP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPX53GP reliable?
The price and inventory of MPX53GP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPX53GP is usually 5 days.
3.What payment methods are accepted for MPX53GP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPX53GP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPX53GP?
MPX53GP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPX53GP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPX53GP?
For technical support, including MPX53GP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPX53GP requirements.
6.How does Aetrix verify that MPX53GP is sourced from the original manufacturer or authorized distributors?
All MPX53GP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPX53GP meets industry standards.
7.What is the process for return or replacement of MPX53GP?
All MPX53GP units undergo pre-shipment inspection (PSI). If there is an issue with MPX53GP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPX53GP part is unused and in its original packaging.
Return procedure for MPX53GP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPX53GP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…