NXP Semiconductors MPXM2051GS
- Part No.:
- MPXM2051GS
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 5-SMD Module, Top Port
- Datasheet:
-
MPXM2051GS.pdf
- Description:
- SENSOR 7.25PSIG 0.12" .04V 5MPAK
- Quantity:
- Payment:

- Shipping:

Inventory:3,929
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPXM2051GS from NXP Semiconductors is a gauge-type silicon piezoresistive pressure sensor delivering ratiometric voltage output proportional to applied pressure, with full-scale range of 0–50 kPa, ±0.3 %VFSS linearity, and on-chip temperature compensation over 0 °C to +85 °C. It serves as a primary analog sensing element in closed-loop pressure monitoring systems for medical diagnostics and industrial pump control.
For engineers reviewing the MPXM2051GS datasheet, MPXM2051GS pinout, MPXM2051GS application, or MPXM2051GS equivalent, this page provides verified technical context, calibrated performance parameters, package-validated terminal roles, and application-specific design value - all tied explicitly to the MPXM2051GST1 variant in MPAK (SOT1673-1) packaging.
Technical Context
The MPXM2051GS integrates a monolithic silicon diaphragm with embedded strain gauges and thin-film resistor networks, laser-trimmed for span/offset calibration and temperature compensation. Its differential Wheatstone bridge architecture delivers ratiometric output referenced to supply voltage (VS), enabling direct interface with ADCs without external reference scaling.
It operates as a gauge sensor with P1 (pressure side) exposed via ported MPAK package and P2 (vacuum side) sealed; output polarity is defined by P1 > P2 pressure differential. The device exhibits 1.0 ms response time, ±0.1 %VFSS pressure hysteresis, and stable offset within ±0.5 %VFSS after 1000-hour stress testing.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Full-scale pressure range | 0–50 kPa - defines usable linear sensing window for low-pressure applications like non-invasive blood pressure or liquid level detection. |
| Output type | Differential ratiometric voltage - +VOUT and –VOUT provide bridge output directly scalable to VS, simplifying analog front-end design. |
| Linearity error | ±0.3 %VFSS (end-point method) - ensures high accuracy across full scale without software correction in cost-sensitive systems. |
| Temperature compensation | 0 °C to +85 °C - enables reliable operation in medical and industrial environments without external thermal management. |
| Response time | 1.0 ms (10%–90%) - supports dynamic pressure monitoring in robotics and motor control feedback loops. |
| Supply voltage range | 10–16 Vdc - compatible with standard industrial 12 V rails and tolerant of minor fluctuations without output drift. |
| Offset voltage | ±1.0 mV at 0 kPa - enables precise zero-pressure baseline setting in calibration-critical applications. |
Pinout & Package
The MPXM2051GS is housed in an MPAK package (Case 1320A, SOT1673-1), featuring a ported gauge configuration with silicone-gel-isolated die and lead-frame construction optimized for media compatibility with dry clean air.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| GND | Reference ground | Common return path for supply and output circuitry; must be low-impedance to maintain ratiometric accuracy. |
| +VOUT | Bridge output positive | High-side output of Wheatstone bridge; used with –VOUT to extract differential signal rejecting common-mode noise. |
| VS | Power supply input | Excitation source for piezoresistive bridge; output scales linearly with VS, enabling supply-referenced measurement. |
| –VOUT | Bridge output negative | Low-side output of Wheatstone bridge; paired with +VOUT to deliver true differential voltage proportional to pressure. |
Key Features
| Feature | Design Value |
|---|---|
| Gauge ported configuration | Enables direct atmospheric reference for pressure-to-level conversion without vacuum plumbing or differential tubing. |
| On-chip temperature compensation | Eliminates need for external thermistor networks or digital compensation algorithms in 0–85 °C operating range. |
| Laser-trimmed span and offset | Reduces factory calibration effort and ensures consistent sensitivity (0.8 mV/kPa) and zero-point accuracy across production lots. |
| Ratiometric output | Allows use with unregulated 12 V supplies and simplifies system-level accuracy by tracking supply variations in both excitation and measurement. |
| MPAK surface-mount package | Supports automated assembly and provides mechanical robustness for integration into compact medical or robotic enclosures. |
Applications
| Level Indicators | Medical Diagnostics |
|---|---|
Use Scenario: Monitoring liquid height in tanks or IV bags using hydrostatic pressure. IC Role / Device Role / Timing Role: Primary analog pressure transducer converting column height to differential voltage output. Use Value: Delivers ±0.3 %VFSS linearity and 1.0 ms response, enabling real-time level tracking with minimal post-processing. |
Use Scenario: Non-invasive blood pressure measurement in portable sphygmomanometers. IC Role / Device Role / Timing Role: Gauge-sensing element capturing cuff pressure waveform during inflation/deflation cycles. Use Value: On-chip temperature compensation ensures clinical-grade repeatability across ambient conditions without recalibration. |
| Robotics | Pump/Motor Control |
Use Scenario: Force feedback in gripper end-effectors using air pressure in pneumatic actuators. IC Role / Device Role / Timing Role: Closed-loop pressure sensor providing real-time actuator load feedback to motion controller. Use Value: Ratiometric output and 10–16 Vdc supply range simplify integration with 12 V robot power buses and ADC interfaces. |
Use Scenario: Overpressure protection and flow regulation in centrifugal or peristaltic pumps. IC Role / Device Role / Timing Role: Safety-critical pressure monitor triggering shutdown if 50 kPa limit is exceeded. Use Value: 200 kPa overpressure rating and ±0.1 %VFSS hysteresis ensure long-term reliability under cyclic mechanical stress. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar gauge pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPXV5050GP | Same 50 kPa full-scale range but uses SOIC-8 package with integrated signal conditioning; outputs single-ended 0.2–4.7 V. | Requires no external amplifier but lacks differential output and has higher minimum supply (4.75 V). | Select when board space permits SOIC-8 and system requires simplified analog output without instrumentation amp stage. |
| SDX100G2 | 100 kPa range, same MPAK package and pinout; ±0.25 %VFSS linearity; 0–85 °C compensation. | Higher pressure capability suits HVAC or compressed air monitoring where 50 kPa is insufficient. | Select when application requires headroom above 50 kPa while retaining identical footprint and calibration workflow. |
Compared with MPXM2051GS, MPXV5050GP trades differential output and ratiometric flexibility for integrated signal conditioning, while SDX100G2 extends pressure range within the same MPAK form factor - making MPXM2051GS optimal for cost-sensitive, low-pressure, differential-readout designs requiring tight linearity and proven medical qualification.
Availability
MPXM2051GS is available at Aetrix Electronics and suitable for medical diagnostics, robotics, and pump/motor control applications requiring stable component supply, long-lifecycle support, and traceable sourcing for FDA-regulated or industrial safety-critical designs.
Supply support for MPXM2051GS includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT markets.
The MPXM2051GS belongs to NXP's legacy MPX-series pressure sensors, designed specifically for high-accuracy, low-power, analog-output gauge pressure measurement in portable and embedded medical and industrial equipment.
FAQ
What is the operating temperature range for the MPXM2051GS?
The MPXM2051GS is temperature-compensated from 0 °C to +85 °C, with full performance specifications guaranteed across that range. Its maximum operating temperature is +125 °C, but accuracy parameters such as linearity and offset stability apply only within the compensated range. The MPXM2051GS maintains ±0.3 %VFSS linearity and ±1.0 mV offset over 0–85 °C, making it suitable for medical and industrial environments without external thermal regulation.
Does the MPXM2051GS require external calibration?
No, the MPXM2051GS does not require external calibration for basic operation. Each MPXM2051GS unit undergoes laser trimming during manufacturing for precise span and offset calibration, including on-chip temperature compensation. While system-level calibration may improve absolute accuracy in high-precision applications, the MPXM2051GS delivers specified linearity (±0.3 %VFSS) and offset (±1.0 mV) without additional trimming or compensation circuitry.
What is the pressure port configuration of the MPXM2051GS?
The MPXM2051GS uses a gauge configuration with a single pressure port on the P1 side (identified by the ported side of the MPAK package), while the P2 side is sealed to vacuum. This allows the MPXM2051GS to measure pressure relative to ambient atmosphere - ideal for level indicators, pump monitoring, and non-invasive blood pressure devices. The port is compatible with dry clean air; other media require factory consultation per AN3728.
Can the MPXM2051GS be used with a 5 V supply?
No, the MPXM2051GS requires a minimum supply voltage of 10 Vdc and operates up to 16 Vdc. Its ratiometric output is specified only within that range; using 5 V will result in insufficient bridge excitation, degraded signal-to-noise ratio, and potential noncompliance with linearity or offset specs. For 5 V systems, consider alternatives like MPXV5050GP, which is rated for 4.75–5.25 V operation.
What is the meaning of "ratiometric" in the MPXM2051GS datasheet?
"Ratiometric" means the MPXM2051GS output voltage scales linearly with its supply voltage (VS). For example, if VS changes from 10 V to 12 V, both the full-scale span (e.g., 40 mV) and offset (e.g., 0 mV) scale proportionally - preserving measurement accuracy even with supply variation. This allows the MPXM2051GS to interface directly with ratiometric ADCs, eliminating the need for a separate voltage reference and reducing system component count.
MPXM2051GS Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPXM2051G
- Package/Case:
- 5-SMD Module, Top Port
- Packaging:
- Tube
- Product Status:
- Obsolete
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 7.25PSI (50kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 40 mV (10V)
- Accuracy:
- ±0.3%
- Voltage - Supply:
- 10V ~ 16V
- Port Size:
- Male - 0.12" (2.97mm) Tube
- Port Style:
- Barbless
- Features:
- Temperature Compensated
- Termination Style:
- Gull Wing
- Maximum Pressure:
- 29.01PSI (200kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 5-MPAK
MPXM2051GS FAQ
1.How can I place an order for MPXM2051GS through Aetrix?
Please submit a Request for Quotation (RFQ) for MPXM2051GS on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPXM2051GS reliable?
The price and inventory of MPXM2051GS are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPXM2051GS is usually 5 days.
3.What payment methods are accepted for MPXM2051GS?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPXM2051GS transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPXM2051GS?
MPXM2051GS orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPXM2051GS order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPXM2051GS?
For technical support, including MPXM2051GS datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPXM2051GS requirements.
6.How does Aetrix verify that MPXM2051GS is sourced from the original manufacturer or authorized distributors?
All MPXM2051GS products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPXM2051GS meets industry standards.
7.What is the process for return or replacement of MPXM2051GS?
All MPXM2051GS units undergo pre-shipment inspection (PSI). If there is an issue with MPXM2051GS, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPXM2051GS part is unused and in its original packaging.
Return procedure for MPXM2051GS:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPXM2051GS Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…