NXP Semiconductors MPXM2102AS

Part No.:
MPXM2102AS
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
5-SMD Module, Top Port
Datasheet:
AetrixMPXM2102AS.pdf
Description:
SENSOR 14.5PSIA 0.12" .04V 5MPAK
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:3,995

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MPXM2102AS from NXP Semiconductors (formerly Freescale) is a monolithic silicon piezoresistive absolute pressure sensor with on-chip temperature compensation, delivering a ratiometric 40 mV full-scale output at 10 V supply across 0–100 kPa range. It features ±0.6%VFSS linearity, ±0.1%VFSS pressure hysteresis, and operates from −40°C to +125°C. Used in medical diagnostics and barometric sensing where stable low-pressure measurement is required.

For engineers reviewing the MPXM2102AS datasheet, MPXM2102AS pinout, MPXM2102AS application, or MPXM2102AS equivalent, key selection criteria include its MPAK package (Case 1320A), differential/gauge-compatible port configuration, 1.0 ms response time, and compatibility with 10 VDC excitation for analog signal conditioning in embedded pressure monitoring systems.

Technical Context

The MPXM2102AS integrates a laser-trimmed silicon diaphragm with thin-film resistor networks for span and offset calibration. Its ratiometric output scales linearly with supply voltage, enabling direct interface with ADCs without external reference scaling.

On-chip temperature compensation corrects both full-scale span (TCVFSS ±2.0%VFSS) and offset (TCVOFF ±1.0 mV) over 0°C to +85°C, while maximum operating temperature extends to +125°C. The device uses dry air as specified pressure media and requires identification of the P1 (pressure) side per Case 1320A port-attached marking.

Key Specifications

Parameter Value and Actual Design Meaning
Pressure Range0–100 kPa absolute - defines full-scale input for medical barometry and altitude sensing
Full Scale Output40 mV typical at 10 V supply - enables high-resolution 12-bit+ ADC digitization with minimal gain
Linearity Error±0.6%VFSS (end-point method) - ensures <±0.6 kPa absolute error across full scale
Response Time1.0 ms (10%–90%) - supports dynamic pressure monitoring up to ~350 Hz bandwidth
Supply Voltage10 VDC nominal, 16 VDC max - compatible with standard industrial 10 V references and tolerant of rail variation
Operating Temp−40°C to +125°C - validated for under-hood automotive and industrial ambient environments
Offset Voltage−2.0 to +2.0 mV at min pressure - sets baseline for zero-pressure calibration in system firmware

Pinout & Package

MPXM2102AS is housed in the MPAK package (Case 1320A), a surface-mount, 4-pin leaded ceramic package with stainless-steel port attachment and silicone-gel-isolated die. Pin 1 is ground, Pin 2 is −VOUT, Pin 3 is VS, and Pin 4 is +VOUT - matching Style 3 pinout per Freescale documentation.

Pin/Terminal Circuit Role Design Meaning
Pin 1GNDReference ground for supply and output - must be low-impedance connection to minimize noise coupling
Pin 2−VOUTNegative output terminal - forms differential pair with Pin 4; used for noise-rejecting instrumentation amp inputs
Pin 3VSPositive supply input - supplies internal Wheatstone bridge; ratiometric output depends on stability of this rail
Pin 4+VOUTPositive output terminal - delivers voltage proportional to applied pressure relative to vacuum reference

Key Features

Feature Design Value
On-chip temperature compensationCorrects span and offset errors over 0°C to +85°C without external circuitry
Laser-trimmed calibrationEliminates need for system-level trimming; achieves ±0.6%VFSS linearity out-of-box
Ratiometric outputOutput scales with supply voltage - removes dependency on precision voltage references
Differential output architectureEnables common-mode noise rejection in noisy EMI environments via instrumentation amplifiers
MPAK package with port-attached P1 sideFacilitates PCB-level mounting with direct hose/barb connection to pressure source

Applications

Medical Diagnostics Barometric Sensing

Use Scenario: Non-invasive respiratory flow and airway pressure monitoring in portable ventilators and spirometers.

IC Role / Device Role / Timing Role: Absolute pressure transducer measuring patient airway pressure relative to sealed vacuum reference.

Use Value: Delivers ±0.1 kPa repeatability and <1 ms response - sufficient for real-time breath cycle detection and alarm triggering.

Use Scenario: Altitude estimation and weather station pressure logging in battery-powered IoT nodes.

IC Role / Device Role / Timing Role: High-stability absolute pressure sensor referenced to internal vacuum cavity.

Use Value: −40°C to +85°C compensated operation ensures <±0.5 kPa drift over environmental cycling, critical for long-term calibration stability.

Pump/Motor Control Level Detectors

Use Scenario: Closed-loop pressure feedback in HVAC blower control and industrial pump systems.

IC Role / Device Role / Timing Role: Absolute pressure monitor detecting system backpressure to modulate motor speed.

Use Value: 100 kPa full-scale range and 6 mA supply current enable direct microcontroller interfacing with minimal external components.

Use Scenario: Liquid level measurement in tanks using hydrostatic pressure of column height.

IC Role / Device Role / Timing Role: Gauge-mode pressure sensor (P1 exposed to fluid, P2 vented to atmosphere).

Use Value: Port-attached P1 side (Case 1320A) allows direct hose coupling to tank bottom port; ±0.1%VFSS hysteresis prevents false level transitions during fill/empty cycles.

Equivalent & Alternatives

The following parts are listed as comparable options for similar absolute pressure sensing applications.

Alternative Part Technical Difference Application Difference Selection Advice
MPXV7002DPSmaller SOIC-8 package; 0–25 kPa range; 2.5 V supply; I²C digital outputRequires microcontroller with I²C; unsuitable for analog-only systems or >25 kPa rangesSelect when digital interface and space constraints outweigh need for analog simplicity and extended range.
MP3V5050G50 kPa gauge range; 5 V supply; 0.5–4.5 V ratiometric output; same MPAK packageLacks absolute vacuum reference; not usable for barometric or altimeter applicationsChoose only for differential/gauge pressure tasks where vacuum reference is unnecessary and 5 V rails dominate the design.

Compared with MPXM2102AS, MPXV7002DP offers digital convenience but sacrifices analog flexibility and full-scale range, while MP3V5050G shares the MPAK form factor but lacks the absolute reference needed for atmospheric pressure measurement - making MPXM2102AS uniquely suited for calibrated barometric and medical absolute pressure use cases.

Availability

MPXM2102AS is available at Aetrix Electronics and suitable for medical diagnostics, barometric sensing, and pump/motor control requiring stable component supply, long-lifecycle assurance, and traceable sourcing for FDA-regulated or industrial safety-critical designs.

Supply support for MPXM2102AS includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

NXP Semiconductors acquired Freescale in 2015 and continues to support legacy pressure sensor families with full datasheet, reliability, and packaging documentation.

The MPX2102 series was designed for high-accuracy, temperature-stable absolute and differential pressure measurement in medical, industrial, and automotive subsystems - emphasizing monolithic integration, laser calibration, and robust packaging for harsh environments.

FAQ

What is the pressure type supported by the MPXM2102AS?

The MPXM2102AS is an absolute pressure sensor with a built-in vacuum reference cavity. It measures pressure relative to absolute zero (vacuum), not ambient atmospheric pressure. This makes MPXM2102AS appropriate for barometric sensing, altimeters, and medical devices requiring true absolute pressure values independent of local weather conditions.

What is the correct pinout configuration for MPXM2102AS?

The MPXM2102AS uses Style 3 pinout per Freescale documentation: Pin 1 = GND, Pin 2 = −VOUT, Pin 3 = VS, Pin 4 = +VOUT. This differential output configuration requires connection to an instrumentation amplifier or differential-input ADC. The P1 (pressure) side is identified by the port-attached marking on the Case 1320A package.

Can MPXM2102AS operate with a 5 V supply instead of 10 V?

MPXM2102AS is specified for 10 VDC nominal supply (range 10–16 VDC). While it may produce output at 5 V, the full-scale output drops to ~20 mV and temperature compensation performance is not guaranteed outside the validated 10 V operating point. Using 5 V violates the datasheet's excitation specification and risks increased error beyond ±1.0%VFSS.

Is MPXM2102AS compatible with wet media such as water or oil?

No. MPXM2102AS is qualified only for dry air as the pressure medium. Exposure to liquids, oils, or corrosive gases may degrade the silicone gel isolation layer and damage the silicon diaphragm. For wet media, NXP recommends evaluating purpose-built media-isolated sensors like the MP3H6115A or contacting factory application engineering for compatibility testing.

What is the warm-up time specification for MPXM2102AS?

The MPXM2102AS has a specified warm-up time of 20 ms - defined as the time required after power-on for output to settle within final value tolerance. This allows rapid system initialization in battery-powered devices. Full thermal stabilization for temperature-compensated accuracy occurs within seconds, but electrical output is stable within 20 ms for timing-critical sampling.

MPXM2102AS Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MPXM2102
Package/Case:
5-SMD Module, Top Port
Packaging:
Tube
Product Status:
Active
Applications:
Board Mount
Pressure Type:
Absolute
Operating Pressure:
14.5PSI (100kPa)
Output Type:
Wheatstone Bridge
Output:
0 mV ~ 40 mV (10V)
Accuracy:
-
Voltage - Supply:
10V ~ 16V
Port Size:
Male - 0.12" (2.97mm) Tube
Port Style:
Barbless
Features:
Temperature Compensated
Termination Style:
Gull Wing
Maximum Pressure:
58.02PSI (400kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
5-MPAK

MPXM2102AS FAQ

1.How can I place an order for MPXM2102AS through Aetrix?

Please submit a Request for Quotation (RFQ) for MPXM2102AS on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MPXM2102AS reliable?

The price and inventory of MPXM2102AS are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPXM2102AS is usually 5 days.

3.What payment methods are accepted for MPXM2102AS?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPXM2102AS transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MPXM2102AS?

MPXM2102AS orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MPXM2102AS order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MPXM2102AS?

For technical support, including MPXM2102AS datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPXM2102AS requirements.

6.How does Aetrix verify that MPXM2102AS is sourced from the original manufacturer or authorized distributors?

All MPXM2102AS products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPXM2102AS meets industry standards.

7.What is the process for return or replacement of MPXM2102AS?

All MPXM2102AS units undergo pre-shipment inspection (PSI). If there is an issue with MPXM2102AS, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MPXM2102AS part is unused and in its original packaging.

Return procedure for MPXM2102AS:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MPXM2102AS Tags

  • MPXM2102AS
  • MPXM2102AS PDF
  • MPXM2102AS Datasheet
  • MPXM2102AS Specifications
  • MPXM2102AS Images
  • NXP Semiconductors
  • NXP Semiconductors MPXM2102AS
  • Buy MPXM2102AS
  • MPXM2102AS Price
  • MPXM2102AS Distributor
  • MPXM2102AS Supplier
  • MPXM2102AS Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER