NXP Semiconductors MPXM2102AT1
- Part No.:
- MPXM2102AT1
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 5-SMD Module
- Datasheet:
-
MPXM2102AT1.pdf
- Description:
- SENSOR 14.5PSIA .04V 5MPAK
- Quantity:
- Payment:

- Shipping:

Inventory:510
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPXM2102AT1 from NXP Semiconductors (formerly Freescale) is a temperature-compensated silicon piezoresistive pressure sensor in MPAK package, providing 40 mV full-scale output at 10 V supply, ±0.6% VFSS linearity over 0–100 kPa absolute pressure range, and operating from –40°C to +125°C. It serves as a primary analog pressure transducer in medical diagnostics, barometric sensing, and industrial pump control systems.
For engineers reviewing the MPXM2102AT1 datasheet, MPXM2102AT1 pinout, MPXM2102AT1 application, or MPXM2102AT1 equivalent, key selection criteria include its ratiometric 10 V excitation requirement, on-chip temperature compensation across 0–85°C, 1 ms response time, and stainless-steel cap-based absolute pressure configuration with P1-side identification.
Technical Context
The MPXM2102AT1 integrates a monolithic silicon diaphragm with laser-trimmed piezoresistive strain gauges and thin-film resistor networks for precision span and offset calibration. Its internal circuitry includes on-chip temperature compensation circuitry that actively corrects both full-scale span drift (±2.0% VFSS/°C) and offset drift (±1.0 mV/°C) over 0–85°C.
This absolute-pressure sensor features a built-in reference vacuum cavity, delivering a decreasing output voltage under vacuum applied to the P1 side. It operates ratiometrically - output scales linearly with supply voltage - and requires no external signal conditioning beyond basic buffering due to its low-impedance differential output (ZOUT = 1400–3000 Ω).
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–100 kPa absolute; defines full-scale input range for calibrated output, compatible with 14.5 psi applications. |
| Full Scale Span | 38.5–41.5 mV at VS = 10 VDC; enables direct ADC interfacing with ≥12-bit resolution for sub-1 kPa accuracy. |
| Supply Voltage | 10 VDC typical, 16 VDC max; ratiometric operation ensures output scaling with supply, simplifying system-level calibration. |
| Linearity Error | ±0.6% VFSS (end-point method); specifies worst-case deviation from ideal linear transfer function over full pressure range. |
| Response Time | 1.0 ms (10%–90%); supports dynamic pressure monitoring in fast-cycling pneumatic systems and motor control loops. |
| Operating Temp | –40°C to +125°C ambient; validated for harsh environments including engine bay and industrial enclosures. |
| Offset Voltage | –2.0 to +2.0 mV at min pressure; sets baseline output level, critical for zero-pressure reference in altimeter/barometer designs. |
Pinout & Package
MPXM2102AT1 uses the MPAK package (Case 1320), featuring a stainless-steel cap on the P1 (pressure) side and a molded plastic body with 4-pin lead frame. The package provides environmental isolation via silicone gel encapsulation of the die and wire bonds.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Pin 1 | GND | Ground reference for supply and output; must be low-impedance connection to minimize common-mode noise in differential measurement. |
| Pin 2 | +VOUT | Positive output terminal; delivers voltage proportional to applied absolute pressure relative to internal vacuum reference. |
| Pin 3 | VS | Supply input (10 VDC typical); powers internal Wheatstone bridge and compensation circuitry; ratiometric behavior ties output scaling directly to this rail. |
| Pin 4 | –VOUT | Negative output terminal; completes differential output pair; enables rejection of common-mode supply and thermal noise. |
Key Features
| Feature | Design Value |
|---|---|
| On-chip temperature compensation | Validated over 0°C to +85°C ambient; eliminates need for external thermistor networks or digital correction in embedded systems. |
| Laser-trimmed calibration | Factory-set span and offset; achieves ±0.6% VFSS linearity without user trimming, reducing production test time. |
| Differential output architecture | Low-impedance balanced pair (ZOUT = 1400–3000 Ω); improves noise immunity and enables direct connection to instrumentation amplifiers or SAR ADCs. |
| Stainless-steel absolute pressure port | P1-side metal cap with defined port geometry; ensures long-term stability and compatibility with dry air, non-corrosive gases, and medical-grade media. |
| Ratiometric output | Output scales linearly with VS; allows use of same supply for sensor and ADC reference, removing gain error from supply variation. |
Applications
| Medical Diagnostics | Barometric Sensing |
|---|---|
Use Scenario: Non-invasive blood pressure monitoring and respiratory flow analysis in portable clinical devices. IC Role / Device Role / Timing Role: Absolute pressure transducer measuring cuff inflation pressure or airway differential vs. ambient. Use Value: 0–100 kPa range and ±0.6% VFSS linearity enable accurate systolic/diastolic detection per AAMI standards. |
Use Scenario: Altitude estimation and weather station pressure logging in battery-powered IoT nodes. IC Role / Device Role / Timing Role: Primary atmospheric pressure sensor feeding microcontroller ADC for compensated altitude calculation. Use Value: On-chip temperature compensation ensures stable 100 kPa full-scale output across –40°C to +85°C operating range without firmware correction. |
| Pump/Motor Control | Level Detection |
Use Scenario: Closed-loop pressure feedback in HVAC blower systems and industrial hydraulic pumps. IC Role / Device Role / Timing Role: Real-time absolute pressure monitor regulating motor speed via PID loop based on system backpressure. Use Value: 1 ms response time supports fast transient detection during valve switching, preventing overpressure shutdown events. |
Use Scenario: Liquid level inference in sealed tanks using hydrostatic pressure measurement. IC Role / Device Role / Timing Role: Absolute pressure interface mounted at tank base, referenced to fixed head height. Use Value: Stainless-steel P1 cap and silicone-gel isolation ensure long-term reliability in humid or condensing environments. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar absolute pressure transducer applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX5100AP | Wider 0–100 kPa range but higher 50 mV FS output; requires 5 V supply; different M12 package with dual ports. | Designed for gauge/differential configurations; lacks stainless-steel absolute cap; unsuitable for vacuum-referenced barometry. | Select MPX5100AP only when 5 V system integration and higher output SNR outweigh package and reference differences. |
| MPXV7002DP | 2.5 V supply, I²C digital output, ±1.5% accuracy; smaller SMD package; no analog differential output. | Targets low-power, digitally interfaced designs; lacks analog ratiometric output needed for legacy ADC or analog control loops. | Choose MPXV7002DP for new battery-powered designs requiring digital bus integration and minimal external components. |
Compared with MPXM2102AT1, MPX5100AP offers higher output but requires redesign for 5 V biasing and lacks absolute vacuum reference integrity, while MPXV7002DP trades analog flexibility for digital convenience and reduced accuracy - making MPXM2102AT1 optimal for analog-critical, temperature-stable absolute pressure measurement.
Availability
MPXM2102AT1 is available at Aetrix Electronics and suitable for medical diagnostics, barometric sensing, and pump/motor control applications requiring stable component supply, long-lifecycle support, and traceable sourcing for FDA-regulated or industrial safety-critical designs.
Supply support for MPXM2102AT1 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors acquired Freescale in 2015 and maintains its high-reliability sensor portfolio, focusing on automotive, industrial, and medical-grade analog ICs with stringent qualification and long-term supply commitments.
The MPXM2102AT1 belongs to the MPX2102 series of monolithic silicon pressure sensors, designed specifically for cost-sensitive yet accuracy-demanding absolute pressure measurement in non-invasive medical, environmental, and industrial control systems.
FAQ
What is the pressure type and reference configuration of the MPXM2102AT1?
The MPXM2102AT1 is an absolute pressure sensor with an internal vacuum reference cavity. Its output voltage decreases when vacuum is applied to the P1 (stainless-steel cap) side relative to ambient. This configuration makes MPXM2102AT1 suitable for barometric and altimetric applications where measurement is referenced to perfect vacuum, not ambient or another port.
Does the MPXM2102AT1 require external temperature compensation?
No, the MPXM2102AT1 includes on-chip temperature compensation circuitry validated over 0°C to +85°C. It corrects both full-scale span drift (TCVFSS = ±2.0% VFSS) and offset drift (TCVOFF = ±1.0 mV) without external components. This eliminates the need for thermistors or lookup-table firmware correction in most embedded applications using MPXM2102AT1.
What is the recommended supply voltage and current draw for MPXM2102AT1?
The MPXM2102AT1 is specified for 10 VDC typical supply (range: 10–16 VDC) and draws 6.0 mA typical supply current. Its ratiometric output means the full-scale voltage scales linearly with VS, so maintaining stable 10 V excitation ensures consistent 40 mV FS output. Operating above 16 VDC risks self-heating-induced errors and is not recommended for MPXM2102AT1.
How is the pinout oriented and how do I identify the P1 pressure side on MPXM2102AT1?
MPXM2102AT1 follows Style 1 pinout: Pin 1 = GND, Pin 2 = +VOUT, Pin 3 = VS, Pin 4 = –VOUT. The P1 (pressure) side is identified by the stainless-steel cap - confirmed in the datasheet for Case 1320 variants like MPXM2102AT1. Always mount the stainless-steel cap toward the measured pressure source when integrating MPXM2102AT1 into a system.
Can MPXM2102AT1 be used with dry air only, or is it compatible with other media?
The MPXM2102AT1's operating characteristics and reliability testing were performed using dry air. While the stainless-steel cap and silicone-gel isolation provide robustness, exposure to corrosive, condensing, or liquid media may degrade long-term performance. For non-dry-air applications, consult NXP's media compatibility documentation before deploying MPXM2102AT1 in final designs.
MPXM2102AT1 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPXM2102
- Package/Case:
- 5-SMD Module
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Absolute
- Operating Pressure:
- 14.5PSI (100kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 40 mV (10V)
- Accuracy:
- -
- Voltage - Supply:
- 10V ~ 16V
- Port Size:
- -
- Port Style:
- No Port
- Features:
- Temperature Compensated
- Termination Style:
- Gull Wing
- Maximum Pressure:
- 58.02PSI (400kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 5-MPAK
MPXM2102AT1 FAQ
1.How can I place an order for MPXM2102AT1 through Aetrix?
Please submit a Request for Quotation (RFQ) for MPXM2102AT1 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPXM2102AT1 reliable?
The price and inventory of MPXM2102AT1 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPXM2102AT1 is usually 5 days.
3.What payment methods are accepted for MPXM2102AT1?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPXM2102AT1 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPXM2102AT1?
MPXM2102AT1 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPXM2102AT1 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPXM2102AT1?
For technical support, including MPXM2102AT1 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPXM2102AT1 requirements.
6.How does Aetrix verify that MPXM2102AT1 is sourced from the original manufacturer or authorized distributors?
All MPXM2102AT1 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPXM2102AT1 meets industry standards.
7.What is the process for return or replacement of MPXM2102AT1?
All MPXM2102AT1 units undergo pre-shipment inspection (PSI). If there is an issue with MPXM2102AT1, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPXM2102AT1 part is unused and in its original packaging.
Return procedure for MPXM2102AT1:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPXM2102AT1 Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…