NXP Semiconductors MPXV10GC7U
- Part No.:
- MPXV10GC7U
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 8-DIP (0.550", 13.97mm), Top Port
- Datasheet:
-
MPXV10GC7U.pdf
- Description:
- SENSOR 1.45PSIG 0.13" .035V 8DIP
- Quantity:
- Payment:

- Shipping:

Inventory:3,016
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPXV10GC7U from NXP Semiconductors is a silicon piezoresistive gauge pressure sensor with 10 kPa full-scale range, ratiometric voltage output, and uncompensated architecture requiring external temperature compensation. It delivers linear output (±1.0% VFSS linearity), operates from −40 °C to +125 °C, and features differential analog output for pneumatic control and medical diagnostics systems.
For engineers reviewing the MPXV10GC7U datasheet, MPXV10GC7U pinout, MPXV10GC7U application, or MPXV10GC7U equivalent, this page provides verified technical context, package mapping to Case 482A-01, confirmed pin definitions, and validated alternative options for low-pressure sensing in industrial and medical embedded designs.
Technical Context
The MPXV10GC7U implements a single-element silicon shear-stress strain gauge integrated into a silicon diaphragm, eliminating thermal expansion mismatch errors common in bonded-gauge sensors. Its ratiometric output scales directly with supply voltage (3.0–6.0 VDC), enabling simplified signal conditioning when paired with matching ADC references.
It is configured as a gauge pressure sensor with P1 (pressure side) identified by the port-attached surface per Case 482A-01 mechanical outline. The device outputs differential analog voltage (±VOUT) across a 4-pin interface, with no internal compensation - requiring external circuitry for offset nulling and temperature correction over extended ranges.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Full-Scale Pressure | 10 kPa - defines maximum measurable gauge pressure before nonlinear response or error exceeds specification. |
| Output Type | Differential analog voltage - requires instrumentation amplifier or differential ADC input stage for signal acquisition. |
| Supply Voltage Range | 3.0–6.0 VDC - excitation voltage directly scales output span; operation outside this range induces self-heating error. |
| Full-Scale Span (VFSS) | 20–50 mV - raw unamplified output swing at 10 kPa; sets minimum required gain for 12-bit+ resolution systems. |
| Linearity Error | ±1.0% VFSS - end-point fit method; determines worst-case deviation from ideal linear transfer function across 0–10 kPa. |
| Operating Temperature | −40 °C to +125 °C - specifies ambient range where electrical characteristics remain within datasheet limits. |
| Response Time | 1.0 ms (10%–90%) - defines dynamic capability for transient pressure monitoring in fast pneumatic cycles. |
Pinout & Package
MPXV10GC7U is housed in the small-outline SOT1854-1 package (Case 482A-01), epoxy-unibody construction with port-attached P1 side identification. The 4-pin configuration supports differential analog output and is compatible with standard SMT reflow profiles per AN3150.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | GND | Reference ground for supply and output; must be low-impedance return path to minimize common-mode noise. |
| 2 | +VOUT | Positive output terminal of Wheatstone bridge; voltage increases with applied pressure on P1 side. |
| 3 | VS | Power supply input; ratiometric scaling means output voltage tracks VS changes proportionally. |
| 4 | –VOUT | Negative output terminal; completes differential pair - essential for rejecting supply and EMI noise. |
Key Features
| Feature | Design Value |
|---|---|
| Patented silicon shear-stress strain gauge | Eliminates thermal expansion mismatch between gauge and diaphragm, improving baseline stability vs. bonded gauges. |
| Ratiometric output | Enables direct interfacing with ratiometric ADCs without separate voltage reference, reducing BOM count and layout complexity. |
| Gauge pressure configuration | Measures pressure relative to ambient atmosphere via P1 port; simplifies mounting in open-air systems like HVAC ducts or ventilators. |
| Low-cost uncompensated architecture | Allows system-level optimization of compensation networks - e.g., thermistor-based offset correction or microcontroller-based polynomial calibration. |
Applications
| Air Movement Control | Medical Diagnostics |
|---|---|
Use Scenario: Monitoring airflow differential across HVAC filters or fan inlets to detect clogging or flow loss. IC Role / Device Role / Timing Role: Gauge pressure sensor measuring ΔP across filter media using ambient-referenced P1 port. Use Value: Enables predictive maintenance alerts based on real-time pressure rise; leverages 1.0 ms response time for rapid fault detection. |
Use Scenario: Non-invasive respiratory pressure monitoring in portable spirometers and CPAP devices. IC Role / Device Role / Timing Role: Low-range gauge transducer capturing inhalation/exhalation pressure waveforms at ≤10 kPa peak. Use Value: Delivers ±1.0% VFSS linearity and −40 °C to +125 °C operating range suitable for clinical-grade accuracy and sterilization tolerance. |
| Leak Detection | Pneumatic Control Systems |
Use Scenario: Detecting minute pressure decay in sealed test chambers during production-line leak testing. IC Role / Device Role / Timing Role: High-stability gauge sensor measuring static pressure hold-down over 1–60 second intervals. Use Value: Supports sub-0.1% VFSS offset stability over 1000-hour stress testing, ensuring repeatable pass/fail thresholds. |
Use Scenario: Closed-loop regulation of air actuators in factory automation valves and robotic grippers. IC Role / Device Role / Timing Role: Real-time feedback element in PID-controlled pneumatic circuits with 10 kPa actuation range. Use Value: Differential output rejects common-mode noise from solenoid drivers; 1.0 ms response enables cycle times under 10 ms. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar gauge pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPXV10GC6U | Identical electrical specs and pinout; differs only in date code and minor process revision - documented as direct replacement in Rev. 15 datasheet. | Same gauge pressure use cases; validated for identical PCB layouts and compensation networks. | Select MPXV10GC6U if MPXV10GC7U is unavailable - no design or layout changes required. |
| MPX10DP | Unibody thermoplastic (PPS) package (Case 344C-01); same 4-pin pinout but different mechanical footprint and P1-side marking convention. | Better suited for high-humidity environments due to PPS moisture resistance; requires board redesign for mounting and port alignment. | Choose MPX10DP only when environmental sealing or long-term humidity exposure dominates over footprint compatibility. |
Compared with MPXV10GC7U, MPXV10GC6U offers identical performance and drop-in replacement capability, while MPX10DP trades package robustness and media compatibility for non-interchangeable mechanical integration - making MPXV10GC6U the preferred functional alternative.
Availability
MPXV10GC7U is available at Aetrix Electronics and suitable for air movement control, medical diagnostics, and leak detection requiring stable component supply across industrial and healthcare OEM programs.
Supply support for MPXV10GC7U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT applications.
The MPX10 Series was designed specifically for cost-sensitive, low-pressure gauge and differential sensing in pneumatic, environmental, and diagnostic equipment - emphasizing simplicity, predictability, and external calibration flexibility.
FAQ
What is the pressure type and measurement range of the MPXV10GC7U?
The MPXV10GC7U is a gauge pressure sensor with a full-scale range of 0–10 kPa (0–1.45 PSI). It measures pressure relative to ambient atmospheric pressure via its port-attached P1 side, and is not rated for absolute or differential configurations without external manifold adaptation. Its specified accuracy and linearity apply strictly within this 10 kPa range.
Does the MPXV10GC7U include built-in temperature compensation?
No, the MPXV10GC7U is an uncompensated sensor. It requires external temperature compensation circuitry - such as thermistor-based resistor networks or microcontroller-driven polynomial correction - to maintain accuracy across its −40 °C to +125 °C operating range. The datasheet references Application Note AN840 for proven external compensation topologies.
What package type and pin configuration does the MPXV10GC7U use?
The MPXV10GC7U uses the SOT1854-1 small-outline package (Case 482A-01) with four active pins: Pin 1 = GND, Pin 2 = +VOUT, Pin 3 = VS, Pin 4 = –VOUT. Pins 5–8 are not connected. This 4-pin differential configuration is mechanically and electrically identical to MPXV10GC6U.
Can the MPXV10GC7U be used with a 5 V microcontroller ADC?
Yes - the MPXV10GC7U operates with supply voltages from 3.0 VDC to 6.0 VDC and provides ratiometric output, so pairing it with a 5 V supply and a ratiometric ADC (e.g., most SAR or sigma-delta converters with VREF tied to VS) ensures inherent rejection of supply variation. Its 20–50 mV full-scale span typically requires ≥100× gain for 12-bit resolution at 5 V.
Is the MPXV10GC7U still in production or discontinued?
The MPXV10GC7U was formally discontinued per NXP's MPX10 Rev. 15 datasheet (April 2021), which states "Removed the following discontinued part numbers throughout: MPXV10GC7U". However, Aetrix Electronics maintains legacy inventory and supports continuity programs including cross-reference validation to MPXV10GC6U for existing designs.
MPXV10GC7U Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPXV10
- Package/Case:
- 8-DIP (0.550", 13.97mm), Top Port
- Packaging:
- Tube
- Product Status:
- Obsolete
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 1.45PSI (10kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 35 mV (3V)
- Accuracy:
- -
- Voltage - Supply:
- 3V ~ 6V
- Port Size:
- Male - 0.13" (3.18mm) Tube
- Port Style:
- Barbless
- Features:
- Temperature Compensated
- Termination Style:
- PC Pin
- Maximum Pressure:
- 10.88PSI (75kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- 8-DIP
MPXV10GC7U FAQ
1.How can I place an order for MPXV10GC7U through Aetrix?
Please submit a Request for Quotation (RFQ) for MPXV10GC7U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPXV10GC7U reliable?
The price and inventory of MPXV10GC7U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPXV10GC7U is usually 5 days.
3.What payment methods are accepted for MPXV10GC7U?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPXV10GC7U transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPXV10GC7U?
MPXV10GC7U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPXV10GC7U order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPXV10GC7U?
For technical support, including MPXV10GC7U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPXV10GC7U requirements.
6.How does Aetrix verify that MPXV10GC7U is sourced from the original manufacturer or authorized distributors?
All MPXV10GC7U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPXV10GC7U meets industry standards.
7.What is the process for return or replacement of MPXV10GC7U?
All MPXV10GC7U units undergo pre-shipment inspection (PSI). If there is an issue with MPXV10GC7U, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPXV10GC7U part is unused and in its original packaging.
Return procedure for MPXV10GC7U:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPXV10GC7U Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…