NXP Semiconductors MPXV2010GP
- Part No.:
- MPXV2010GP
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 8-SMD, Gull Wing, Side Port
- Datasheet:
-
MPXV2010GP.pdf
- Description:
- SENSOR 1.45PSIG 0.13" .025V 8SOP
- Quantity:
- Payment:

- Shipping:

Inventory:1,609
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPXV2010GP from NXP Semiconductors is a gauge pressure sensor with silicon piezoresistive sensing element, delivering ratiometric voltage output proportional to applied pressure in the 0–10 kPa range. It features on-chip temperature compensation over 0 °C to 85 °C, ±1.0 %VFSS linearity, and 25 mV full-scale span at 10 V supply - used in respiratory diagnostics and air movement control systems.
For engineers reviewing the MPXV2010GP datasheet, MPXV2010GP pinout, MPXV2010GP application, or MPXV2010GP equivalent, key selection criteria include its 8-pin SOIC package (Case 1369-01), differential/gauge pressure configuration, ratiometric output behavior, and compatibility with dry clean air media under −40 °C to +125 °C operating temperature.
Technical Context
The MPXV2010GP integrates a monolithic silicon diaphragm with laser-trimmed strain gauges and thin-film resistor networks for precision calibration. Its output is ratiometric to supply voltage (VS = 10–16 Vdc), enabling direct interfacing with ADCs without external reference scaling.
It operates as a gauge sensor with P1 (pressure side) identified by the port-attached surface per Case 1369-01, and delivers analog voltage outputs (+VOUT and –VOUT) referenced to GND and VS, supporting differential readout for noise immunity in low-pressure medical and industrial sensing.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–10 kPa gauge - supports low-differential applications such as breathing circuit monitoring and HVAC airflow detection. |
| Full Scale Span | 24–26 mV at VS = 10 Vdc - enables high-resolution analog-to-digital conversion with minimal amplification. |
| Linearity Error | ±1.0 %VFSS (end-point method) - ensures predictable output deviation across full scale for calibrated measurement systems. |
| Temperature Compensation | 0 °C to 85 °C - maintains accuracy without external compensation circuitry in ambient medical or industrial enclosures. |
| Response Time | 1.0 ms (10% to 90%) - suitable for dynamic pressure events including inhalation/exhalation cycles. |
| Supply Voltage | 10–16 Vdc - compatible with standard industrial power rails and tolerant of moderate ripple. |
| Offset Voltage | ±1.0 mV at 0 kPa - simplifies zero-pressure calibration in embedded firmware or analog front-end design. |
Pinout & Package
MPXV2010GP uses an 8-pin Small Outline Integrated Circuit (SOIC) package, Case 1369-01, with 4 active terminals and 4 no-connect (n.a.) pins. The package provides mechanical stability and environmental isolation via silicone gel encapsulation over the die.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | GND | Reference ground for output and supply return - must be low-impedance to minimize common-mode error. |
| 2 | +VOUT | Positive output terminal - delivers voltage proportional to pressure relative to –VOUT; used with instrumentation amplifier inputs. |
| 3 | VS | Power supply input - supplies excitation to piezoresistive bridge; output scales ratiometrically with this voltage. |
| 4 | –VOUT | Negative output terminal - completes differential output pair; required for noise-rejecting signal acquisition. |
| 5–8 | n.a. | No internal connection - left unconnected; no electrical or thermal function in circuit layout. |
Key Features
| Feature | Design Value |
|---|---|
| Ratiometric output | Output voltage scales linearly with supply voltage - eliminates need for precision voltage references in ADC interface design. |
| On-chip temperature compensation | Calibrated over 0 °C to 85 °C - reduces system-level thermal drift compensation effort in portable or unheated enclosures. |
| Laser-trimmed span and offset | Factory-trimmed for <±1.0 mV offset and 25 mV span - enables plug-and-play integration without post-mount calibration. |
| Gauge pressure configuration | P1 side exposed via port; P2 referenced to ambient - ideal for measuring pressure relative to atmosphere in ventilators and pneumatic controls. |
| Differential analog output | +VOUT/–VOUT pair - improves common-mode noise rejection in electrically noisy environments like hospital equipment racks. |
Applications
| Respiratory Diagnostics | Air Movement Control |
|---|---|
Use Scenario: Measuring inspiratory and expiratory pressure waveforms in portable spirometers and CPAP devices. IC Role / Device Role / Timing Role: Primary gauge pressure transducer converting airway pressure into calibrated analog voltage output. Use Value: 10 kPa range and 1 ms response time capture rapid breathing dynamics; ratiometric output simplifies battery-powered ADC interfacing. | Use Scenario: Monitoring airflow in HVAC ducts and cleanroom ventilation systems to trigger fan speed adjustments. IC Role / Device Role / Timing Role: Low-range differential pressure sensor detecting static pressure drop across filters or dampers. Use Value: ±1.0 %VFSS linearity ensures accurate flow estimation over time; temperature compensation maintains calibration across seasonal ambient shifts. |
| Pressure Switching | Medical Controllers |
Use Scenario: Threshold-based activation of alarms or solenoid valves when pressure exceeds safe limits in infusion pumps or dialysis machines. IC Role / Device Role / Timing Role: Analog pressure threshold detector feeding comparator or microcontroller ADC input. Use Value: Stable 25 mV full-scale span and ±1.0 mV offset enable precise hysteresis implementation in firmware without trimming. | Use Scenario: Closed-loop pressure regulation in anesthesia delivery units requiring real-time feedback on gas mixture pressure. IC Role / Device Role / Timing Role: Feedback sensor in PID-controlled pressure loop with microcontroller-based actuator drive. Use Value: Differential output and low impedance (<3 kΩ) support robust signal integrity over PCB traces to MCU analog inputs. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar gauge pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPX2010GP | 4-pin Unibody package (Case 344B-01), same 0–10 kPa range and ratiometric output | Lower pin count, simpler PCB footprint, but lacks differential output - single-ended only | Select when board space is constrained and common-mode noise is minimal. |
| MPXV2010DP | Identical 8-pin SOIC (Case 1351-01), differential output, but differential pressure configuration (P1/P2 both ported) | Requires two pressure ports; not interchangeable in gauge-only setups where P2 is ambient | Choose only when true differential measurement (e.g., filter clog detection) is required. |
Compared with MPX2010GP, the MPXV2010GP offers differential output for noise immunity but requires more PCB area; versus MPXV2010DP, it substitutes ambient-referenced gauge operation for dual-port differential use - making MPXV2010GP optimal for atmospheric-referenced low-pressure monitoring where signal integrity matters.
Availability
MPXV2010GP is available at Aetrix Electronics and suitable for respiratory diagnostics, HVAC air movement control, and medical pressure switching requiring stable component supply and long-term lifecycle support.
Supply support for MPXV2010GP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT applications.
The MPX2010 Series was designed specifically for low-pressure, high-accuracy analog sensing in medical and industrial environments - emphasizing temperature-stable ratiometric output, factory calibration, and robust packaging for long-term reliability.
FAQ
What is the pressure type supported by the MPXV2010GP?
The MPXV2010GP is a gauge pressure sensor, meaning it measures pressure relative to ambient atmospheric pressure. Its P1 side is ported for applied pressure, while P2 is internally referenced to ambient - confirmed in Table 10 of the datasheet and Figure 6 (Case 1369-01). This configuration makes MPXV2010GP appropriate for applications like respiratory flow monitoring where absolute vacuum reference is unnecessary.
Does the MPXV2010GP require external temperature compensation?
No, the MPXV2010GP includes on-chip temperature compensation calibrated over 0 °C to 85 °C, as stated in Section 2 (Features and Benefits) and verified in Table 9 (Operating Characteristics). The device uses laser-trimmed thin-film resistors integrated on the same silicon diaphragm to minimize thermal drift - eliminating the need for external thermistors or digital compensation algorithms when operating within that range.
What is the meaning of the 'n.a.' pins (5–8) on the MPXV2010GP?
Pins 5 through 8 of the MPXV2010GP are marked 'n.a.' (not applicable) in Table 5 and have no internal connection, as shown in Figure 6. These pins serve only mechanical support and thermal dissipation roles in the Case 1369-01 package. They must remain unconnected in PCB layout - routing or soldering to them may compromise sensor performance or reliability.
Can the MPXV2010GP be used with a 5 V supply?
No, the MPXV2010GP specifies a minimum supply voltage of 10 Vdc (Table 9), with typical operation at 10 V and maximum at 16 V. Operating below 10 Vdc falls outside the validated range and risks reduced output amplitude, increased nonlinearity, and potential failure to meet datasheet specifications - including full-scale span and offset accuracy. For 5 V systems, alternative sensors such as the MPX5010 series should be evaluated.
Is the MPXV2010GP compatible with media other than air?
The MPXV2010GP is qualified for use with dry clean air, as stated in Section 9.5 and Table 8. Other media - including moisture, oils, or corrosive gases - may degrade silicone gel encapsulation or corrode internal metallization. NXP explicitly advises contacting factory support before deploying MPXV2010GP with non-air media, and referencing AN3728 for compatibility guidance.
MPXV2010GP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPXV2010
- Package/Case:
- 8-SMD, Gull Wing, Side Port
- Packaging:
- Tray
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 1.45PSI (10kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 25 mV (10V)
- Accuracy:
- ±1%
- Voltage - Supply:
- 10V ~ 16V
- Port Size:
- Male - 0.13" (3.17mm) Tube
- Port Style:
- Barbed
- Features:
- Temperature Compensated
- Termination Style:
- Gull Wing
- Maximum Pressure:
- 10.88PSI (75kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 8-SOP
MPXV2010GP FAQ
1.How can I place an order for MPXV2010GP through Aetrix?
Please submit a Request for Quotation (RFQ) for MPXV2010GP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPXV2010GP reliable?
The price and inventory of MPXV2010GP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPXV2010GP is usually 5 days.
3.What payment methods are accepted for MPXV2010GP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPXV2010GP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPXV2010GP?
MPXV2010GP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPXV2010GP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPXV2010GP?
For technical support, including MPXV2010GP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPXV2010GP requirements.
6.How does Aetrix verify that MPXV2010GP is sourced from the original manufacturer or authorized distributors?
All MPXV2010GP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPXV2010GP meets industry standards.
7.What is the process for return or replacement of MPXV2010GP?
All MPXV2010GP units undergo pre-shipment inspection (PSI). If there is an issue with MPXV2010GP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPXV2010GP part is unused and in its original packaging.
Return procedure for MPXV2010GP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPXV2010GP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…