NXP Semiconductors MPXV2053GP
- Part No.:
- MPXV2053GP
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 8-SMD, Gull Wing, Side Port
- Datasheet:
-
MPXV2053GP.pdf
- Description:
- SENSOR 7.25PSIG 0.13" .04V 8SOP
- Quantity:
- Payment:

- Shipping:

Inventory:2,158
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPXV2053GP from NXP Semiconductors is a silicon piezoresistive gauge pressure sensor with 0–50 kPa full-scale range, ratiometric voltage output (40 mV typ. span at 10 V supply), and on-chip temperature compensation over 0 °C to 85 °C. It delivers high linearity (±0.6% VFSS), low offset (±1.0 mV), and fast response (1.0 ms) for precision pressure sensing in medical diagnostics and industrial control systems.
For engineers reviewing the MPXV2053GP datasheet, MPXV2053GP pinout, MPXV2053GP application, or MPXV2053GP equivalent, this page provides verified technical context, package-specific pin definitions, real-world use scenarios, and validated alternative options for differential/gauge pressure measurement circuits requiring stable analog output and minimal external conditioning.
Technical Context
The MPXV2053GP integrates a monolithic silicon diaphragm with laser-trimmed piezoresistive strain gauges and thin-film resistor networks for precise span and offset calibration. Its ratiometric output scales linearly with supply voltage (10–16 Vdc), enabling direct interface with ADCs without separate reference voltage.
On-chip temperature compensation corrects both full-scale span (±2.0% VFSS/°C) and offset (±1.0 mV/°C) across 0–85 °C, eliminating need for external thermistors or digital correction in many embedded applications. The device operates with dry clean air as the pressure medium and features stainless-steel-reinforced gel isolation for long-term reliability.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–50 kPa gauge - supports blood pressure monitoring (≈0–375 mmHg) and low-pressure pneumatic control. |
| Full Scale Span | 40 mV typical at 10 V supply - enables 12-bit resolution with 10-bit ADC using simple gain stages. |
| Linearity Error | ±0.6% VFSS (end-point method) - ensures <±0.3 kPa absolute error across full scale at 25 °C. |
| Temperature Compensation | 0 °C to 85 °C - maintains accuracy without external thermal management in medical or robotics enclosures. |
| Response Time | 1.0 ms (10% to 90%) - suitable for dynamic pressure events like pump cycling or respiratory waveform capture. |
| Supply Voltage | 10–16 Vdc - compatible with standard industrial 12 V rails and tolerant of ripple without output degradation. |
| Output Impedance | 1400–3000 Ω - allows direct connection to instrumentation amplifiers or 10× input impedance buffers. |
Pinout & Package
MPXV2053GP uses the Small Outline Package (SOP), Case 1351-01 (SOT1693-1), an 8-pin surface-mount housing with pressure port on top and electrical connections on bottom. The package includes internal silicone gel isolation and stainless-steel cap for environmental protection.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | GND | Ground reference for output and supply return - must be low-impedance path to avoid common-mode noise. |
| 2 | +VOUT | Positive differential output terminal - connects to non-inverting input of instrumentation amplifier. |
| 3 | VS | Power supply input - decoupling capacitor (≥1 µF ceramic) required within 5 mm for stability. |
| 4 | –VOUT | Negative differential output terminal - connects to inverting input of instrumentation amplifier. |
| 5–8 | n.a. | No internal connection - electrically isolated; may be used for mechanical mounting or thermal relief. |
Key Features
| Feature | Design Value |
|---|---|
| Ratiometric output | Output scales linearly with VS (10–16 Vdc), removing need for precision voltage reference in ADC subsystems. |
| On-chip temperature compensation | Corrects both span and offset drift over 0–85 °C, reducing system-level calibration effort in medical devices. |
| Laser-trimmed calibration | Factory-set span and offset ensure ≤±1.0 mV offset and ±0.6% VFSS linearity without user trimming. |
| Differential analog output | Low-impedance push-pull configuration (+VOUT/–VOUT) rejects common-mode noise in noisy industrial environments. |
| Gauge pressure configuration | Single pressure port (P1) referenced to ambient - simplifies mechanical design vs. dual-port differential sensors. |
Applications
| Non-Invasive Blood Pressure Monitoring | Pump/Motor Controller Feedback |
|---|---|
Use Scenario: Continuous cuff-based systolic/diastolic pressure acquisition during clinical or home-care measurements. IC Role / Device Role / Timing Role: Primary analog pressure transducer converting pneumatic pressure into calibrated mV-level differential signal for microcontroller ADC sampling. Use Value: ±0.3 kPa linearity and 1 ms response enable accurate waveform reconstruction of Korotkoff sounds without oversampling. |
Use Scenario: Real-time detection of fluid flow cessation or backpressure buildup in HVAC or irrigation pumps. IC Role / Device Role / Timing Role: Closed-loop feedback element measuring outlet pressure to modulate motor speed via PWM driver. Use Value: Ratiometric output eliminates supply rail dependency, allowing stable operation across 12 V battery voltage sag (10–14 V). |
| Medical Diagnostic Equipment | Industrial Level Indicators |
Use Scenario: Airway pressure sensing in ventilators and anesthesia machines where zero-drift and repeatability are critical. IC Role / Device Role / Timing Role: High-stability gauge sensor providing analog input to safety-critical pressure alarm circuitry. Use Value: ±0.5% VFSS offset stability after 1000-hour pulsed cycling ensures alarm thresholds remain valid over equipment lifetime. |
Use Scenario: Liquid level detection in tanks using hydrostatic pressure measurement (e.g., 50 kPa ≈ 5.1 m water column). IC Role / Device Role / Timing Role: Primary transduction element converting static head pressure into scalable analog voltage for PLC analog input modules. Use Value: Stainless-steel cap and silicone gel isolation provide long-term media compatibility with water, oils, and non-corrosive fluids. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar gauge pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPXV5050GP | Higher full-scale range (0–500 kPa), same SOP package and pinout, but 5× higher sensitivity (0.2 mV/kPa vs. 0.8 mV/kPa). | Designed for industrial hydraulic monitoring, not optimized for sub-100 kPa medical waveforms. | Select when pressure range exceeds 50 kPa and system gain can accommodate lower mV/kPa output. |
| MPX5700AP | 70 kPa range, integrated signal conditioning (voltage output), 3-pin SIP package - no differential output or laser trim. | Targeted at cost-sensitive consumer appliances; lacks medical-grade linearity and temperature hysteresis specs. | Choose only for non-critical level sensing where ±2% accuracy and no calibration support are acceptable. |
Compared with MPXV2053GP, MPXV5050GP extends range but reduces resolution per kPa, while MPX5700AP sacrifices precision and differential noise rejection for integration and simplicity - neither offers drop-in replacement capability due to differing output architecture and calibration methodology.
Availability
MPXV2053GP is available at Aetrix Electronics and suitable for non-invasive blood pressure monitoring, pump/motor controller feedback, and industrial level indicators requiring stable component supply, long-term calibration retention, and medical-grade accuracy.
Supply support for MPXV2053GP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT applications.
The MPX2053 series was designed specifically for high-accuracy, low-range gauge pressure measurement in medical diagnostics and precision industrial control, emphasizing on-chip temperature compensation and factory laser calibration to minimize system-level calibration overhead.
FAQ
What is the pressure port configuration of the MPXV2053GP?
The MPXV2053GP is a gauge pressure sensor with a single pressure port (P1) on the top surface of the Small Outline Package (Case 1351-01). The P1 side is identified by the part marking on the package top, and it is referenced to ambient atmospheric pressure (P2). This configuration eliminates need for vacuum reference lines and simplifies mechanical integration in medical and industrial housings.
Does the MPXV2053GP require external temperature compensation?
No, the MPXV2053GP includes full on-chip temperature compensation for both full-scale span and offset across 0 °C to 85 °C. The device uses integrated thin-film resistors and laser-trimmed calibration to maintain ±2.0% VFSS span drift and ±1.0 mV offset drift over that range - no external thermistor, lookup table, or digital correction is required for basic operation.
Can the MPXV2053GP be used with a 3.3 V microcontroller ADC?
Yes, but not directly: the MPXV2053GP requires 10–16 Vdc supply and outputs a ratiometric differential signal centered near VS/2. To interface with a 3.3 V ADC, you must use an instrumentation amplifier (e.g., AD620 or INA128) powered from a separate 10–16 V rail, followed by level-shifting or attenuation to match the ADC's input range - the MPXV2053GP itself does not operate from 3.3 V.
What is the maximum overpressure rating for the MPXV2053GP?
The MPXV2053GP has an absolute maximum overpressure rating of 200 kPa (per Table 6), which is four times its full-scale range of 50 kPa. This provides robustness against transient pressure spikes in pump control or cuff inflation systems, though continuous operation above 50 kPa will produce nonlinear or saturated output and is not recommended for measurement integrity.
Is the MPXV2053GP compatible with aggressive media such as saline or ethanol?
No - the MPXV2053GP is qualified for use with dry clean air only. Its silicone gel isolation and stainless-steel cap are not rated for direct contact with liquids, solvents, or corrosive gases. For saline or ethanol exposure, consult NXP Application Note AN3728 and consider purpose-built media-compatible alternatives; using MPXV2053GP with such media risks long-term drift or seal failure.
MPXV2053GP Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPXV2053
- Package/Case:
- 8-SMD, Gull Wing, Side Port
- Packaging:
- Tray
- Product Status:
- Obsolete
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 7.25PSI (50kPa)
- Output Type:
- Wheatstone Bridge
- Output:
- 0 mV ~ 40 mV (10V)
- Accuracy:
- -0.6% ~ 0.4%
- Voltage - Supply:
- 10V ~ 16V
- Port Size:
- Male - 0.13" (3.17mm) Tube
- Port Style:
- Barbed
- Features:
- Temperature Compensated
- Termination Style:
- Gull Wing
- Maximum Pressure:
- 29.01PSI (200kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 8-SOP
MPXV2053GP FAQ
1.How can I place an order for MPXV2053GP through Aetrix?
Please submit a Request for Quotation (RFQ) for MPXV2053GP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPXV2053GP reliable?
The price and inventory of MPXV2053GP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPXV2053GP is usually 5 days.
3.What payment methods are accepted for MPXV2053GP?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPXV2053GP transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPXV2053GP?
MPXV2053GP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPXV2053GP order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPXV2053GP?
For technical support, including MPXV2053GP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPXV2053GP requirements.
6.How does Aetrix verify that MPXV2053GP is sourced from the original manufacturer or authorized distributors?
All MPXV2053GP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPXV2053GP meets industry standards.
7.What is the process for return or replacement of MPXV2053GP?
All MPXV2053GP units undergo pre-shipment inspection (PSI). If there is an issue with MPXV2053GP, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPXV2053GP part is unused and in its original packaging.
Return procedure for MPXV2053GP:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPXV2053GP Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…