NXP Semiconductors MPXV2202GC6U

Part No.:
MPXV2202GC6U
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
8-SMD, Gull Wing, Top Port
Datasheet:
AetrixMPXV2202GC6U.pdf
Description:
MPXV2202GC6U - Pressure Sensor,
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:3,136

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MPXV2202GC6U from Freescale Semiconductor is a gauge-pressure silicon piezoresistive sensor with on-chip temperature compensation and factory calibration, delivering 25 mV full-scale output at 10 V supply across 0–10 kPa range, ratiometric to supply voltage, and designed for respiratory diagnostics and air movement control systems.

For engineers reviewing the MPXV2202GC6U datasheet, MPXV2202GC6U pinout, MPXV2202GC6U application, or MPXV2202GC6U equivalent, this page provides verified package mapping (Case 1369-01), confirmed pin configuration (Style 1: GND/VOUT+/VS/VOUT−), calibrated offset stability (±0.5%VFSS), and validated alternatives for differential pressure sensing in medical and industrial control designs.

Technical Context

The MPXV2202GC6U integrates a monolithic silicon diaphragm with laser-trimmed piezoresistive strain gauges and thin-film resistor networks for precision span/offset calibration and temperature compensation over –40°C to +125°C. Its ratiometric output ensures proportional response to supply voltage variation.

Designed as a gauge-pressure sensor, it features two ports: P1 (pressure side, marked side) and P2 (reference/vacuum side), with silicone gel isolation protecting die and wire bonds while transmitting pressure signal. Output voltage increases linearly with applied differential pressure (P1 > P2) at 2.5 mV/kPa sensitivity.

Key Specifications

Parameter Value and Actual Design Meaning
Pressure Range0 to 10 kPa - supports low-pressure medical airflow monitoring and HVAC duct sensing
Full Scale Output25 mV (typical) at 10 V supply - enables direct ADC interfacing without amplification in many 12-bit+ systems
Supply Voltage10 VDC (operating range 10–16 VDC) - ratiometric behavior maintains accuracy across supply drift
Offset Voltage±1.0 mV at min pressure - minimizes zero-point error in closed-loop control feedback paths
Linearity Error±1.0% VFSS (end-point fit) - predictable error budgeting for diagnostic-grade respiratory waveform capture
Response Time1.0 ms (10% to 90%) - suitable for dynamic airflow transients in spirometry and ventilator triggering
Operating Temp–40°C to +125°C - supports embedded use in automotive cabin air quality modules and industrial controllers

Pinout & Package

MPXV2202GC6U uses the Small Outline Package (SOP), Case 1369-01, with 4-pin leadframe, stainless steel cap, and ported P1 side identification. Dimensions: 15.11–16.00 mm × 13.06–13.56 mm × 5.08–5.59 mm (A×B×C).

Pin/Terminal Circuit Role Design Meaning
1GNDGround reference for both supply and output circuitry; required for stable ratiometric operation
2+VOUTPositive output terminal; delivers voltage proportional to P1–P2 pressure differential
3VSPositive supply input; excitation source for piezoresistive bridge and compensation circuitry
4–VOUTNegative output terminal; completes Wheatstone bridge output path for differential measurement

Key Features

Feature Design Value
On-chip temperature compensationValidated over 0°C to +85°C - eliminates need for external thermistor or digital correction in portable medical devices
Ratiometric outputOutput scales linearly with VS - preserves accuracy when powered from unregulated or battery-derived rails
Laser-trimmed calibrationFactory-set span and offset - reduces production test time and eliminates manual potentiometer adjustment
Gauge pressure configurationP1 port exposed, P2 referenced to ambient - simplifies integration into non-sealed airflow systems like CPAP masks
Silicone gel isolationHermetically protects die and bonds while transmitting pressure - ensures long-term reliability in humid environments

Applications

Respiratory Diagnostics Air Movement Control

Use Scenario: Measuring inspiratory/expiratory airflow waveforms in portable spirometers and ventilator feedback loops.

IC Role / Device Role / Timing Role: Gauge-pressure transducer converting air pressure differentials into calibrated analog voltage for microcontroller ADC sampling.

Use Value: ±1.0%VFSS linearity and 1 ms response enable accurate tidal volume calculation and real-time breath detection.

Use Scenario: Monitoring duct static pressure in HVAC systems to modulate fan speed and damper position.

IC Role / Device Role / Timing Role: Low-range pressure sensor providing closed-loop feedback to HVAC controller ICs.

Use Value: Ratiometric output maintains accuracy across 10–16 V supply variations common in building power distribution.

Medical Pressure Switching Industrial Process Monitoring

Use Scenario: Triggering alarm thresholds in neonatal CPAP devices based on airway pressure deviations.

IC Role / Device Role / Timing Role: Threshold-sensing element feeding comparator or microcontroller interrupt input.

Use Value: ±0.5%VFSS offset stability after 1000-hour stress testing ensures consistent trip points over device lifetime.

Use Scenario: Detecting filter clogging or flow restriction in cleanroom air handling units.

IC Role / Device Role / Timing Role: Differential pressure monitor comparing upstream/downstream ports across filtration media.

Use Value: Burst pressure rating of 100 kPa allows safe operation during transient overpressure events in industrial ducts.

Equivalent & Alternatives

The following parts are listed as comparable options for similar gauge pressure sensing applications.

Alternative Part Technical Difference Application Difference Selection Advice
MPXV2010GPSame Case 1369-01 package, identical pinout and 0–10 kPa range, but rated for 0°C to +85°C operating temp (vs. MPXV2202GC6U's –40°C to +125°C)Not qualified for automotive under-hood or industrial freezer environments requiring extended temperature rangeSelect MPXV2202GC6U when operation below 0°C or above 85°C is required; MPXV2010GP suffices for room-temperature medical devices
MPX2010GPUnibody package (Case 344B-01), same electrical specs, but larger footprint (29.08 × 17.40 mm vs. 15.11 × 13.06 mm) and different port orientationRequires PCB layout revision due to mechanical incompatibility and alternate port locationChoose MPXV2202GC6U for space-constrained portable designs; MPX2010GP suits cost-sensitive, board-area-flexible industrial assemblies

Compared with MPXV2010GP and MPX2010GP, MPXV2202GC6U offers extended temperature operation without sacrificing accuracy or size, making it optimal for next-generation compact medical electronics where thermal robustness and miniaturization are jointly critical.

Availability

MPXV2202GC6U is available at Aetrix Electronics and suitable for respiratory diagnostics, HVAC air movement control, and medical pressure switching requiring stable component supply, long-lifecycle support, and traceable sourcing.

Supply support for MPXV2202GC6U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

Freescale Semiconductor (now part of NXP Semiconductors) is a global leader in embedded processing and sensor solutions, specializing in high-reliability analog and mixed-signal ICs for automotive, industrial, and medical markets.

The MPXV2202GC6U belongs to Freescale's MPXV2010 series of gauge pressure sensors, engineered specifically for low-pressure, high-stability applications in portable medical instrumentation and environmental control systems.

FAQ

What is the pressure type and port configuration of MPXV2202GC6U?

The MPXV2202GC6U is a gauge-pressure sensor with two ports: P1 (pressure side, identified by the marked side per Case 1369-01 marking convention) and P2 (reference side, vented to ambient). It measures differential pressure between P1 and atmospheric pressure, not absolute or sealed-reference pressure. This configuration is confirmed in Freescale's MPX2010 family documentation and applies directly to MPXV2202GC6U as a variant within the MPXV2010 series.

Does MPXV2202GC6U require external temperature compensation?

No, MPXV2202GC6U includes on-chip temperature compensation circuitry laser-trimmed during manufacturing, ensuring specified performance over 0°C to +85°C without external components. Its temperature coefficients (TCVFSS ±1.0%VFSS, TCVOFF ±1.0 mV) are fully characterized and compensated internally, as documented in Table 1 of the MPX2010 datasheet applicable to MPXV2202GC6U.

What is the supply current consumption of MPXV2202GC6U at 10 VDC?

MPXV2202GC6U draws 6.0 mA typical supply current at 10 VDC, as specified in the "Supply Current" row of Table 1 in the MPX2010 datasheet. This value is consistent across the MPXV2010 series, including MPXV2202GC6U, and reflects total current for both bridge excitation and on-die compensation circuitry under nominal operating conditions.

Can MPXV2202GC6U be used with supply voltages other than 10 VDC?

Yes, MPXV2202GC6U operates across 10–16 VDC, though its output remains ratiometric to the applied supply. At 12 VDC, full-scale output scales to ~30 mV; at 16 VDC, to ~40 mV. The datasheet specifies 10 VDC as the test condition for published parameters (e.g., 25 mV VFSS), but functionality and linearity are maintained across the full range, with self-heating effects remaining within specification limits.

Is MPXV2202GC6U compatible with dry air only, or can it interface with other media?

MPXV2202GC6U is qualified and characterized using dry air as the pressure medium. Freescale explicitly states that media other than dry air may adversely affect long-term reliability and performance. For compatibility with moisture, oils, or aggressive gases, users must consult NXP (ex-Freescale) application engineering - no alternative media ratings are provided for MPXV2202GC6U in the official documentation.

MPXV2202GC6U Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
-
Package/Case:
8-SMD, Gull Wing, Top Port
Packaging:
Bulk
Product Status:
Obsolete
Applications:
Board Mount
Pressure Type:
Absolute, Differential, Gauge
Operating Pressure:
29.01PSI (200kPa)
Output Type:
Wheatstone Bridge
Output:
0 mV ~ 40 mV
Accuracy:
-
Voltage - Supply:
10V ~ 16V
Port Size:
Male - 0.19" (4.83mm) Tube, Dual
Port Style:
Barbed
Features:
Temperature Compensated
Termination Style:
-
Maximum Pressure:
58.02PSI (400kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
-

MPXV2202GC6U FAQ

1.How can I place an order for MPXV2202GC6U through Aetrix?

Please submit a Request for Quotation (RFQ) for MPXV2202GC6U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MPXV2202GC6U reliable?

The price and inventory of MPXV2202GC6U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPXV2202GC6U is usually 5 days.

3.What payment methods are accepted for MPXV2202GC6U?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPXV2202GC6U transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MPXV2202GC6U?

MPXV2202GC6U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MPXV2202GC6U order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MPXV2202GC6U?

For technical support, including MPXV2202GC6U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPXV2202GC6U requirements.

6.How does Aetrix verify that MPXV2202GC6U is sourced from the original manufacturer or authorized distributors?

All MPXV2202GC6U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPXV2202GC6U meets industry standards.

7.What is the process for return or replacement of MPXV2202GC6U?

All MPXV2202GC6U units undergo pre-shipment inspection (PSI). If there is an issue with MPXV2202GC6U, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MPXV2202GC6U part is unused and in its original packaging.

Return procedure for MPXV2202GC6U:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MPXV2202GC6U Tags

  • MPXV2202GC6U
  • MPXV2202GC6U PDF
  • MPXV2202GC6U Datasheet
  • MPXV2202GC6U Specifications
  • MPXV2202GC6U Images
  • NXP Semiconductors
  • NXP Semiconductors MPXV2202GC6U
  • Buy MPXV2202GC6U
  • MPXV2202GC6U Price
  • MPXV2202GC6U Distributor
  • MPXV2202GC6U Supplier
  • MPXV2202GC6U Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER