NXP Semiconductors MPXV5004GC7U
- Part No.:
- MPXV5004GC7U
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 8-DIP (0.550", 13.97mm), Top Port
- Datasheet:
-
MPXV5004GC7U.pdf
- Description:
- SENSOR 0.57PSIG 0.13" 4.9V 8DIP
- Quantity:
- Payment:

- Shipping:

Inventory:1,344
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPXV5004GC7U from Freescale Semiconductor is a monolithic silicon piezoresistive gauge pressure sensor with 0–3.92 kPa (0–400 mm H₂O) full-scale range, ratiometric 0.2 V/kPa sensitivity, ±2.5% VFSS accuracy with autozero over 10 °C to 60 °C, and 5 VDC supply operation - designed for liquid level sensing in appliance and medical respiratory systems.
For engineers reviewing the MPXV5004GC7U datasheet, MPXV5004GC7U pinout, MPXV5004GC7U application, or MPXV5004GC7U equivalent, key selection criteria include its through-hole SOP-8 package, factory autozero capability, thermoplastic PPS housing, fluorosilicone gel isolation, and compatibility with microcontroller A/D inputs requiring low-drift analog pressure feedback.
Technical Context
The MPXV5004GC7U integrates a shear-stress strain gauge, on-chip temperature compensation circuitry, and signal conditioning onto a single die. Its output voltage follows VOUT = VS × [(0.2 × P) + 0.2] ±2.5% VFSS, where P is pressure in kPa and VS is supply voltage (4.75–5.25 VDC).
It operates across 0 °C to +85 °C ambient, with offset voltage of 0.75–1.25 V at zero pressure and full-scale span of 3.92 V at 3.92 kPa. The device uses dry air as specified pressure media and requires mechanical autozero calibration to maintain ±2.5% accuracy under thermal cycling.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–3.92 kPa (0–400 mm H₂O) gauge - defines maximum measurable differential pressure before saturation. |
| Supply Voltage | 4.75–5.25 VDC - ratiometric operation ensures output scaling tracks supply variation. |
| Output Span | 3.92 V at 3.92 kPa - enables direct interface to 5 V ADC without external amplification. |
| Accuracy | ±2.5% VFSS with autozero (10–60 °C) - requires system-level zero-point calibration during startup. |
| Offset Voltage | 0.75–1.25 V at 0 kPa - establishes baseline output for A/D conversion reference. |
| Operating Temp | 0–85 °C ambient - supports deployment in washing machines and portable respiratory devices. |
| Max Pressure | 16 kPa burst rating - provides safety margin against transient overpressure events. |
Pinout & Package
MPXV5004GC7U uses a through-hole small outline package (Case 98ASB17759C), 10.54 × 10.79 × 13.21 mm, molded in durable thermoplastic PPS with stainless steel cap and fluorosilicone gel isolation.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | DNC | Internal connection - must remain unconnected per datasheet; notch identifies this pin. |
| 2 | VS | Positive supply input - accepts 4.75–5.25 VDC; decoupling with 1.0 μF + 0.01 μF recommended. |
| 3 | GND | Analog ground reference - must be tied to system ground with low-impedance path. |
| 4 | VOUT | Analog output - delivers ratiometric voltage proportional to applied pressure (0.75–4.0 V). |
| 5–8 | DNC | Internal connections - no external connection permitted; floating pins reduce EMI susceptibility. |
Key Features
| Feature | Design Value |
|---|---|
| On-chip temperature compensation | Enables ±2.5% VFSS accuracy over 10–60 °C without external circuitry or software correction. |
| Ratiometric output transfer function | VOUT = VS × [(0.2 × P) + 0.2] - eliminates supply voltage drift impact on measurement linearity. |
| Fluorosilicone gel isolation | Protects die and wire bonds from moisture and contaminants while transmitting pressure signal reliably. |
| Thermoplastic PPS package | Provides mechanical robustness and chemical resistance suitable for humid appliance environments. |
| Autozero-compatible architecture | Supports system-level zero calibration to cancel mounting stress and thermal offset drift effects. |
Applications
| Washing Machine Water Level | Respiratory Equipment Monitoring |
|---|---|
Use Scenario: Detecting water column height in drum-based washing machines via pressure transduction at base inlet. IC Role / Device Role / Timing Role: Gauge pressure sensor measuring static head pressure of water column relative to atmospheric reference. Use Value: Enables precise fill-level control using 0–3.92 kPa range matched to typical 40 cm max water height. | Use Scenario: Monitoring airway pressure in portable CPAP or ventilator circuits during patient inhalation/exhalation cycles. IC Role / Device Role / Timing Role: Low-range gauge pressure transducer providing real-time analog feedback to closed-loop pressure control algorithm. Use Value: Delivers ±2.5% accuracy with autozero to support FDA-critical pressure regulation within 1–3 kPa therapeutic range. |
| Appliance Liquid Level Sensing | Microcontroller-Based Pressure Systems |
Use Scenario: Measuring detergent tank or softener reservoir fill level in smart home appliances using hydrostatic pressure. IC Role / Device Role / Timing Role: Analog front-end pressure interface converting fluid height into voltage for MCU A/D sampling. Use Value: Eliminates need for external signal conditioning due to built-in gain, offset, and temperature compensation. | Use Scenario: Integrating into embedded systems where microcontrollers lack dedicated pressure interfaces but have 10-bit+ ADC inputs. IC Role / Device Role / Timing Role: Self-contained analog pressure transducer with ratiometric output synchronized to MCU supply rail. Use Value: Reduces BOM count by removing op-amps, references, and calibration EEPROM in cost-sensitive designs. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar gauge pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPXV5004GP | Same 0–3.92 kPa range and accuracy, but uses surface-mount SOP-8 (Case 98ASA99303D) instead of through-hole. | Requires reflow-compatible PCB layout; unsuitable for hand-soldered prototyping or high-vibration fixtures. | Select MPXV5004GP only when automated SMT assembly is available and board space is constrained. |
| MPVZ5004GW7U | Media-resistant variant with vertical port and stainless steel cap; same electrical specs but rated for aggressive fluids. | Valid for non-dry-air media (e.g., saline, cleaning solutions); not required for standard air/water applications. | Choose MPVZ5004GW7U only if exposure to condensate, aerosols, or mild chemicals is expected in end-use environment. |
Compared with MPXV5004GC7U, MPXV5004GP offers identical performance in a surface-mount footprint ideal for volume production, while MPVZ5004GW7U adds media resistance at no electrical trade-off - both require validation of mechanical mounting and autozero implementation to match MPXV5004GC7U's ±2.5% accuracy target.
Availability
MPXV5004GC7U is available at Aetrix Electronics and suitable for washing machine water level control, respiratory equipment monitoring, and appliance liquid level sensing requiring stable component supply across industrial and medical OEM programs.
Supply support for MPXV5004GC7U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Freescale Semiconductor (now part of NXP Semiconductors) is a fabless semiconductor company specializing in embedded processing, sensors, and analog mixed-signal ICs for automotive, industrial, and consumer applications.
The MPXV5004 series belongs to Freescale's integrated pressure sensor product line, engineered specifically for cost-effective, high-accuracy analog pressure measurement in microcontroller-based systems with minimal external components.
FAQ
What is the pressure range and output behavior of the MPXV5004GC7U?
The MPXV5004GC7U has a gauge pressure range of 0–3.92 kPa (0–400 mm H₂O). Its output voltage follows VOUT = VS × [(0.2 × P) + 0.2], producing 0.75–4.0 V over full scale at 5 V supply. At zero pressure, MPXV5004GC7U outputs 0.75–1.25 V; at 3.92 kPa, it delivers up to 3.92 V. This ratiometric behavior ensures consistent scaling even with supply variation.
Does the MPXV5004GC7U require external calibration or autozero circuitry?
The MPXV5004GC7U supports autozero functionality but does not include on-board storage - system-level autozero must be implemented externally. During initialization, the host MCU reads the MPXV5004GC7U output at known zero pressure and subtracts that value from subsequent readings. This compensates for mounting stress and thermal offset drift, enabling the specified ±2.5% VFSS accuracy over 10–60 °C.
What package type and mounting method does the MPXV5004GC7U use?
The MPXV5004GC7U uses a through-hole small outline package (Case 98ASB17759C), measuring 10.54 × 10.79 × 13.21 mm. It features eight leads with pins 1 and 5–8 designated DNC (do not connect), pin 2 as VS, pin 3 as GND, and pin 4 as VOUT. The package is designed for wave soldering or manual through-hole assembly, not surface mount.
Can the MPXV5004GC7U be used with pressure media other than dry air?
The MPXV5004GC7U is characterized and qualified for dry air as the pressure medium. Use with other media - including water vapor, cleaning agents, or saline - may degrade long-term reliability or cause drift. While fluorosilicone gel provides some environmental protection, Freescale explicitly states that non-dry-air media require factory consultation. For such applications, consider the MPVZ5004GW7U variant instead of the MPXV5004GC7U.
What is the maximum operating temperature and storage limit for the MPXV5004GC7U?
The MPXV5004GC7U has an operating temperature range of 0 °C to +85 °C ambient, with temperature-compensated accuracy specified from +10 °C to +60 °C. Its storage temperature range is –30 °C to +100 °C. Exceeding +85 °C during operation risks permanent degradation of the piezoresistive element and internal compensation circuitry, and is outside the validated specification for the MPXV5004GC7U.
MPXV5004GC7U Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPXV5004
- Package/Case:
- 8-DIP (0.550", 13.97mm), Top Port
- Packaging:
- Tube
- Product Status:
- Obsolete
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 0.57PSI (3.92kPa)
- Output Type:
- Analog Voltage
- Output:
- 1 V ~ 4.9 V
- Accuracy:
- -
- Voltage - Supply:
- 4.75V ~ 5.25V
- Port Size:
- Male - 0.13" (3.17mm) Tube
- Port Style:
- Barbless
- Features:
- Temperature Compensated
- Termination Style:
- PC Pin
- Maximum Pressure:
- 2.32PSI (16kPa)
- Operating Temperature:
- 0°C ~ 85°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- 8-DIP
MPXV5004GC7U FAQ
1.How can I place an order for MPXV5004GC7U through Aetrix?
Please submit a Request for Quotation (RFQ) for MPXV5004GC7U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPXV5004GC7U reliable?
The price and inventory of MPXV5004GC7U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPXV5004GC7U is usually 5 days.
3.What payment methods are accepted for MPXV5004GC7U?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPXV5004GC7U transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPXV5004GC7U?
MPXV5004GC7U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPXV5004GC7U order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPXV5004GC7U?
For technical support, including MPXV5004GC7U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPXV5004GC7U requirements.
6.How does Aetrix verify that MPXV5004GC7U is sourced from the original manufacturer or authorized distributors?
All MPXV5004GC7U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPXV5004GC7U meets industry standards.
7.What is the process for return or replacement of MPXV5004GC7U?
All MPXV5004GC7U units undergo pre-shipment inspection (PSI). If there is an issue with MPXV5004GC7U, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPXV5004GC7U part is unused and in its original packaging.
Return procedure for MPXV5004GC7U:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPXV5004GC7U Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…