NXP Semiconductors MPXV5010GC6U

Part No.:
MPXV5010GC6U
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
8-SMD, Gull Wing, Top Port
Datasheet:
AetrixMPXV5010GC6U.pdf
Description:
SENSOR 1.45PSIG 0.13" 4.7V
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:2,253

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MPXV5010GC6U from NXP Semiconductors is a gauge pressure sensor with on-chip signal conditioning, temperature compensation, and factory calibration. It delivers a ratiometric analog output (0.2–4.925 V) over 0–10 kPa full-scale range at 5 V supply, features ±5.0% accuracy across 0° to 85°C, and uses a patented silicon shear-stress strain gauge for stable performance in HVAC and respiratory systems.

For engineers reviewing the MPXV5010GC6U datasheet, MPXV5010GC6U pinout, MPXV5010GC6U application, or MPXV5010GC6U equivalent, this page provides verified package mapping (SOT1854-1), confirmed pin functions (VS, GND, VOUT), real-world error bands (±0.5 kPa max pressure error), and two validated alternative parts for gauge-pressure sensing in microcontroller-based embedded systems.

Technical Context

The MPXV5010GC6U integrates a monolithic silicon piezoresistive sensing element with thin-film temperature compensation circuitry and dual-stage gain amplification - all on a single die. Its transfer function is defined as Vout = VS × (0.09 × P + 0.04) ± 5.0% VFSS, where P is pressure in kPa and VS is supply voltage.

It operates exclusively in gauge configuration with a single pressure port (P1 side identified by attached port per Case 482A), requires no external calibration, and relies on fluorosilicone gel isolation to protect the die while transmitting pressure signals. The device is qualified for use with dry air only; media compatibility must be confirmed separately.

Key Specifications

Parameter Value and Actual Design Meaning
Pressure Range 0–10 kPa full-scale gauge pressure - supports low-range liquid level and airflow monitoring in appliances and medical devices.
Output Voltage Range 0.2–4.925 V at VS = 5.0 V - ratiometric output enables direct A/D interfacing without external reference scaling.
Accuracy ±5.0% of full-scale span (VFSS) over 0° to 85°C - includes linearity, temperature hysteresis, pressure hysteresis, TcSpan, and TcOffset contributions.
Supply Voltage 4.75–5.25 Vdc - tightly regulated 5 V rail required; decoupling (1.0 µF + 0.01 µF + 470 pF) mandatory per Figure 11.
Response Time 1.0 ms (10% to 90%) - suitable for dynamic pressure tracking in respiratory waveform capture and process control loops.
Operating Temperature –40° to +125°C - wide ambient range allows deployment in industrial enclosures and automotive cabin environments.
Package SOT1854-1 (Case 482A) - surface-mount plastic small-outline package, 8-terminal, 2.54 mm pitch, 10.67 × 10.67 × 12.96 mm body.

Pinout & Package

SOT1854-1 package: thermoplastic (PPS) surface-mount housing with fluorosilicone gel-isolated die, axial port on P1 side (identified by attached port per Table 7), and 8-pin layout optimized for reflow soldering (Figure 29).

Pin/Terminal Circuit Role Design Meaning
1 No connect Internally unconnected; must remain floating - no PCB trace or pad connection permitted.
2 VS 5 V supply input - requires local decoupling per Figure 11; not internally current-limited.
3 GND Analog ground reference - must tie directly to system AGND plane with low-inductance path.
4 VOUT Analog output (0.2–4.925 V) - drives ≤10 kΩ load; output filtering recommended before A/D sampling.
5–8 No connect All four pins are internally unconnected - must be left open; no routing or thermal relief required.

Key Features

Feature Design Value
On-chip signal conditioning Integrated amplifier and offset/gain stage eliminate need for external op-amps or trimming resistors in basic implementations.
Temperature compensation Factory-trimmed thin-film network achieves ±5.0% VFSS accuracy over 0°–85°C without software correction.
Gauge pressure configuration Single-port design referenced to ambient pressure - simplifies mechanical mounting and eliminates differential hose routing.
Patented silicon shear-stress strain gauge Monolithic diaphragm structure minimizes hysteresis and long-term drift versus traditional piezoresistive elements.
Durable SMT packaging Epoxy-unibody construction with PPS thermoplastic case withstands vibration, thermal cycling, and humidity in industrial environments.

Applications

Hospital Beds HVAC Systems

Use Scenario: Real-time patient weight and position monitoring via mattress-integrated pressure zones.

IC Role / Device Role / Timing Role: Gauge pressure transducer measuring static air pressure in sealed bladders beneath the mattress surface.

Use Value: Enables low-power, high-reliability detection of patient movement and occupancy without moving parts or external calibration.

Use Scenario: Air duct static pressure feedback for variable-air-volume (VAV) box damper control.

IC Role / Device Role / Timing Role: Analog pressure sensor providing closed-loop input to HVAC controller's PID algorithm.

Use Value: Maintains precise airflow delivery using 1 ms response time and ±0.5 kPa pressure error band within 0–10 kPa range.

Respiratory Systems Washing Machine Water Level

Use Scenario: Exhalation/inhalation pressure waveform capture in portable CPAP and ventilator devices.

IC Role / Device Role / Timing Role: Low-noise, temperature-compensated gauge sensor interfaced to 12-bit ADC in microcontroller.

Use Value: Delivers clinically relevant pressure resolution (0.1 kPa steps) with ±5.0% VFSS accuracy across operating temperature range.

Use Scenario: Water level estimation in top-loading washing machines via air-pressure chamber coupling.

IC Role / Device Role / Timing Role: Factory-calibrated transducer converting water column height into analog voltage for MCU interpretation.

Use Value: Eliminates float switches and mechanical linkages; supports accurate fill-level detection using Reference AN1950 methodology.

Equivalent & Alternatives

The following parts are listed as comparable options for similar gauge pressure sensing applications.

Alternative Part Technical Difference Application Difference Selection Advice
MPXV5010GC7U Same SOT1854-1 package, identical electrical specs, but Case 482C marking and alternate port orientation per Table 7. Identical use cases; differs only in mechanical port alignment - requires board layout verification if replacing MPXV5010GC6U. Select when mechanical integration requires vertical port placement per Figure 6; electrically interchangeable with no firmware change.
MPXV5010GP SOT1693-3 package (12.06 × 12.06 × 7.62 mm), same 0–10 kPa range and ±5.0% accuracy, but larger footprint and different pin 1 location. Better suited for prototyping or through-hole-compatible layouts; less space-constrained than SOT1854-1. Choose for manual assembly or legacy board compatibility; requires PCB redesign due to different package outline and pinout.

Compared with MPXV5010GC6U, MPXV5010GC7U offers identical performance in a mechanically distinct variant requiring port alignment validation, while MPXV5010GP provides the same sensing capability in a larger, more accessible SMT package that eases hand-soldering but increases board area usage.

Availability

MPXV5010GC6U is available at Aetrix Electronics and suitable for HVAC control, respiratory therapy equipment, and appliance liquid level measurement requiring stable component supply across production lifecycles.

Supply support for MPXV5010GC6U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT markets.

The MPXV5010GC6U belongs to NXP's MPxx5010 series of integrated silicon pressure sensors, designed specifically for microcontroller-based systems needing calibrated, temperature-compensated analog pressure outputs without external signal conditioning.

FAQ

What is the maximum rated pressure for MPXV5010GC6U?

The MPXV5010GC6U has a maximum pressure rating of 40 kPa (Table 5). However, its specified full-scale operating range is limited to 0–10 kPa gauge pressure. Operation beyond 10 kPa may cause output saturation or nonlinearity, though the device remains undamaged up to 40 kPa per absolute limiting values.

Does MPXV5010GC6U require external calibration?

No, MPXV5010GC6U does not require external calibration. It is factory-calibrated and temperature-compensated, delivering a ratiometric analog output (Vout = VS × (0.09 × P + 0.04)) with ±5.0% VFSS accuracy over 0° to 85°C. No trimming or software correction is needed for baseline operation.

What is the correct power supply decoupling for MPXV5010GC6U?

The MPXV5010GC6U requires the decoupling network shown in Figure 11: 1.0 µF (bulk), 0.01 µF (mid-frequency), and 470 pF (high-frequency) capacitors between VS and GND, placed as close as possible to pins 2 and 3. Omitting this network violates recommended operating conditions and degrades accuracy and noise performance.

Can MPXV5010GC6U be used with media other than dry air?

No - MPXV5010GC6U qualification and reliability testing were performed exclusively with dry air as the pressure medium. Use with other gases or liquids may degrade long-term stability or damage the fluorosilicone gel isolation. Media compatibility must be confirmed directly with NXP before deployment in non-dry-air applications.

How is the pressure port oriented on MPXV5010GC6U?

Per Table 7, the MPXV5010GC6U (Case 482A) identifies its Pressure (P1) side by the attached port. This side contains the fluorosilicone gel and must face the measured pressure source. The vacuum (P2) side is ambient-exposed and must remain unobstructed for proper gauge reference.

MPXV5010GC6U Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MPXV5010
Package/Case:
8-SMD, Gull Wing, Top Port
Packaging:
Tube
Product Status:
Obsolete
Applications:
Board Mount
Pressure Type:
Vented Gauge
Operating Pressure:
1.45PSI (10kPa)
Output Type:
Analog Voltage
Output:
0.2 V ~ 4.7 V
Accuracy:
±5%
Voltage - Supply:
4.75V ~ 5.25V
Port Size:
Male - 0.13" (3.17mm) Tube
Port Style:
Barbless
Features:
Temperature Compensated
Termination Style:
Gull Wing
Maximum Pressure:
5.8PSI (40kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
-

MPXV5010GC6U FAQ

1.How can I place an order for MPXV5010GC6U through Aetrix?

Please submit a Request for Quotation (RFQ) for MPXV5010GC6U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MPXV5010GC6U reliable?

The price and inventory of MPXV5010GC6U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPXV5010GC6U is usually 5 days.

3.What payment methods are accepted for MPXV5010GC6U?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPXV5010GC6U transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MPXV5010GC6U?

MPXV5010GC6U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MPXV5010GC6U order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MPXV5010GC6U?

For technical support, including MPXV5010GC6U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPXV5010GC6U requirements.

6.How does Aetrix verify that MPXV5010GC6U is sourced from the original manufacturer or authorized distributors?

All MPXV5010GC6U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPXV5010GC6U meets industry standards.

7.What is the process for return or replacement of MPXV5010GC6U?

All MPXV5010GC6U units undergo pre-shipment inspection (PSI). If there is an issue with MPXV5010GC6U, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MPXV5010GC6U part is unused and in its original packaging.

Return procedure for MPXV5010GC6U:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MPXV5010GC6U Tags

  • MPXV5010GC6U
  • MPXV5010GC6U PDF
  • MPXV5010GC6U Datasheet
  • MPXV5010GC6U Specifications
  • MPXV5010GC6U Images
  • NXP Semiconductors
  • NXP Semiconductors MPXV5010GC6U
  • Buy MPXV5010GC6U
  • MPXV5010GC6U Price
  • MPXV5010GC6U Distributor
  • MPXV5010GC6U Supplier
  • MPXV5010GC6U Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER