NXP Semiconductors MPXV5100GC6U
- Part No.:
- MPXV5100GC6U
- Manufacturer:
- NXP Semiconductors
- Category:
- Pressure Sensors, Transducers
- Package:
- 8-SMD, Gull Wing, Top Port
- Datasheet:
-
MPXV5100GC6U.pdf
- Description:
- SENSOR 14.5PSIG 0.13" 4.7V
- Quantity:
- Payment:

- Shipping:

Inventory:1,319
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
MPXV5100GC6U from NXP Semiconductors is a gauge pressure sensor with 0–100 kPa full-scale range, ratiometric analog output (4.5–4.8 V at 5 V supply), ±2.5% accuracy over 0–85 °C, and 1 ms response time. It integrates on-chip temperature compensation and is designed for direct interface to microcontroller A/D inputs in industrial and medical pressure monitoring systems.
For engineers reviewing the MPXV5100GC6U datasheet, MPXV5100GC6U pinout, MPXV5100GC6U application, or MPXV5100GC6U equivalent, this page delivers verified specifications, small-outline package layout guidance, real-world use cases in pump control and patient monitoring, and two validated alternative parts with documented functional and packaging differences.
Technical Context
The MPXV5100GC6U uses a monolithic silicon piezoresistive sensing element with thin-film metallization and bipolar processing. Its signal path includes two gain stages and on-chip temperature compensation circuitry that corrects both offset and span drift across 0–85 °C.
It operates ratiometrically with a 4.75–5.25 V supply, delivering a linear output voltage defined by VOUT = VS × (0.009 × P + 0.04), where P is pressure in kPa. The device features fluorosilicone gel isolation of the die and stainless steel metal cover for environmental protection.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Pressure Range | 0–100 kPa gauge - supports standard atmospheric differential measurement up to ~14.5 psi. |
| Output Voltage | 0.088–0.313 V at 0 kPa; 4.587–4.813 V at 100 kPa (VS = 5.0 V) - enables direct ADC interfacing without amplification. |
| Accuracy | ±2.5% of full-scale span (VFSS) over 0–85 °C - includes linearity, temperature hysteresis, pressure hysteresis, TcSpan, and TcOffset contributions. |
| Response Time | 1.0 ms (10% to 90% step response) - suitable for dynamic pressure events in motor control and fluid system feedback loops. |
| Supply Voltage | 4.75–5.25 V DC - ratiometric operation ensures output scaling tracks supply variations, simplifying power rail design. |
| Operating Temp | −40 to +125 °C ambient - rated for harsh industrial environments including white goods and engine bay proximity. |
| Sensitivity | 45 mV/kPa - provides high-resolution analog output for sub-kPa pressure resolution with 12-bit ADCs. |
Pinout & Package
MPXV5100GC6U uses an 8-lead small outline package (case 98ASB17757C), surface-mountable with side-port configuration. The pressure port is located on the side with the part marking; the P1 (pressure) side is identified by the port attachment per NXP's identification table.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| 1 | DNC | Internal connection - must remain unconnected to avoid performance degradation or damage. |
| 2 | VS | Positive supply input - requires local 0.01 μF + 1.0 μF decoupling per NXP recommended circuit. |
| 3 | GND | Analog ground reference - must be tied to clean system ground plane with low-impedance path. |
| 4 | VOUT | Analog output - delivers ratiometric voltage proportional to applied gauge pressure; drives 0.1 mA load. |
| 5–8 | DNC | Internal connections - no external connection permitted; floating or grounded pins violate specification. |
Key Features
| Feature | Design Value |
|---|---|
| Piezoresistive silicon sensing element | Monolithic construction with micromachined diaphragm ensures long-term stability and repeatability in cyclic pressure applications. |
| On-chip temperature compensation | Corrects both offset and full-scale span drift across 0–85 °C, eliminating need for external calibration circuitry. |
| Ratiometric output | Output scales linearly with supply voltage, enabling robust operation with non-regulated or noisy 5 V rails common in embedded systems. |
| Fluorosilicone gel isolation | Protects wire bonds and die surface from moisture and chemical exposure while transmitting pressure accurately. |
| Stainless steel metal cover | Provides mechanical ruggedness and EMI shielding in industrial enclosures and medical housings. |
Applications
| Medical Patient Monitoring | Industrial Pump Control |
|---|---|
|
Use Scenario: Continuous non-invasive blood pressure or respiratory airflow monitoring in portable clinical devices. IC Role / Device Role / Timing Role: Gauge pressure transducer measuring differential airway pressure relative to atmosphere. Use Value: ±2.5% VFSS accuracy and 1 ms response enable reliable detection of breath cycles and systolic/diastolic transitions. |
Use Scenario: Closed-loop feedback for centrifugal or diaphragm pump speed regulation in HVAC or water treatment systems. IC Role / Device Role / Timing Role: Primary pressure feedback element in PID-controlled fluid delivery circuits. Use Value: Ratiometric output and −40 to +125 °C operating range support stable operation across wide ambient and fluid temperature swings. |
| White Goods Pressure Sensing | Process Control Switching |
|
Use Scenario: Water level and flow verification in washing machines and dishwashers using pressure-based tank fill detection. IC Role / Device Role / Timing Role: Low-cost, integrated gauge sensor replacing mechanical switches and analog pressure switches. Use Value: 0–100 kPa range covers typical 0–10 m water column requirements; epoxy unibody construction resists detergent exposure. |
Use Scenario: High-reliability pressure threshold detection in pneumatic actuators and compressed air lines. IC Role / Device Role / Timing Role: Analog trigger for programmable logic controllers (PLCs) or microcontrollers implementing pressure interlocks. Use Value: 45 mV/kPa sensitivity allows precise setpoint definition with 12-bit ADCs; ±0.5% VFSS offset stability ensures consistent trip points over 1000-hour life testing. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar gauge pressure sensing applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| MPXV5050GP | 50 kPa full-scale range, same 8-lead SO package, identical pinout and ratiometric transfer function. | Lower pressure range limits use to sub-atmospheric or low-differential applications (e.g., vacuum leak detection). | Select when system max pressure is ≤50 kPa and higher resolution per kPa is required. |
| MPX5100GP | Same 0–100 kPa range but in 6-lead unibody package (98ASB42796B); different footprint and port orientation. | Unibody construction offers higher media compatibility but requires larger PCB area and through-hole or specialized SMT reflow. | Choose for legacy designs using unibody layout or where fluorosilicone gel + epoxy encapsulation is preferred over small-outline metal cover. |
Compared with MPXV5100GC6U, MPXV5050GP trades full-scale range for improved resolution below 50 kPa, while MPX5100GP maintains identical pressure specs but demands different board layout and thermal management due to its unibody thermal mass and mounting method.
Availability
MPXV5100GC6U is available at Aetrix Electronics and suitable for industrial pump control, medical patient monitoring, and white goods pressure sensing requiring stable component supply, long-lifecycle assurance, and traceable sourcing.
Supply support for MPXV5100GC6U includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT applications.
The MPXV5100GC6U belongs to NXP's MPXV5100 series of integrated silicon pressure sensors, engineered specifically for cost-sensitive, high-volume embedded systems requiring calibrated analog output without external signal conditioning.
FAQ
What is the pressure port configuration of the MPXV5100GC6U?
The MPXV5100GC6U uses a side-port configuration in its 8-lead small outline package (case 98ASB17757C). The pressure port is located on the side with the part marking, designated as the P1 (pressure) side per NXP's identification table. This orientation allows direct mounting against gasketed surfaces or flexible tubing interfaces without requiring top-access ports.
Does the MPXV5100GC6U require external calibration?
No, the MPXV5100GC6U does not require external calibration. It integrates on-chip temperature compensation for both offset and full-scale span across 0–85 °C, and is factory-calibrated to deliver ±2.5% VFSS accuracy over that range. The ratiometric output (VOUT = VS × (0.009 × P + 0.04)) eliminates the need for precision voltage references in most microcontroller-based implementations.
Can the MPXV5100GC6U be used with a 3.3 V supply?
No, the MPXV5100GC6U is specified only for 4.75–5.25 V DC supply. Operation outside this range violates maximum ratings and invalidates accuracy, output voltage, and reliability specifications. For 3.3 V systems, consider NXP's MPX5050 series or other 3.3 V-compatible pressure sensors - the MPXV5100GC6U must be powered from a dedicated 5 V rail.
What is the meaning of "DNC" pins on the MPXV5100GC6U?
"DNC" stands for "Do Not Connect." Pins 1 and 5–8 on the MPXV5100GC6U are internal device connections with no external functionality. Connecting them to ground, supply, or any signal trace will degrade performance or cause permanent damage. These pins must remain electrically floating and unattached in all PCB layouts and assembly processes.
Is the MPXV5100GC6U compatible with wet media such as water or saline?
The MPXV5100GC6U is qualified for use with dry air as the pressure medium. While its fluorosilicone gel and stainless steel cover provide environmental protection, NXP explicitly states that media other than dry air may adversely affect long-term reliability and performance. For water or saline contact, consult NXP's media compatibility documentation or select a sensor qualified for liquid media - the MPXV5100GC6U is not rated for direct wet-side exposure.
MPXV5100GC6U Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- MPXV5100
- Package/Case:
- 8-SMD, Gull Wing, Top Port
- Packaging:
- Tube
- Product Status:
- Active
- Applications:
- Board Mount
- Pressure Type:
- Vented Gauge
- Operating Pressure:
- 14.5PSI (100kPa)
- Output Type:
- Analog Voltage
- Output:
- 0.2 V ~ 4.7 V
- Accuracy:
- ±2.5%
- Voltage - Supply:
- 4.75V ~ 5.25V
- Port Size:
- Male - 0.13" (3.17mm) Tube
- Port Style:
- Barbless
- Features:
- Temperature Compensated
- Termination Style:
- Gull Wing
- Maximum Pressure:
- 58.02PSI (400kPa)
- Operating Temperature:
- -40°C ~ 125°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- -
MPXV5100GC6U FAQ
1.How can I place an order for MPXV5100GC6U through Aetrix?
Please submit a Request for Quotation (RFQ) for MPXV5100GC6U on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for MPXV5100GC6U reliable?
The price and inventory of MPXV5100GC6U are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPXV5100GC6U is usually 5 days.
3.What payment methods are accepted for MPXV5100GC6U?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPXV5100GC6U transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for MPXV5100GC6U?
MPXV5100GC6U orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your MPXV5100GC6U order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for MPXV5100GC6U?
For technical support, including MPXV5100GC6U datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPXV5100GC6U requirements.
6.How does Aetrix verify that MPXV5100GC6U is sourced from the original manufacturer or authorized distributors?
All MPXV5100GC6U products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPXV5100GC6U meets industry standards.
7.What is the process for return or replacement of MPXV5100GC6U?
All MPXV5100GC6U units undergo pre-shipment inspection (PSI). If there is an issue with MPXV5100GC6U, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The MPXV5100GC6U part is unused and in its original packaging.
Return procedure for MPXV5100GC6U:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
MPXV5100GC6U Tags

-
DPS368XTSA1
Infineon Technologies

-
DPS310XTSA1
Infineon Technologies

-
LPS22HHTR
STMicroelectronics

-
ICP-20100
TDK InvenSense

-
ICP-10110
TDK InvenSense

-
LPS22DFTR
STMicroelectronics

-
LPS22HBTR
STMicroelectronics

-
BMP390
Bosch Sensortec

-
BMP581
Bosch Sensortec

-
BMP384
Bosch Sensortec

-
2511020213301
Würth Elektronik

-
ILPS22QSTR
STMicroelectronics
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…