Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

NXP Semiconductors MPXV5100GP

Part No.:
MPXV5100GP
Manufacturer:
NXP Semiconductors
Category:
Pressure Sensors, Transducers
Package:
8-SMD, Gull Wing, Side Port
Datasheet:
AetrixMPXV5100GP.pdf
Description:
SENSOR 14.5PSIG 0.13" 4.7V 8SOP
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:3,316

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

MPXV5100GP from NXP Semiconductors is a piezoresistive silicon pressure sensor configured for gauge pressure measurement over 0 to 100 kPa, delivering a ratiometric analog output (4.5–4.8 V at full scale with 5 V supply), ±2.5% accuracy over 0–85 °C, and 1 ms response time. It integrates on-chip temperature compensation and is designed for direct interface with microcontroller A/D inputs in medical monitoring and industrial control systems.

For engineers reviewing the MPXV5100GP datasheet, MPXV5100GP pinout, MPXV5100GP application, or MPXV5100GP equivalent, key selection factors include its side-port small-outline package (98ASA99303D), 8-pin configuration with only 4 active terminals, gauge pressure sensing architecture, and compatibility with dry air media in sealed or vented systems.

Technical Context

The MPXV5100GP implements a monolithic silicon shear-stress strain gauge with thin-film metallization and bipolar signal conditioning. Its two-stage gain architecture includes integrated temperature compensation circuitry that corrects offset and span drift across 0–85 °C, enabling stable operation without external calibration components.

It operates ratiometrically with a 4.75–5.25 V supply, producing an output voltage defined by VOUT = VS × (0.009 × P + 0.04), where P is pressure in kPa. The device uses fluorosilicone gel encapsulation to isolate the die while transmitting pressure to the diaphragm, and requires no external decoupling beyond a 1.0 μF bulk capacitor and 0.01 μF ceramic capacitor per the recommended power supply filtering circuit.

Key Specifications

Parameter Value and Actual Design Meaning
Pressure Range 0 to 100 kPa gauge - supports standard atmospheric differential sensing with 15 kPa margin before saturation.
Output Voltage (Full Scale) 4.587–4.813 V at VS = 5.0 V - enables direct connection to 5 V ADC references without level-shifting.
Accuracy ±2.5% of full-scale span (VFSS) - includes linearity, temperature hysteresis, pressure hysteresis, TcSpan, and TcOffset contributions.
Response Time 1.0 ms (10% to 90%) - suitable for dynamic pressure monitoring in pump control and respiratory flow applications.
Supply Voltage 4.75–5.25 VDC - ratiometric operation ensures output scaling tracks supply variations, simplifying system-level calibration.
Operating Temperature −40 to +125 °C - validated for industrial environments; specified accuracy applies over 0–85 °C ambient range.
Sensitivity 45 mV/kPa - yields ~4.5 V output swing across full range, providing high signal-to-noise ratio for 12-bit ADCs.

Pinout & Package

MPXV5100GP uses the 8-lead side-port small outline package (case 98ASA99303D), measuring 10.54 × 10.54 × 12.70 mm, with port located on the long side of the body. Pins 1, 5–8 are internal connections and must remain unconnected.

Pin/Terminal Circuit Role Design Meaning
1 DNC Internal lead frame connection - no external connection permitted; floating or grounded violates specification.
2 VS Positive supply input - requires local 1.0 μF + 0.01 μF decoupling to maintain ratiometric stability and noise immunity.
3 GND Analog ground reference - must be tied to system AGND with low-impedance path to minimize offset error.
4 VOUT Analog output - delivers buffered, temperature-compensated voltage proportional to applied gauge pressure.
5–8 DNC Internal device connections - no routing, soldering, or PCB trace attachment allowed per datasheet Figure 4.

Key Features

Feature Design Value
Piezoresistive silicon shear-stress gauge Monolithic construction eliminates bond wire stress-induced drift, improving long-term zero-point stability.
On-chip temperature compensation Corrects both offset and full-scale span over 0–85 °C without external components or firmware calibration.
Ratiometric output Output scales linearly with supply voltage, removing need for precision voltage references in cost-sensitive systems.
Fluorosilicone gel isolation Protects die and wire bonds from moisture and particulates while maintaining mechanical coupling to pressure port.
Side-port small-outline package Enables compact PCB layout with horizontal pressure access-ideal for space-constrained medical and appliance designs.

Applications

Respiratory Flow Monitoring Pump Pressure Feedback

Use Scenario: Measuring differential airflow pressure across a pneumotachograph in portable ventilators or CPAP devices.

IC Role / Device Role / Timing Role: Gauge pressure transducer converting airway pressure into calibrated analog voltage for microcontroller ADC sampling.

Use Value: 1 ms response time captures rapid inhalation/exhalation transitions; ±2.5% VFSS accuracy ensures reliable tidal volume calculation.

Use Scenario: Closed-loop control of centrifugal or diaphragm pumps in HVAC or water treatment systems.

IC Role / Device Role / Timing Role: Real-time gauge pressure feedback element feeding PID controller to regulate motor speed and flow rate.

Use Value: Ratiometric output eliminates supply rail variation errors; −40 to +125 °C operating range supports outdoor enclosure deployment.

White Goods Pressure Sensing Industrial Process Switching

Use Scenario: Detecting water level or clog conditions in washing machines and dishwashers via chamber pressure changes.

IC Role / Device Role / Timing Role: Low-power gauge sensor interfaced to MCU GPIO or ADC for threshold-based state detection.

Use Value: Durable epoxy unibody construction resists detergent exposure; 0–100 kPa range covers typical drum pressure differentials.

Use Scenario: Triggering safety interlocks or alarms when process pressure exceeds setpoints in pneumatic control panels.

IC Role / Device Role / Timing Role: Analog front-end transducer providing continuous pressure data to programmable logic controller (PLC) input modules.

Use Value: 45 mV/kPa sensitivity yields >4 V output swing - sufficient headroom for noise margin in electrically noisy factory environments.

Equivalent & Alternatives

The following parts are listed as comparable options for similar gauge pressure sensing applications.

Alternative Part Technical Difference Application Difference Selection Advice
MPX5100GP 6-lead unibody package (98ASB42796B); single-port; wider footprint; higher thermal mass. Preferred for through-hole prototyping or legacy board designs requiring larger mounting area. Select MPX5100GP only if board layout accommodates 6-pin unibody form factor and vertical port orientation is acceptable.
MPXV5100GC6U Same 8-lead SO package (98ASB17757C); identical pinout and electrical specs; differs only in tape-and-reel packaging (rail vs tray). No functional difference - GC6U is functionally identical but supplied in rail format for automated placement. Choose MPXV5100GC6U for high-volume SMT production requiring reel-fed pick-and-place; otherwise MPXV5100GP is drop-in compatible.

Compared with MPX5100GP, the MPXV5100GP offers superior board-space efficiency and faster thermal response due to its smaller 8-lead SO package, while MPXV5100GC6U provides identical performance in a different packaging format optimized for automated assembly - neither requires PCB redesign when substituting for MPXV5100GP.

Availability

MPXV5100GP is available at Aetrix Electronics and suitable for respiratory monitoring, pump feedback control, and white goods pressure sensing requiring stable component supply, consistent parametric performance, and long-term lifecycle support.

Supply support for MPXV5100GP includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

NXP Semiconductors is a global semiconductor company headquartered in Eindhoven, Netherlands, specializing in secure connectivity solutions for automotive, industrial, and IoT applications.

The MPXV5100GP belongs to NXP's MPX5100-series piezoresistive pressure sensors, engineered specifically for microcontroller-based systems requiring accurate, temperature-compensated analog pressure outputs in compact surface-mount packages.

FAQ

What pressure type does the MPXV5100GP measure?

The MPXV5100GP is a gauge pressure sensor, meaning it measures pressure relative to ambient atmospheric pressure. Its port is vented to atmosphere, and it delivers an output voltage proportional to the differential between applied pressure and local barometric pressure. This configuration is confirmed in the ordering information table and block diagram for MPXV5100GP in the MPX5100 datasheet Rev. 14.

What is the correct supply voltage range for stable operation of the MPXV5100GP?

The MPXV5100GP operates reliably within a supply voltage range of 4.75 V to 5.25 V DC. Operation outside this window risks violating maximum ratings and degrading accuracy or response time. The device is ratiometric, so output scales linearly with VS - maintaining tight regulation within this band ensures consistent full-scale span and offset performance across temperature.

Can the MPXV5100GP be used with media other than dry air?

No - the MPXV5100GP is qualified and characterized exclusively for use with dry air as the pressure medium. Exposure to liquids, oils, solvents, or corrosive gases may degrade fluorosilicone gel integrity, damage wire bonds, or cause long-term drift. NXP explicitly states in Section 3 of the MPX5100 datasheet that alternative media require factory consultation prior to deployment.

How many pins on the MPXV5100GP are electrically active, and which ones must remain unconnected?

The MPXV5100GP has eight physical leads, but only four are electrically active: Pin 2 (VS), Pin 3 (GND), Pin 4 (VOUT), and Pins 1, 5–8 are designated DNC (Do Not Connect). Connecting any DNC pin to ground, power, or signal traces violates the datasheet specification and may impair accuracy or cause permanent damage.

What is the warm-up time specification for the MPXV5100GP before achieving full accuracy?

The MPXV5100GP requires a maximum warm-up time of 20 ms after power-on and pressure stabilization to meet its full-specified output voltage accuracy. This value is defined in Table 4 of the MPX5100 datasheet under "Warm-up time" and reflects the time needed for internal thermal equilibrium and amplifier settling - critical for applications requiring rapid startup like portable medical devices.

MPXV5100GP Specifications

Product attributes
Attribute value
Manufacturer:
NXP Semiconductors
Series:
MPXV5100
Package/Case:
8-SMD, Gull Wing, Side Port
Packaging:
Tray
Product Status:
Active
Applications:
Board Mount
Pressure Type:
Vented Gauge
Operating Pressure:
14.5PSI (100kPa)
Output Type:
Analog Voltage
Output:
0.2 V ~ 4.7 V
Accuracy:
±2.5%
Voltage - Supply:
4.75V ~ 5.25V
Port Size:
Male - 0.13" (3.17mm) Tube
Port Style:
Barbless
Features:
Temperature Compensated
Termination Style:
Gull Wing
Maximum Pressure:
58.02PSI (400kPa)
Operating Temperature:
-40°C ~ 125°C
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
8-SOP

MPXV5100GP FAQ

1.How can I place an order for MPXV5100GP through Aetrix?

Please submit a Request for Quotation (RFQ) for MPXV5100GP on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for MPXV5100GP reliable?

The price and inventory of MPXV5100GP are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for MPXV5100GP is usually 5 days.

3.What payment methods are accepted for MPXV5100GP?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for MPXV5100GP transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for MPXV5100GP?

MPXV5100GP orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your MPXV5100GP order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for MPXV5100GP?

For technical support, including MPXV5100GP datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your MPXV5100GP requirements.

6.How does Aetrix verify that MPXV5100GP is sourced from the original manufacturer or authorized distributors?

All MPXV5100GP products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that MPXV5100GP meets industry standards.

7.What is the process for return or replacement of MPXV5100GP?

All MPXV5100GP units undergo pre-shipment inspection (PSI). If there is an issue with MPXV5100GP, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The MPXV5100GP part is unused and in its original packaging.

Return procedure for MPXV5100GP:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

MPXV5100GP Tags

  • MPXV5100GP
  • MPXV5100GP PDF
  • MPXV5100GP Datasheet
  • MPXV5100GP Specifications
  • MPXV5100GP Images
  • NXP Semiconductors
  • NXP Semiconductors MPXV5100GP
  • Buy MPXV5100GP
  • MPXV5100GP Price
  • MPXV5100GP Distributor
  • MPXV5100GP Supplier
  • MPXV5100GP Wholesale
Related Products
DPS368XTSA1
DPS368XTSA1

Infineon Technologies

DPS310XTSA1
DPS310XTSA1

Infineon Technologies

LPS22HHTR
LPS22HHTR

STMicroelectronics

ICP-20100
ICP-20100

TDK InvenSense

ICP-10110
ICP-10110

TDK InvenSense

LPS22DFTR
LPS22DFTR

STMicroelectronics

LPS22HBTR
LPS22HBTR

STMicroelectronics

BMP390
BMP390

Bosch Sensortec

BMP581
BMP581

Bosch Sensortec

BMP384
BMP384

Bosch Sensortec

2511020213301
2511020213301

Würth Elektronik

ILPS22QSTR
ILPS22QSTR

STMicroelectronics

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER