onsemi NP0720SCT3G
- Part No.:
- NP0720SCT3G
- Manufacturer:
- onsemi
- Category:
- Thyristors
- Package:
- DO-214AA, SMB
- Datasheet:
-
NP0720SCT3G.pdf
- Description:
- THYRISTOR 65V 100A DO-214AA
- Quantity:
- Payment:

- Shipping:

Inventory:7,886
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
NP0720SCT3G from onsemi is a bidirectional thyristor surge protector (TSPD) designed for overvoltage protection in telecom line interfaces. It features 65 V peak off-state voltage (VDRM), 88 V breakover voltage (VBO), 4.0 V on-state voltage (VT), 150 mA holding current (IH), and supports 2.2 A on-state current (IT). It is used in central office and customer premises equipment to meet GR-1089-CORE and IEC 61000-4-5 surge immunity requirements.
For engineers reviewing the NP0720SCT3G datasheet, pinout, applications, or equivalent options, key selection factors include bidirectional crowbar action, SMB package compatibility, 10×160 µs surge rating up to 90 A(pk), thermal resistance of 90 °C/W, and RoHS-compliant lead-free construction.
Technical Context
The NP0720SCT3G operates as a voltage-triggered bidirectional crowbar device: it remains high-impedance below VDRM (65 V), triggers into low-impedance conduction at VBO (88 V), and latches until current falls below IH (150 mA). Its dv/dt rating is 5.0 kV/s, ensuring robust immunity against fast transients without false triggering.
It is rated for operation from −40 °C to +150 °C, with thermal resistance J-A of 90 °C/W on standard FR4 PCB layout (3″×4.5″, 2 oz copper). Capacitance is 79 pF at 1 MHz/2 Vdc bias - optimized for minimal signal distortion in voice-grade and broadband telecom lines.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| VDRM | 65 V - maximum repetitive off-state voltage both polarities; defines safe operating window before crowbar activation |
| VBO | 88 V - symmetrical breakover voltage threshold; ensures consistent clamping onset across AC waveforms |
| IH | 150 mA - minimum current required to sustain conduction; determines minimum load current needed for reliable latch-off recovery |
| VT | 4.0 V - on-state voltage at 1.0 A(pk); sets power dissipation during surge (P = VT × IT) and limits residual voltage seen by protected circuit |
| Surge Rating (10×160 µs) | 90 A(pk) - non-repetitive surge current capability per TIA-968-A; validates protection against lightning-induced line surges |
| CO | 79 pF - capacitance at 1 MHz/2 Vdc; low enough to avoid signal attenuation in POTS and xDSL applications |
| Package | SMB (DO-214AA) - surface-mount outline with 3.3–3.8 mm width; enables compact telecom board layouts and automated assembly |
Pinout & Package
SMB (DO-214AA) package per JEDEC case 403C, with cathode/anode terminals identified by marking orientation and physical pin assignment.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| MT1 | Anode (Terminal 1) | Primary current entry point during positive half-cycle; forms bidirectional conduction path with MT2 |
| MT2 | Cathode (Terminal 2) | Current return path during positive half-cycle; symmetrically serves as anode during negative half-cycle |
Key Features
| Feature | Design Value |
|---|---|
| Bidirectional crowbar action | Enables single-device protection of AC-coupled telecom lines without polarity-sensitive placement or external diodes |
| Low 79 pF capacitance | Maintains signal integrity in voice-band (0.3–3.4 kHz) and ADSL/VDSL channels without insertion loss or phase shift |
| 150 mA holding current | Ensures reliable self-reset after surge decay while preventing premature turn-off under sustained fault currents |
| RoHS-compliant SMB package | Supports lead-free reflow soldering (J-STD-020) and meets IPC-A-610 Class 2/3 assembly standards |
| GR-1089-CORE & IEC 61000-4-5 compliance | Validated performance against telecom-specific surge waveforms (2×10 µs, 10×1000 µs) and industrial ESD immunity requirements |
Applications
| Central Office Line Cards | DSLAM Protection Modules |
|---|---|
|
Use Scenario: Protecting analog line interface circuits in carrier-class central office switches from lightning-induced surges on outside plant wiring. IC Role / Device Role / Timing Role: Bidirectional crowbar device that clamps transient energy above 88 V and diverts >90 A(pk) away from SLIC and codec ICs. Use Value: Prevents damage to precision analog front-ends while maintaining <3.4 kHz passband integrity due to 79 pF capacitance. |
Use Scenario: Safeguarding ADSL/VDSL line drivers and receivers in digital subscriber line access multiplexers exposed to induced surges on twisted-pair distribution frames. IC Role / Device Role / Timing Role: High-speed voltage-triggered protector that activates within nanoseconds to limit residual voltage to ≤4.0 V during 10×160 µs surges. Use Value: Enables compliance with ITU-T K.21 and GR-1089-CORE without adding series impedance or degrading high-frequency signal fidelity. |
| VoIP Gateway Interfaces | Customer Premises Equipment (CPE) |
|
Use Scenario: Overvoltage protection for FXS/FXO ports in enterprise VoIP gateways connected to PSTN lines. IC Role / Device Role / Timing Role: Bidirectional TSPD that provides fail-safe short-circuit clamping during ring-trip surges and accidental AC power cross-connects. Use Value: Eliminates need for dual unidirectional TVS diodes, reducing BOM count and PCB area by 50% in space-constrained gateway designs. |
Use Scenario: Surge suppression in residential DSL modems, fax machines, and analog telephones installed in regions with poor grounding infrastructure. IC Role / Device Role / Timing Role: Primary overvoltage protector placed at line entry point, rated for 10×1000 µs waveform per IEC 61000-4-5 Level 4. Use Value: Delivers certified immunity to 4 kV line-to-ground surges while sustaining operation over −40 °C to +150 °C ambient range. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar thyristor surge protector applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| NP0720SAT3G | Same electrical specs (VDRM, VBO, IH, etc.), identical SMB package, but marked "072A" instead of "072C" - indicates same die in alternate tape-and-reel configuration | No functional difference; differs only in reel packaging and traceability marking; fully interchangeable in design and assembly | Select NP0720SAT3G when sourcing from distributors offering A-suffix reels or requiring alternate lot traceability format |
| SM712.TCT | Higher VDRM (12 V) and lower VBO (13.5 V); 100 pF capacitance; SO-8 package - not pin-compatible and intended for RS-485, not telecom line protection | Designed for data-line ESD/surge protection (IEC 61000-4-2/4-5), not AC-coupled voice-grade line interfaces | Use SM712.TCT only for low-voltage differential bus protection; not suitable as direct alternative for NP0720SCT3G in telecom line card designs |
Compared with NP0720SAT3G, NP0720SCT3G offers identical protection performance and SMB footprint but with C-suffix marking for distinct supply chain tracking; compared with SM712.TCT, NP0720SCT3G delivers higher voltage handling, lower capacitance, and telecom-specific surge certification - making it the only validated choice for central office and DSLAM applications.
Availability
NP0720SCT3G is available at Aetrix Electronics and suitable for central office line cards, DSLAM protection modules, and VoIP gateway interfaces requiring stable component supply, long-term lifecycle support, and RoHS-compliant manufacturing.
Supply support for NP0720SCT3G includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
onsemi (formerly ON Semiconductor) is a global semiconductor supplier specializing in energy-efficient power, analog, sensor, and connectivity solutions for automotive, industrial, cloud, and communications markets.
The NP Series TSPDs were developed specifically for telecom infrastructure protection - delivering bidirectional crowbar performance, industry-standard surge ratings, and SMB packaging optimized for high-density line card layouts.
FAQ
What is the primary function of the NP0720SCT3G in a telecom circuit?
The NP0720SCT3G functions as a bidirectional thyristor surge protector (TSPD) that acts as a crowbar device: it remains non-conductive below 65 V (VDRM), triggers at 88 V (VBO) during overvoltage events, and diverts surge current away from sensitive downstream components such as SLICs and codecs. Its role in the NP0720SCT3G is to provide fail-safe, low-residual-voltage clamping for AC-coupled telephone line interfaces.
Does the NP0720SCT3G require a gate trigger signal to operate?
No, the NP0720SCT3G is a gateless, voltage-triggered device - it requires no external control signal. Conduction initiates automatically when applied voltage exceeds its symmetrical breakover voltage (VBO = 88 V) in either polarity. Once triggered, it latches on until current drops below its holding current (IH = 150 mA), making the NP0720SCT3G ideal for passive, maintenance-free surge protection.
What is the significance of the "C" suffix in NP0720SCT3G?
Per onsemi's ordering documentation, the "C" suffix in NP0720SCT3G denotes a specific tape-and-reel packaging variant with marking "072C", distinguishing it from "A" and "B" variants (e.g., NP0720SAT3G). All three share identical electrical characteristics, SMB package, and RoHS compliance - the "C" identifies a discrete logistics configuration for traceability and inventory control, not a functional revision of the NP0720SCT3G itself.
Can the NP0720SCT3G be used in DC-powered circuits?
Yes, the NP0720SCT3G is inherently bidirectional and functions identically on DC circuits - it will trigger if DC voltage exceeds ±88 V and remain latched until current falls below ±150 mA. However, its primary validation and application focus is AC-coupled telecom lines (e.g., POTS, xDSL); for pure DC bus protection, ensure the protected load can tolerate the 4.0 V on-state voltage and verify thermal dissipation under sustained fault conditions for the NP0720SCT3G.
How does the NP0720SCT3G compare to TVS diodes for telecom surge protection?
Unlike unidirectional or bidirectional TVS diodes, the NP0720SCT3G uses thyristor-based crowbar action - resulting in lower clamping voltage (4.0 V vs. typical 15–30 V for TVS), higher surge current capacity (90 A vs. ~50 A for comparably sized TVS), and inherent latching behavior. This makes the NP0720SCT3G more effective for high-energy telecom surges where low residual voltage and robust energy diversion are critical, as confirmed in GR-1089-CORE testing.
NP0720SCT3G Specifications
- Product attributes
- Attribute value
- Manufacturer:
- onsemi
- Package/Case:
- DO-214AA, SMB
- Series:
- -
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Obsolete
- Voltage - Breakover:
- 88V
- Voltage - Off State:
- 65V
- Voltage - On State:
- 4 V
- Current - Peak Pulse (8/20µs):
- -
- Current - Peak Pulse (10/1000µs):
- 100 A
- Current - Hold (Ih):
- 150 mA
- Number of Elements:
- 1
- Capacitance:
- 198pF
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- SMB
NP0720SCT3G FAQ
1.How can I place an order for NP0720SCT3G through Aetrix?
Please submit a Request for Quotation (RFQ) for NP0720SCT3G on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for NP0720SCT3G reliable?
The price and inventory of NP0720SCT3G are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for NP0720SCT3G is usually 5 days.
3.What payment methods are accepted for NP0720SCT3G?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for NP0720SCT3G transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for NP0720SCT3G?
NP0720SCT3G orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your NP0720SCT3G order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for NP0720SCT3G?
For technical support, including NP0720SCT3G datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your NP0720SCT3G requirements.
6.How does Aetrix verify that NP0720SCT3G is sourced from the original manufacturer or authorized distributors?
All NP0720SCT3G products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that NP0720SCT3G meets industry standards.
7.What is the process for return or replacement of NP0720SCT3G?
All NP0720SCT3G units undergo pre-shipment inspection (PSI). If there is an issue with NP0720SCT3G, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The NP0720SCT3G part is unused and in its original packaging.
Return procedure for NP0720SCT3G:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
NP0720SCT3G Tags

-
TISP4015L1AJR-S
Bourns Inc.

-
TISP4015L1BJR-S
Bourns Inc.

-
SMP100LC-270
STMicroelectronics

-
TISP4240M3BJR-S
Bourns Inc.

-
SMP100LC-35
STMicroelectronics

-
SMP100LC-65
STMicroelectronics

-
SMP100LC-8
STMicroelectronics

-
TISP4P035L1NR-S
Bourns Inc.

-
TISP4350H3BJR-S
Bourns Inc.

-
TISP4011H1BJR-S
Bourns Inc.

-
SMP100LC-400
STMicroelectronics

-
P0300SALRP
Littelfuse Inc.
Tech Hub
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…