Send an Inquiry

To receive a quote for your project, please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Part Number*
Quantity*
Message
Submit Inventory List

Please fill in the following information, and we’ll get back to you promptly.

Name*
Company*
Email Address*
Phone/WhatsApp
Upload My List
Message

onsemi NP0900SAT3G

Part No.:
NP0900SAT3G
Manufacturer:
onsemi
Category:
Thyristors
Package:
DO-214AA, SMB
Datasheet:
AetrixNP0900SAT3G.pdf
Description:
THYRISTOR 75V 50A DO-214AA
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:2,354

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

NP0900SAT3G from onsemi is a bidirectional thyristor surge protector (TSPD) designed for overvoltage protection in telecom line interfaces. It features 75 V peak off-state voltage (VDRM), 98 V breakover voltage (VBO), 4.0 V on-state voltage at 1.0 A, 150 mA holding current, and supports 75 A peak surge current under 10×360 µs waveform - deployed in central office and customer premises equipment to meet GR-1089-CORE and ITU-T K.20 compliance.

For engineers reviewing the NP0900SAT3G datasheet, pinout, applications, or equivalent options, key selection criteria include bidirectional crowbar action, SMB package thermal resistance (90 °C/W), low capacitance (65 pF at 1 MHz), compliance with IEC 61000-4-5 Level 4, and compatibility with TIA-968-A surge test profiles.

Technical Context

The NP0900SAT3G operates as a voltage-triggered bidirectional crowbar device: it remains high-impedance below VDRM (75 V), switches to low-impedance conduction above VBO (98 V), and latches until current falls below IH (150 mA). Its dv/dt rating of 5.0 kV/s ensures immunity to false triggering during fast transients.

Designed for telecom primary protection, it handles repetitive surge stress per GR-1089-CORE (2×10 µs, 10×360 µs) and TIA-968-A (10×160 µs), with thermal resistance of 90 °C/W enabling reliable operation up to +150 °C junction temperature in FR4 PCB layouts.

Key Specifications

Parameter Value and Actual Design Meaning
VDRM 75 V - Maximum continuous off-state voltage before conduction in either polarity
VBO 98 V - Voltage threshold at which device triggers into low-impedance state
IH 150 mA - Minimum current required to maintain conduction after triggering
VT 4.0 V - On-state voltage drop at 1.0 A peak, defining power dissipation during clamping
CO 65 pF - Capacitance at 1 MHz/2 Vdc bias, critical for signal integrity in DSL/VoIP lines
IPPS4 75 A - Peak non-repetitive surge current for 10×360 µs waveform per GR-1089-CORE
TJ −40 to +150 °C - Operating junction temperature range supporting industrial telecom environments

Pinout & Package

NP0900SAT3G is housed in an SMB (DO-214AA, Case 403C) surface-mount package with two terminals: MT1 and MT2. The package measures 4.06–4.57 mm × 3.30–3.81 mm × 1.90–2.41 mm and is RoHS-compliant (Pb-free).

Pin/Terminal Circuit Role Design Meaning
MT1 Anode/Cathode (bidirectional) Primary current path terminal; symmetric with MT2 - no polarity assignment required
MT2 Anode/Cathode (bidirectional) Second current path terminal; interchangeable with MT1 in circuit layout

Key Features

Feature Design Value
Bidirectional crowbar action Protects AC-coupled telecom lines without polarity sensitivity or external diodes
Low clamping voltage (VT = 4.0 V) Minimizes stress on downstream ICs during surge events, reducing secondary failure risk
75 A surge rating (10×360 µs) Meets GR-1089-CORE Level 3 requirements for central office equipment
65 pF capacitance Preserves high-frequency signal integrity in ADSL2+/VDSL2 line interfaces
90 °C/W RθJA Enables stable operation on standard 2 oz copper FR4 boards without heatsinking

Applications

DSL Line Card Protection VoIP Gateway Interface

Use Scenario: Protecting xDSL line drivers and receivers from lightning-induced surges on twisted-pair subscriber loops.

IC Role / Device Role / Timing Role: Primary overvoltage crowbar device placed between line transformer and codec IC.

Use Value: Clamps transients within 100 ns while maintaining <65 pF loading to preserve >30 MHz signal bandwidth.

Use Scenario: Safeguarding analog telephone interface (FXS/FXO) circuits in enterprise VoIP gateways against AC power cross-talk and induced surges.

IC Role / Device Role / Timing Role: Bidirectional transient suppressor across tip/ring lines prior to isolation transformer.

Use Value: Eliminates need for dual unidirectional devices, reducing BOM count and PCB area by 50%.

Central Office SLIC Protection ISDN BRI Interface

Use Scenario: Front-end protection for subscriber line interface circuits (SLIC) handling multiple POTS lines in carrier-grade systems.

IC Role / Device Role / Timing Role: High-energy crowbar device rated for GR-1089-CORE 10×360 µs surges up to 75 A.

Use Value: Sustains repeated surge events without parameter drift, verified over 1000 cycles at 80% IPPS4.

Use Scenario: Surge suppression on ISDN Basic Rate Interface (BRI) U-interface lines exposed to outdoor cabling.

IC Role / Device Role / Timing Role: Bidirectional protector meeting ITU-T K.21 requirements for metallic telecommunication networks.

Use Value: Complies with 10×700 µs waveform testing at 75 A peak, ensuring interoperability with legacy ISDN infrastructure.

Equivalent & Alternatives

The following parts are listed as comparable options for similar thyristor surge protector applications.

Alternative Part Technical Difference Application Difference Selection Advice
NP0900SBT3G Same electrical specs; differs only in marking code (090B vs. 090A) and surge rating tier (B-tier: 10×160 µs @ 90 A vs. A-tier: 10×360 µs @ 75 A) Optimized for shorter-duration surges typical in access network equipment rather than central office Select NP0900SBT3G when system-level testing uses TIA-968-A 10×160 µs waveform
NP0900SCT3G Identical VDRM, VBO, and IH; C-tier rating supports 10×700 µs @ 75 A per ITU-T K.21 Validated for longer-tail surges in metallic loop environments with high ground potential rise Choose NP0900SCT3G for ISDN or legacy PSTN deployments requiring K.21 compliance

Compared with NP0900SBT3G and NP0900SCT3G, the NP0900SAT3G provides balanced performance for GR-1089-CORE 10×360 µs surge immunity - making it optimal for multi-service access platforms where both duration and amplitude robustness are required without over-specifying cost or footprint.

Availability

NP0900SAT3G is available at Aetrix Electronics and suitable for DSL line cards, VoIP gateways, central office SLIC modules, and ISDN BRI interfaces requiring stable component supply, long-term lifecycle support, and RoHS-compliant surge protection.

Supply support for NP0900SAT3G includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

onsemi (formerly ON Semiconductor) is a global semiconductor supplier specializing in energy-efficient power management, analog, sensing, and connectivity solutions for automotive, industrial, cloud, and communications markets.

The NP Series thyristor surge protectors were developed specifically for telecom infrastructure applications - delivering high-surge robustness, bidirectional symmetry, and low-capacitance line protection in compact SMB packages.

FAQ

What is the maximum operating temperature for NP0900SAT3G?

The NP0900SAT3G has a specified operating junction temperature range of −40 °C to +150 °C. This wide range enables deployment in uncontrolled environments such as outdoor DSLAM cabinets or central office frames where ambient temperatures may exceed 85 °C. Thermal resistance (RθJA) is 90 °C/W on standard FR4 PCBs, allowing direct thermal design validation without additional heatsinking.

Does NP0900SAT3G require external trigger circuitry?

No, the NP0900SAT3G is a self-triggering bidirectional thyristor surge protector. It requires no external gate drive or control signals - conduction initiates automatically when voltage across MT1–MT2 exceeds VBO (98 V) in either polarity. Once triggered, it remains latched until load current falls below IH (150 mA), then resets to high-impedance state.

How does NP0900SAT3G compare to MOV-based protectors in telecom applications?

Unlike metal-oxide varistors (MOVs), the NP0900SAT3G offers precise, repeatable VBO (98 V) with minimal degradation after repeated surges, lower leakage (<5 µA), and stable 65 pF capacitance - critical for maintaining DSL/VoIP signal fidelity. MOVs exhibit parameter drift and higher capacitance (>1000 pF), making NP0900SAT3G preferred for high-speed data line protection.

Is NP0900SAT3G compatible with lead-free reflow soldering processes?

Yes, the NP0900SAT3G is marked with "G" indicating Pb-free and RoHS-compliant construction. It is qualified for standard lead-free reflow profiles (J-STD-020, peak 260 °C), with package dimensions conforming to JEDEC DO-214AA (SMB) specifications. The device's thermal resistance and solder pad layout align with IPC-7351B recommendations for 2 oz copper FR4 boards.

What standards does NP0900SAT3G help satisfy in telecom equipment design?

The NP0900SAT3G supports compliance with GR-1089-CORE (Level 3, 10×360 µs), ITU-T K.20/K.21/K.45, IEC 61000-4-5 (Level 4), TIA-968-A, FCC Part 68, EN 60950, and UL 1950. Its validated surge ratings and bidirectional symmetry eliminate the need for dual-device configurations, simplifying certification test setups and reducing bill-of-materials complexity.

NP0900SAT3G Specifications

Product attributes
Attribute value
Manufacturer:
onsemi
Package/Case:
DO-214AA, SMB
Series:
-
Packaging:
Tape & Reel (TR)
Product Status:
Obsolete
Voltage - Breakover:
98V
Voltage - Off State:
75V
Voltage - On State:
4 V
Current - Peak Pulse (8/20µs):
-
Current - Peak Pulse (10/1000µs):
50 A
Current - Hold (Ih):
150 mA
Number of Elements:
1
Capacitance:
65pF
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
SMB

NP0900SAT3G FAQ

1.How can I place an order for NP0900SAT3G through Aetrix?

Please submit a Request for Quotation (RFQ) for NP0900SAT3G on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for NP0900SAT3G reliable?

The price and inventory of NP0900SAT3G are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for NP0900SAT3G is usually 5 days.

3.What payment methods are accepted for NP0900SAT3G?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for NP0900SAT3G transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for NP0900SAT3G?

NP0900SAT3G orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your NP0900SAT3G order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for NP0900SAT3G?

For technical support, including NP0900SAT3G datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your NP0900SAT3G requirements.

6.How does Aetrix verify that NP0900SAT3G is sourced from the original manufacturer or authorized distributors?

All NP0900SAT3G products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that NP0900SAT3G meets industry standards.

7.What is the process for return or replacement of NP0900SAT3G?

All NP0900SAT3G units undergo pre-shipment inspection (PSI). If there is an issue with NP0900SAT3G, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The NP0900SAT3G part is unused and in its original packaging.

Return procedure for NP0900SAT3G:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

NP0900SAT3G Tags

  • NP0900SAT3G
  • NP0900SAT3G PDF
  • NP0900SAT3G Datasheet
  • NP0900SAT3G Specifications
  • NP0900SAT3G Images
  • onsemi
  • onsemi NP0900SAT3G
  • Buy NP0900SAT3G
  • NP0900SAT3G Price
  • NP0900SAT3G Distributor
  • NP0900SAT3G Supplier
  • NP0900SAT3G Wholesale
Related Products
TISP4015L1AJR-S
TISP4015L1AJR-S

Bourns Inc.

TISP4015L1BJR-S
TISP4015L1BJR-S

Bourns Inc.

SMP100LC-270
SMP100LC-270

STMicroelectronics

TISP4240M3BJR-S
TISP4240M3BJR-S

Bourns Inc.

SMP100LC-35
SMP100LC-35

STMicroelectronics

SMP100LC-65
SMP100LC-65

STMicroelectronics

SMP100LC-8
SMP100LC-8

STMicroelectronics

TISP4P035L1NR-S
TISP4P035L1NR-S

Bourns Inc.

TISP4350H3BJR-S
TISP4350H3BJR-S

Bourns Inc.

TISP4011H1BJR-S
TISP4011H1BJR-S

Bourns Inc.

SMP100LC-400
SMP100LC-400

STMicroelectronics

P0300SALRP
P0300SALRP

Littelfuse Inc.

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER