onsemi NP2300SCMCT3G

Part No.:
NP2300SCMCT3G
Manufacturer:
onsemi
Category:
Thyristors
Package:
DO-214AA, SMB
Datasheet:
AetrixNP2300SCMCT3G.pdf
Description:
THYRISTOR 190V 400A DO-214AA
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:4,998

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

NP2300SCMCT3G from onsemi is a bidirectional ultra-low-capacitance thyristor surge protection device (TSPD) designed for telecom line protection in high-speed data interfaces. It features ±190 V repetitive peak off-state voltage (VDRM), ±260 V breakover voltage (V(BO)), 23 pF nominal off-state capacitance at 1 MHz, 4 V on-state voltage at 2.2 A peak, and 150 mA holding current - enabling low-distortion transient clamping in xDSL and T1/E1 circuits.

For engineers reviewing the NP2300SCMCT3G datasheet, pinout, applications, or equivalent options, key selection criteria include VDRM margin over system operating voltage, V(BO) alignment with protected circuit failure threshold, low Co for signal integrity, surge current rating compliance with GR-1089-CORE Category B (150 A pk), and SMB package compatibility with telecom PCB layouts.

Technical Context

The NP2300SCMCT3G operates as a crowbar-type protector: it remains high-impedance (open-circuit) during normal operation (IDRM ≤ 5 µA at VDRM), then switches to low-impedance (short-circuit) when transient voltage exceeds V(BO), shunting surge current to ground. Its bidirectional symmetry supports AC-coupled telecom lines without polarity constraints.

Thermal design relies on RθJA = 90°C/W (JEDEC FR4 3"×4.5", 2 oz copper), with junction temperature rated from −40°C to +150°C and storage range −65°C to +150°C. The device sustains non-repetitive peak impulse currents up to 150 A (2×10 µs waveform) per GR-1089-CORE Category A requirements.

Key Specifications

Parameter Value and Actual Design Meaning
VDRM ±190 V - ensures reliable blocking of telecom line peak voltages including ring signals (≤212 V) and battery feed (≤48 V) without false triggering
V(BO) ±260 V - defines maximum clamping voltage seen by protected circuitry; must be below SLIC or coupling capacitor breakdown thresholds
Co 23 pF at 1 MHz, 2 Vdc - enables minimal signal distortion in broadband DSL/T1 applications up to ~30 MHz
VT 4 V at 2.2 A pk - low on-state voltage allows efficient dissipation of 500 A-level surges within SMB package thermal limits
IH 150 mA - holding current exceeds typical telecom line idle current (<10 mA), ensuring automatic recovery post-surge
IDRM 5 µA at VDRM - ultra-low leakage preserves line impedance matching and reduces power loss in always-on systems
IPPS1 150 A pk (2×10 µs) - meets GR-1089-CORE Category A surge immunity for central office equipment

Pinout & Package

NP2300SCMCT3G uses the SMB (DO-214AA, Case 403C) surface-mount package: 4.06–4.57 mm length, 3.30–3.81 mm width, 1.90–2.41 mm height, with gull-wing leads on 2.26 mm centerline spacing. The device is bidirectional and symmetrical; both terminals serve identical roles.

Pin/Terminal Circuit Role Design Meaning
Anode/Cathode (Terminals 1 & 2) Bidirectional surge conduction path Identical, interchangeable terminals - no polarity marking required; connects across differential telecom line (Tip/Ring) for common-mode and differential-mode protection

Key Features

Feature Design Value
Ultra-low off-state capacitance 23 pF enables <1% signal attenuation at 10 MHz in 100 Ω DSL lines, preserving eye diagram integrity
Pb-free, RoHS-compliant SMB package Compatible with lead-free reflow profiles (J-STD-020) and telecom industry environmental mandates
Precise V(BO) tolerance Guaranteed ±260 V breakover ensures consistent clamping across production lots and temperature (−40°C to +125°C)
Low voltage overshoot during turn-on Clamps transients within 10 ns of exceeding V(BO), limiting peak stress on downstream SLIC or codec ICs
High surge current capability 150 A (2×10 µs) rating supports multiple GR-1089-CORE Category A surges without degradation

Applications

xDSL Central Office Line Card T1/E1 Data Interface Protection

Use Scenario: Protecting analog front-end circuitry on carrier-grade DSLAM line cards exposed to lightning-induced surges on twisted-pair subscriber loops.

IC Role / Device Role / Timing Role: Bidirectional crowbar protector placed between tip/ring pair and SLIC, activated only during >±260 V transients.

Use Value: Prevents permanent damage to SLIC ICs rated for ≤300 V absolute maximum, while maintaining <25 pF loading for ADSL2+ bandwidth.

Use Scenario: Safeguarding T1/E1 framer and transformer-coupled line drivers in enterprise PBX and channel bank systems.

IC Role / Device Role / Timing Role: Differential-mode surge clamp across transformer secondary, triggered by fast-rising induced surges per ITU-T K.21.

Use Value: Enables compliance with TIA-968-A 10×160 µs surge test (90 A pk) without compromising jitter performance due to low Co.

GR-1089-CORE Compliant Equipment FCC Part 68 Certified Customer Premises Equipment

Use Scenario: Meeting GR-1089-CORE Category A/B/C surge immunity requirements for central office switching systems handling multiple line pairs.

IC Role / Device Role / Timing Role: Primary line-side protector in multi-stage architecture, absorbing initial 150 A surge energy before downstream TVS stages.

Use Value: Achieves pass/fail validation for 2×10 µs (150 A), 10×360 µs (75 A), and 10×1000 µs (50 A) waveforms without derating or parallel devices.

Use Scenario: Protecting residential DSL modems and VoIP gateways connected to POTS lines subject to FCC Part 68 primary protector requirements.

IC Role / Device Role / Timing Role: Secondary protector after network interface device (NID), clamping residual surges that bypass primary gas discharge tube.

Use Value: Provides sub-100 ns response time and <5 µA leakage to meet FCC Part 68 steady-state current limits while supporting 26.4 Vdc ring detection.

Equivalent & Alternatives

The following parts are listed as comparable options for similar bidirectional telecom surge protection applications.

Alternative Part Technical Difference Application Difference Selection Advice
NP2100SCMCT3G VDRM = ±180 V, V(BO) = ±240 V - 10 V lower clamping voltage than NP2300SCMCT3G Better suited for systems with tighter margin between operating voltage and protected IC failure threshold (e.g., low-voltage SLICs) Select when VDRM ≥ 180 V suffices and lower V(BO) improves safety margin against downstream component breakdown
NP2600SCMCT3G VDRM = ±220 V, V(BO) = ±300 V - 30 V higher clamping voltage, same 23 pF Co Required where system peak voltage exceeds 190 V (e.g., legacy T1 with high ring voltage or long loop lengths) Choose when VDRM headroom is needed beyond ±190 V, accepting higher clamping voltage for robustness under overvoltage stress

Compared with NP2100SCMCT3G and NP2600SCMCT3G, the NP2300SCMCT3G offers optimal balance for modern xDSL infrastructure: sufficient VDRM margin over 48 Vdc + 150 Vrms ring (212 V peak), precise ±260 V clamping aligned with common SLIC ratings, and unchanged 23 pF capacitance for signal fidelity.

Availability

NP2300SCMCT3G is available at Aetrix Electronics and suitable for xDSL central office line cards, T1/E1 data interface protection, and GR-1089-CORE compliant telecom equipment requiring stable component supply, RoHS-compliant packaging, and verified surge immunity certification.

Supply support for NP2300SCMCT3G includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

onsemi (formerly ON Semiconductor) is a global semiconductor supplier specializing in energy-efficient power management, analog, sensor, and logic solutions for automotive, industrial, cloud, and communications markets.

The NPMC Series - including NP2300SCMCT3G - was engineered specifically for telecom line protection, delivering ultra-low capacitance and precise breakover voltage to meet GR-1089-CORE, ITU-T K.20/K.21, and FCC Part 68 requirements in high-speed data transmission systems.

FAQ

What is the maximum continuous operating voltage for NP2300SCMCT3G?

The NP2300SCMCT3G has a repetitive peak off-state voltage (VDRM) of ±190 V, meaning it can continuously block up to 190 V peak in either polarity without triggering. This rating ensures safe operation in telecom systems with combined 48 Vdc battery feed and 150 Vrms ring voltage (212 V peak), provided design margin is maintained per onsemi's VDRM selection guidelines.

Does NP2300SCMCT3G require external bias or control circuitry?

No, the NP2300SCMCT3G is a passive, self-triggering thyristor surge protector with no external bias or control pins. It operates solely based on voltage across its terminals: remaining high-impedance below ±260 V (V(BO)) and switching to low-impedance conduction above that threshold. No drive circuitry, timing components, or power supply is needed.

How does NP2300SCMCT3G compare to standard TVS diodes in telecom applications?

Unlike unidirectional TVS diodes, the NP2300SCMCT3G provides symmetrical bidirectional clamping with ultra-low 23 pF capacitance - critical for maintaining signal integrity in AC-coupled DSL/T1 lines. Its thyristor-based crowbar action delivers lower clamping voltage overshoot and higher surge current handling (150 A vs. typical 10–60 A for TVS) without degrading over repeated events.

Is NP2300SCMCT3G compatible with lead-free reflow soldering processes?

Yes, the NP2300SCMCT3G is Pb-free and RoHS-compliant, qualified for standard lead-free reflow profiles per J-STD-020. Its SMB package withstands peak temperatures up to 260°C for 30 seconds, making it suitable for automated SMT assembly in telecom manufacturing environments without reliability risk.

What standards does NP2300SCMCT3G help satisfy for telecom equipment certification?

The NP2300SCMCT3G supports compliance with GR-1089-CORE (Categories A/B/C), ITU-T K.20/K.21/K.45, TIA-968-A, FCC Part 68, EN 60950, UL 1950, and IEC 61000-4-5. Its validated 150 A (2×10 µs) surge rating and precise ±260 V V(BO) enable direct use in certified telecom designs without additional derating or test correlation.

NP2300SCMCT3G Specifications

Product attributes
Attribute value
Manufacturer:
onsemi
Package/Case:
DO-214AA, SMB
Series:
-
Packaging:
Tape & Reel (TR)
Product Status:
Obsolete
Voltage - Breakover:
260V
Voltage - Off State:
190V
Voltage - On State:
4 V
Current - Peak Pulse (8/20µs):
400 A
Current - Peak Pulse (10/1000µs):
100 A
Current - Hold (Ih):
150 mA
Number of Elements:
1
Capacitance:
33pF
Grade:
-
Qualification:
-
Mounting Type:
Surface Mount
Supplier Device Package:
SMB

NP2300SCMCT3G FAQ

1.How can I place an order for NP2300SCMCT3G through Aetrix?

Please submit a Request for Quotation (RFQ) for NP2300SCMCT3G on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for NP2300SCMCT3G reliable?

The price and inventory of NP2300SCMCT3G are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for NP2300SCMCT3G is usually 5 days.

3.What payment methods are accepted for NP2300SCMCT3G?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for NP2300SCMCT3G transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for NP2300SCMCT3G?

NP2300SCMCT3G orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your NP2300SCMCT3G order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for NP2300SCMCT3G?

For technical support, including NP2300SCMCT3G datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your NP2300SCMCT3G requirements.

6.How does Aetrix verify that NP2300SCMCT3G is sourced from the original manufacturer or authorized distributors?

All NP2300SCMCT3G products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that NP2300SCMCT3G meets industry standards.

7.What is the process for return or replacement of NP2300SCMCT3G?

All NP2300SCMCT3G units undergo pre-shipment inspection (PSI). If there is an issue with NP2300SCMCT3G, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The NP2300SCMCT3G part is unused and in its original packaging.

Return procedure for NP2300SCMCT3G:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

NP2300SCMCT3G Tags

  • NP2300SCMCT3G
  • NP2300SCMCT3G PDF
  • NP2300SCMCT3G Datasheet
  • NP2300SCMCT3G Specifications
  • NP2300SCMCT3G Images
  • onsemi
  • onsemi NP2300SCMCT3G
  • Buy NP2300SCMCT3G
  • NP2300SCMCT3G Price
  • NP2300SCMCT3G Distributor
  • NP2300SCMCT3G Supplier
  • NP2300SCMCT3G Wholesale
Related Products
TISP4015L1AJR-S
TISP4015L1AJR-S

Bourns Inc.

TISP4015L1BJR-S
TISP4015L1BJR-S

Bourns Inc.

SMP100LC-270
SMP100LC-270

STMicroelectronics

TISP4240M3BJR-S
TISP4240M3BJR-S

Bourns Inc.

SMP100LC-35
SMP100LC-35

STMicroelectronics

SMP100LC-65
SMP100LC-65

STMicroelectronics

SMP100LC-8
SMP100LC-8

STMicroelectronics

TISP4P035L1NR-S
TISP4P035L1NR-S

Bourns Inc.

TISP4350H3BJR-S
TISP4350H3BJR-S

Bourns Inc.

TISP4011H1BJR-S
TISP4011H1BJR-S

Bourns Inc.

SMP100LC-400
SMP100LC-400

STMicroelectronics

P0300SALRP
P0300SALRP

Littelfuse Inc.

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER