onsemi NP2600SBMCT3G
- Part No.:
- NP2600SBMCT3G
- Manufacturer:
- onsemi
- Category:
- Thyristors
- Package:
- DO-214AA, SMB
- Datasheet:
-
NP2600SBMCT3G.pdf
- Description:
- THYRISTOR 220V 250A DO-214AA
- Quantity:
- Payment:

- Shipping:

Inventory:2,069
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
NP2600SBMCT3G from onsemi is a bidirectional ultra-low-capacitance thyristor surge protection device (TSPD) designed for telecom line protection in xDSL and T1/E1 interfaces. It features ±220 V repetitive peak off-state voltage (VDRM), ±300 V breakover voltage (V(BO)), 23 pF nominal off-state capacitance at 1.0 MHz, 4 V on-state voltage at 2.2 A, and 150 mA holding current - enabling transparent operation and fast crowbar clamping in high-speed data lines.
For engineers reviewing the NP2600SBMCT3G datasheet, pinout, applications, or equivalent options, this device is selected for precise overvoltage threshold control, minimal signal distortion in broadband transmission, compliance with GR-1089-CORE and ITU-T K.20/K.21, and robust 150 A non-repetitive surge current handling per 10×160 µs waveform.
Technical Context
The NP2600SBMCT3G operates as a bidirectional crowbar-type protector: it remains high-impedance (open-circuit) under normal operating conditions up to ±220 V, then switches rapidly to low-impedance (short-circuit) when transient voltage exceeds ±300 V, shunting surge energy to ground. Its 23 pF off-state capacitance ensures linearity and minimal insertion loss up to 100 MHz.
It complies with multiple telecom surge standards including GR-1089-CORE (2×10 µs, 10×360 µs), TIA-968-A (10×160 µs), and ITU-T K.20/K.21 (10×700 µs), supporting Class B and C surge ratings up to 150 A (A), 250 A (B), and 500 A (C) depending on waveform. Thermal resistance is 90 °C/W (Junction-to-Ambient).
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| VDRM | ±220 V - maximum continuous AC/DC voltage before conduction; ensures transparency across 48 V DC + 150 V RMS ring voltage systems |
| V(BO) | ±300 V - guaranteed maximum clamping voltage during surge; protects downstream SLIC and coupling capacitors rated ≤300 V |
| Co | 23 pF @ 1.0 MHz, 1.0 Vrms, 2 Vdc - ultra-low capacitance preserves signal integrity in ADSL/T1/E1 data paths |
| VT | 4 V @ 2.2 A pk, 300 µs pulse - low on-state voltage enables efficient surge dissipation without excessive power loss |
| IH | 150 mA - minimum current to sustain conduction; must exceed system fault-hold current to avoid latch-up |
| IDRM | 5 µA @ VDRM - ultra-low leakage ensures no loading of live telecom lines during standby |
| IPPS (10×160 µs) | 150 A (Class A), 250 A (Class B), 500 A (Class C) - defines surge current capability per industry-standard waveform |
Pinout & Package
NP2600SBMCT3G is housed in an SMB (DO-214AA, Case 403C) surface-mount package with two terminals: Anode and Cathode arranged in a symmetrical bidirectional configuration. The device has no polarity marking; either terminal may serve as input or output in AC line applications.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Anode (A) | Surge current entry point during positive half-cycle | Connects to protected line (e.g., Tip or Ring); forms bidirectional crowbar path with Cathode |
| Cathode (K) | Surge current entry point during negative half-cycle | Connects to protected line opposite Anode; completes symmetrical clamping path to ground reference |
Key Features
| Feature | Design Value |
|---|---|
| Ultra-low off-state capacitance | 23 pF - preserves high-frequency signal fidelity in xDSL (>12 MHz) and T1/E1 (1.5–2.048 MHz) links |
| Precise bidirectional breakover voltage | ±300 V - tightly controlled threshold ensures consistent protection margin across both polarities |
| Low leakage current | 5 µA max @ VDRM - eliminates line loading and avoids false triggering in low-power telecom circuits |
| High surge current rating | 500 A (10×700 µs) - meets GR-1089-CORE Category C requirements for central office equipment |
| Pb-free, RoHS-compliant packaging | SMB (DO-214AA) with matte tin lead finish - compatible with standard reflow profiles and IPC-J-STD-020 |
Applications
| xDSL Central Office Protection | T1/E1 Line Interface |
|---|---|
Use Scenario: Protecting DSLAM line cards from lightning-induced surges on copper subscriber loops. IC Role / Device Role / Timing Role: Bidirectional crowbar protector placed between tip/ring and SLIC, clamping transients before they reach analog front-end. Use Value: 23 pF capacitance prevents attenuation of ADSL2+ upstream signals (up to 30 MHz); ±300 V V(BO) ensures safe margin below SLIC breakdown (typically ±330 V). | Use Scenario: Safeguarding T1/E1 repeater and multiplexer ports against induced surges in carrier networks. IC Role / Device Role / Timing Role: Primary line-side surge suppressor in balanced differential pair, referenced to chassis ground via series impedance. Use Value: 150 mA IH prevents latch-up during sustained 100–150 mA loop currents; ±220 V VDRM supports 100 V RMS T1 signaling with safety margin. |
| Broadband Access Gateway | VoIP Terminal Equipment |
Use Scenario: Integrated protection in residential gateways handling simultaneous POTS and VDSL2 services. IC Role / Device Role / Timing Role: Dual-function protector on shared tip/ring lines, providing fail-safe short-circuit response without affecting voice-band passband (300–3400 Hz). Use Value: 4 V VT minimizes voltage drop during clamping, preserving ringing detection and battery feed integrity during surge events. | Use Scenario: Surge hardening of analog telephone adapters (ATAs) and IP phones connected to PSTN lines. IC Role / Device Role / Timing Role: Secondary protection stage after gas discharge tube (GDT), absorbing residual energy and limiting let-through voltage. Use Value: 23 pF Co avoids resonance with line impedance, eliminating echo or distortion in narrowband voice transmission. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar bidirectional thyristor surge protection applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| NP2600SCMC | Same electrical specs, but in SMC (DO-214AB) package - 5.3 mm × 4.6 mm vs. SMB's 4.6 mm × 3.9 mm | Higher thermal mass and 2× higher IPPS rating (1000 A vs. 500 A for 10×700 µs); suited for central office vs. CPE | Select NP2600SCMC when board space allows and higher surge endurance is required; not drop-in due to footprint change |
| SM15T22CA | TVS diode array (not thyristor); 22 V working voltage, 36.5 V VBR, 1500 W peak power - fundamentally different clamping mechanism | Limited to low-voltage data lines; cannot replace NP2600SBMCT3G in 48 V+ telecom applications due to VDRM mismatch | Only consider SM15T22CA for secondary protection downstream of TSPD; not a functional alternative for primary line protection |
Compared with NP2600SCMC, NP2600SBMCT3G offers identical surge thresholds but reduced footprint and thermal mass - ideal for space-constrained CPE designs. Versus SM15T22CA, it provides true bidirectional crowbar action at telecom-grade voltages, whereas the TVS lacks holding current and fails open under sustained overvoltage.
Availability
NP2600SBMCT3G is available at Aetrix Electronics and suitable for xDSL customer premise equipment, T1/E1 interface modules, and broadband access gateways requiring stable component supply, RoHS-compliant sourcing, and full traceability.
Supply support for NP2600SBMCT3G includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
onsemi (formerly ON Semiconductor) is a global semiconductor supplier specializing in energy-efficient power, analog, sensor, and connectivity solutions for automotive, industrial, cloud, and communications markets.
The NPMC Series - including NP2600SBMCT3G - was engineered specifically for telecom line protection, delivering ultra-low capacitance and precise bidirectional clamping to meet GR-1089-CORE and ITU-T K.20/K.21 requirements.
FAQ
What is the maximum continuous operating voltage for NP2600SBMCT3G?
The NP2600SBMCT3G has a repetitive peak off-state voltage (VDRM) of ±220 V. This means it can safely withstand continuous AC or DC voltages up to ±220 V in the off-state without triggering. It is designed for telecom systems where combined DC battery feed (e.g., 48 V) and AC ring voltage (e.g., 150 V RMS = ~212 V peak) require a minimum VDRM >260 V - so NP2600SBMCT3G is typically used in lower-tier CPE applications or with additional series impedance.
Does NP2600SBMCT3G have polarity-sensitive mounting?
No, NP2600SBMCT3G is a fully bidirectional thyristor device with symmetrical Anode and Cathode terminals. Either terminal may be connected to Tip or Ring in telecom line applications. The SMB package has no polarity marking, and the device functions identically regardless of orientation - a key advantage for protecting AC-coupled differential pairs like T1/E1 or xDSL.
How does NP2600SBMCT3G differ from standard TVS diodes in surge protection?
Unlike unidirectional or bidirectional TVS diodes that clamp with avalanche breakdown, NP2600SBMCT3G uses thyristor-based crowbar action: it latches into a low-voltage on-state (4 V) once triggered and holds until current falls below 150 mA. This provides lower let-through voltage and superior energy handling for long-duration surges (e.g., 10×700 µs), but requires careful IH matching to avoid unintended latch-up - a distinction critical in telecom loop-powered systems.
What is the off-state capacitance of NP2600SBMCT3G and why does it matter?
NP2600SBMCT3G has a nominal off-state capacitance (Co) of 23 pF measured at 1.0 MHz, 1.0 Vrms, and 2 Vdc bias. This ultra-low value minimizes signal attenuation and phase distortion in high-speed data lines - essential for maintaining ADSL2+ upstream bandwidth (>12 MHz) and T1/E1 timing integrity. Capacitance remains stable across voltage (Figure 4), ensuring linear performance up to 50 V bias.
Which regulatory standards does NP2600SBMCT3G help satisfy?
NP2600SBMCT3G supports compliance with GR-1089-CORE (including 2×10 µs, 10×360 µs waveforms), ITU-T K.20/K.21/K.45, TIA-968-A, FCC Part 68, UL 1950, EN 60950, and IEC 61000-4-5. Its specified surge ratings - e.g., 500 A for 10×700 µs - directly map to Category C test levels in GR-1089-CORE, making it suitable for both customer premises and edge network equipment.
NP2600SBMCT3G Specifications
- Product attributes
- Attribute value
- Manufacturer:
- onsemi
- Package/Case:
- DO-214AA, SMB
- Series:
- -
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Obsolete
- Voltage - Breakover:
- 300V
- Voltage - Off State:
- 220V
- Voltage - On State:
- 4 V
- Current - Peak Pulse (8/20µs):
- 250 A
- Current - Peak Pulse (10/1000µs):
- 80 A
- Current - Hold (Ih):
- 150 mA
- Number of Elements:
- 1
- Capacitance:
- 29pF
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- SMB
NP2600SBMCT3G FAQ
1.How can I place an order for NP2600SBMCT3G through Aetrix?
Please submit a Request for Quotation (RFQ) for NP2600SBMCT3G on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for NP2600SBMCT3G reliable?
The price and inventory of NP2600SBMCT3G are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for NP2600SBMCT3G is usually 5 days.
3.What payment methods are accepted for NP2600SBMCT3G?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for NP2600SBMCT3G transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for NP2600SBMCT3G?
NP2600SBMCT3G orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your NP2600SBMCT3G order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for NP2600SBMCT3G?
For technical support, including NP2600SBMCT3G datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your NP2600SBMCT3G requirements.
6.How does Aetrix verify that NP2600SBMCT3G is sourced from the original manufacturer or authorized distributors?
All NP2600SBMCT3G products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that NP2600SBMCT3G meets industry standards.
7.What is the process for return or replacement of NP2600SBMCT3G?
All NP2600SBMCT3G units undergo pre-shipment inspection (PSI). If there is an issue with NP2600SBMCT3G, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The NP2600SBMCT3G part is unused and in its original packaging.
Return procedure for NP2600SBMCT3G:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
NP2600SBMCT3G Tags

-
TISP4015L1AJR-S
Bourns Inc.

-
TISP4015L1BJR-S
Bourns Inc.

-
SMP100LC-270
STMicroelectronics

-
TISP4240M3BJR-S
Bourns Inc.

-
SMP100LC-35
STMicroelectronics

-
SMP100LC-65
STMicroelectronics

-
SMP100LC-8
STMicroelectronics

-
TISP4P035L1NR-S
Bourns Inc.

-
TISP4350H3BJR-S
Bourns Inc.

-
TISP4011H1BJR-S
Bourns Inc.

-
SMP100LC-400
STMicroelectronics

-
P0300SALRP
Littelfuse Inc.
Tech Hub
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…