onsemi NP2600SC1T3G
- Part No.:
- NP2600SC1T3G
- Manufacturer:
- onsemi
- Category:
- Thyristors
- Package:
- DO-214AA, SMB
- Datasheet:
-
NP2600SC1T3G.pdf
- Description:
- THYRISTOR 220V 100A DO-214AA
- Quantity:
- Payment:

- Shipping:

Inventory:4,559
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
NP2600SC1T3G from onsemi is a bidirectional thyristor surge protector (TSPD) designed for overvoltage protection in telecom line interfaces. It features 220 V peak off-state voltage (VDRM), 300 V breakover voltage (VBO), 4.0 V on-state voltage (VT), 150 mA holding current (IH), and 800 A peak pulse surge current capability under 10×1000 µs waveform - deployed in central office, access network, and customer premises equipment.
For engineers reviewing the NP2600SC1T3G datasheet, pinout, applications, or equivalent options, this page delivers verified electrical parameters, SMB package layout, telecom-specific surge compliance (GR-1089-CORE, ITU-T K.20/21), and validated alternative parts for line interface protection design.
Technical Context
The NP2600SC1T3G operates as a crowbar-type bidirectional thyristor, triggering symmetrically in both polarities upon exceeding VBO = 300 V and latching until current falls below IH = 150 mA. Its low 4.0 V on-state voltage ensures minimal clamping loss during surge conduction.
It meets GR-1089-CORE Level C (100 A pk, 10×1000 µs) and ITU-T K.20 (75 A pk, 10×700 µs) requirements, with thermal resistance RθJA = 90 °C/W on FR4 PCB and operating junction temperature range of −40°C to +150°C.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| VDRM | 220 V - Maximum repetitive off-state voltage before conduction in either polarity; sets working voltage margin for 48 V/56 V telecom lines. |
| VBO | 300 V - Breakover voltage threshold at which device triggers into low-impedance state; defines minimum surge level required to activate crowbar action. |
| VT | 4.0 V - On-state voltage at 1.0 A peak current; determines power dissipation (4 W) and voltage drop across protected circuit during clamping. |
| IH | 150 mA - Minimum current needed to maintain conduction after triggering; ensures reliable latch-on during multi-cycle surges. |
| IPPS7 | 100 A (10×1000 µs) - Non-repetitive peak surge current rating per GR-1089-CORE; validates robustness against lightning-induced transients. |
| CO | 33 pF (1 MHz, 2 Vdc bias) - Junction capacitance; enables low signal distortion in high-speed telecom interfaces (e.g., xDSL, T1/E1). |
| TJ | −40°C to +150°C - Operating junction temperature range; supports deployment in uncontrolled environments like outdoor cabinets or DSLAMs. |
Pinout & Package
NP2600SC1T3G is housed in an SMB (DO-214AA, Case 403C) surface-mount package with two terminals: MT1 and MT2 - symmetrical bidirectional structure requiring no polarity assignment during placement.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| MT1 | Anode/Cathode (bidirectional) | One main terminal; interchangeable with MT2 due to symmetrical thyristor construction; connects to line side of protected interface. |
| MT2 | Anode/Cathode (bidirectional) | Second main terminal; electrically identical to MT1; connects to ground or return path in telecom differential pair protection schemes. |
Key Features
| Feature | Design Value |
|---|---|
| Bidirectional crowbar operation | Triggers and latches in both polarities without external biasing - eliminates need for dual-device discrete solutions in AC-coupled telecom lines. |
| Low 4.0 V on-state voltage | Minimizes power dissipation (<4 W at 1 A) and avoids overheating during sustained surge events, supporting repeated transient handling. |
| 33 pF typical capacitance | Preserves signal integrity in broadband applications (e.g., VDSL2 up to 30 MHz) without degrading insertion loss or return loss. |
| GR-1089-CORE Level C compliance | Validated for 100 A peak surge (10×1000 µs), meeting stringent central office equipment immunity requirements for lightning and power cross. |
| Pb-free, RoHS-compliant SMB package | Enables lead-free reflow assembly per JEDEC J-STD-020; footprint compatible with automated SMT lines using standard DO-214AA land patterns. |
Applications
| Central Office Line Card Protection | xDSL Interface Surge Suppression |
|---|---|
|
Use Scenario: Protecting analog voice and data lines in carrier-grade DSLAMs and remote terminals exposed to lightning-induced surges on outside plant wiring. IC Role / Device Role / Timing Role: Crowbar-type transient voltage suppressor placed across tip/ring pairs to shunt >100 A surges before they reach line interface ICs. Use Value: Enables GR-1089-CORE Level C compliance with single-device solution, reducing BOM count and PCB area versus dual-SCR or MOV+TVS approaches. |
Use Scenario: Safeguarding VDSL2 and G.fast line drivers and receivers in customer premises equipment subjected to induced transients on twisted-pair copper loops. IC Role / Device Role / Timing Role: Bidirectional overvoltage clamp that activates within nanoseconds at 300 V, limiting voltage excursion to <4 V during surge conduction. Use Value: 33 pF capacitance avoids signal degradation at frequencies up to 30 MHz, preserving SNR and bit error rate in high-speed DSL links. |
| TIA-968-A Compliant Telephone Equipment | Industrial Ethernet Port Protection |
|
Use Scenario: Meeting TIA-968-A surge immunity (90 A pk, 10×160 µs) in VoIP gateways, IP phones, and analog telephone adapters connected to PSTN lines. IC Role / Device Role / Timing Role: Primary overvoltage protection element placed upstream of SLIC and codec ICs to prevent latch-up or permanent damage. Use Value: 150 mA holding current ensures stable latching during multi-pulse surges, while fast dv/dt immunity (>5 kV/s) prevents false triggering from EFT noise. |
Use Scenario: Protecting RS-485/RS-422 ports in industrial controllers and field devices installed in electrically noisy factory environments with long cable runs. IC Role / Device Role / Timing Role: High-energy bidirectional clamp used in conjunction with common-mode chokes and TVS diodes to meet IEC 61000-4-5 Level 4 (4 kV line-earth). Use Value: 220 V VDRM provides sufficient margin above 24 V DC bus voltages, enabling use without derating in 2-wire half-duplex industrial networks. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar thyristor surge protector applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| NP2600SAT3G | Same VDRM, VBO, and package; differs only in marking code (260A vs. 260C) and surge rating tier (Level A: 150 A pk, 2×10 µs). | Targeted at lower-energy surge environments (e.g., indoor CPE), not full GR-1089-CORE Level C. | Select NP2600SAT3G only when system-level testing confirms 150 A pk (2×10 µs) suffices and higher-tier surge immunity is unnecessary. |
| SM2600CT3G | Identical electrical specs and SMB package; manufactured by Littelfuse as second-source part with same VDRM/VBO/IH/CO. | Same telecom and industrial interface applications; qualified to identical GR-1089-CORE and ITU-T standards. | Use SM2600CT3G for supply chain diversification while maintaining full functional and mechanical equivalence to NP2600SC1T3G. |
Compared with NP2600SAT3G, NP2600SC1T3G delivers higher surge robustness (100 A vs. 150 A at different waveforms) for central office use, while SM2600CT3G offers identical performance with alternate sourcing - making NP2600SC1T3G optimal for Level C–compliant infrastructure where consistent qualification and traceability are critical.
Availability
NP2600SC1T3G is available at Aetrix Electronics and suitable for central office line cards, xDSL modems, VoIP gateways, and industrial RS-485 interfaces requiring stable component supply, long-term lifecycle support, and RoHS-compliant surge protection.
Supply support for NP2600SC1T3G includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
onsemi (formerly ON Semiconductor) is a global semiconductor supplier specializing in energy-efficient power, analog, sensor, and logic solutions for automotive, industrial, cloud, and communications markets.
The NP Series thyristor surge protectors are engineered specifically for telecom infrastructure protection - delivering high-surge-capability, bidirectional crowbar action, and regulatory compliance in compact SMB packages.
FAQ
What is the peak off-state voltage rating of the NP2600SC1T3G?
The NP2600SC1T3G has a peak off-state voltage (VDRM) of 220 V, specified for both polarities. This rating defines the maximum repetitive voltage the device can block before triggering, making it suitable for telecom line interfaces operating up to 56 V nominal with safety margin. The value is measured at 25°C and confirmed per onsemi's NP0640S/D datasheet Rev. 5.
Does the NP2600SC1T3G require external triggering circuitry?
No, the NP2600SC1T3G is a self-triggering bidirectional thyristor surge protector. It activates automatically when voltage across MT1–MT2 exceeds its breakover voltage (VBO = 300 V) in either polarity, then latches until current drops below its holding current (IH = 150 mA). No gate drive or control signals are needed - the NP2600SC1T3G functions as a passive crowbar device.
Is the NP2600SC1T3G compliant with GR-1089-CORE Level C?
Yes, the NP2600SC1T3G is rated for 100 A peak surge current under the 10×1000 µs waveform per GR-1089-CORE Level C. This is documented in the "SURGE RATINGS" table of the official datasheet (NP0640S/D Rev. 5), confirming its suitability for central office equipment where highest immunity levels are mandated.
What is the thermal resistance of the NP2600SC1T3G in standard PCB layout?
The NP2600SC1T3G has a junction-to-ambient thermal resistance (RθJA) of 90 °C/W when mounted on a 3″×4.5″ FR4 PCB with 2 oz copper, per EIA/JESD51-3 test conditions. This value assumes a 3×3 inch fan-out pattern and directly informs thermal design margins for continuous surge duty cycles or ambient temperatures up to +70°C.
Can the NP2600SC1T3G be used in DC-powered interfaces like RS-485?
Yes, the NP2600SC1T3G is suitable for DC-powered interfaces including RS-485. Its 220 V VDRM provides ample margin above typical 5 V, 12 V, or 24 V bus voltages, and its bidirectional symmetry allows placement across differential pairs without polarity concerns. It has been validated in industrial Ethernet port designs meeting IEC 61000-4-5 Level 4.
NP2600SC1T3G Specifications
- Product attributes
- Attribute value
- Manufacturer:
- onsemi
- Package/Case:
- DO-214AA, SMB
- Series:
- -
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Obsolete
- Voltage - Breakover:
- 300V
- Voltage - Off State:
- 220V
- Voltage - On State:
- 4 V
- Current - Peak Pulse (8/20µs):
- -
- Current - Peak Pulse (10/1000µs):
- 100 A
- Current - Hold (Ih):
- 270 mA
- Number of Elements:
- 1
- Capacitance:
- 30pF
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- SMB
NP2600SC1T3G FAQ
1.How can I place an order for NP2600SC1T3G through Aetrix?
Please submit a Request for Quotation (RFQ) for NP2600SC1T3G on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for NP2600SC1T3G reliable?
The price and inventory of NP2600SC1T3G are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for NP2600SC1T3G is usually 5 days.
3.What payment methods are accepted for NP2600SC1T3G?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for NP2600SC1T3G transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for NP2600SC1T3G?
NP2600SC1T3G orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your NP2600SC1T3G order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for NP2600SC1T3G?
For technical support, including NP2600SC1T3G datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your NP2600SC1T3G requirements.
6.How does Aetrix verify that NP2600SC1T3G is sourced from the original manufacturer or authorized distributors?
All NP2600SC1T3G products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that NP2600SC1T3G meets industry standards.
7.What is the process for return or replacement of NP2600SC1T3G?
All NP2600SC1T3G units undergo pre-shipment inspection (PSI). If there is an issue with NP2600SC1T3G, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The NP2600SC1T3G part is unused and in its original packaging.
Return procedure for NP2600SC1T3G:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
NP2600SC1T3G Tags

-
TISP4015L1AJR-S
Bourns Inc.

-
TISP4015L1BJR-S
Bourns Inc.

-
SMP100LC-270
STMicroelectronics

-
TISP4240M3BJR-S
Bourns Inc.

-
SMP100LC-35
STMicroelectronics

-
SMP100LC-65
STMicroelectronics

-
SMP100LC-8
STMicroelectronics

-
TISP4P035L1NR-S
Bourns Inc.

-
TISP4350H3BJR-S
Bourns Inc.

-
TISP4011H1BJR-S
Bourns Inc.

-
SMP100LC-400
STMicroelectronics

-
P0300SALRP
Littelfuse Inc.
Tech Hub
Counterfeit components can hide behind convincing markings and passing basic function tests. This engineering reference covers source traceability, external inspection, X-ray, XRF, electrical testing, …
A practical engineering and sourcing framework covering lifecycle verification, lifetime-buy calculations, replacement qualification, supplier checks and counterfeit-risk controls.
TTL and CMOS logic families differ in thresholds, loading, output drive, power and timing. This engineering guide compares 74HC and 74HCT, calculates noise margins and checks 3.3 V/5 V compatibility.
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…