Diodes Incorporated TB0720H-13
- Part No.:
- TB0720H-13
- Manufacturer:
- Diodes Incorporated
- Category:
- Thyristors
- Package:
- DO-214AA, SMB
- Datasheet:
-
TB0720H-13.pdf
- Description:
- THYRISTOR 65V 400A DO-214AA
- Quantity:
- Payment:

- Shipping:

Inventory:9,230
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
TB0720H-13 from Diodes Incorporated is a bidirectional surface-mount thyristor surge protective device (TSPD) designed for primary-level overvoltage clamping in telecom and data line interfaces. It features a 65 V maximum repetitive off-state voltage (VDRM), 100 A peak pulse current (10/1000 µs), 88 V breakover voltage (VBO), 3.5 V on-state voltage at 1 A, and 200 pF off-state capacitance - enabling robust protection of DSL, T1/E1, and PoE-powered Ethernet ports against lightning-induced surges.
For engineers reviewing the TB0720H-13 datasheet, TB0720H-13 pinout, TB0720H-13 application, or TB0720H-13 equivalent, key selection criteria include stand-off voltage margin relative to line operating voltage, peak surge current rating under IEC 61000-4-5 8/20 µs waveform, holding current compliance with load impedance, thermal resistance (RθJL = 20 °C/W), and UL 497B recognition for telecom safety certification.
Technical Context
This TSPD operates as a voltage-triggered crowbar device: it remains in high-impedance off-state until applied voltage exceeds its 88 V breakover threshold, then latches into low-voltage conduction mode until current falls below 150–800 mA holding current (IH). Its oxide-glass passivated junction ensures stable triggering and long-term reliability under repeated surge stress.
Designed for bidirectional AC line protection, it requires no polarity marking and delivers symmetrical clamping in both directions. The device's 0.1 %/°C positive temperature coefficient of breakdown voltage supports predictable derating across –40 °C to +150 °C junction temperature range, while its 20 °C/W junction-to-lead thermal resistance enables effective heat dissipation into PCB copper.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| VDRM | 65 V - Maximum continuous AC/DC line voltage the device blocks without triggering |
| VBO | 88 V - Voltage threshold at which device switches from blocking to conducting state |
| Ipp (10/1000 µs) | 100 A - Peak surge current capability per GR-1089-CORE standard, defining clamping robustness |
| VT @ IT = 1 A | 3.5 V - Low on-state voltage minimizes power dissipation during clamping events |
| CO | 200 pF - Off-state capacitance measured at 1 MHz/2 V bias; critical for high-speed data line integrity |
| IH | 150–800 mA - Holding current range determines minimum load current required to sustain conduction post-trigger |
| RθJL | 20 °C/W - Junction-to-lead thermal resistance enables direct PCB thermal path design for surge duty cycling |
Pinout & Package
Package: SMB (DO-214AA), surface-mount, bidirectional, polarity-free case with matte tin-plated terminals. Dimensions: 4.3 mm × 3.6 mm × 2.2 mm (L × W × H), UL 94V-0 molded plastic body, moisture sensitivity level 1.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Anode/Cathode (A/K) | Bidirectional main terminals | No fixed polarity; either terminal serves as anode or cathode depending on instantaneous voltage polarity |
| Case | Non-electrical mechanical interface | Insulated plastic housing; no electrical connection or thermal sink requirement beyond PCB copper area |
Key Features
| Feature | Design Value |
|---|---|
| Oxide-glass passivated junction | Ensures stable, repeatable breakover voltage and long operational life under repeated 100 A surge stress |
| Bidirectional single-device protection | Eliminates need for back-to-back diode or dual-TSPD arrangements in AC-coupled telecom lines |
| UL 497B recognition (File E156346) | Validates compliance for primary-side surge protection in telecom central office and customer premises equipment |
| Lead-free & halogen-free construction | Meets RoHS Directive 2002/95/EC and JEDEC M122 green compound requirements for environmental compliance |
Applications
| DSL Line Interface Protection | T1/E1 Data Line Protection |
|---|---|
Use Scenario: Protecting ADSL/VDSL line cards from induced lightning surges on twisted-pair copper loops. IC Role / Device Role / Timing Role: Primary crowbar clamping device placed before line transformer and transceiver IC. Use Value: 65 V VDRM provides 20% margin above 56 V nominal DSL line voltage; 200 pF CO avoids signal distortion at >10 MHz frequencies. | Use Scenario: Safeguarding T1/E1 framing equipment against longitudinal surges entering via balanced 120 Ω or 75 Ω coaxial interfaces. IC Role / Device Role / Timing Role: Bidirectional overvoltage clamp integrated into front-end protection network with gas discharge tube (GDT) coordination. Use Value: 100 A (10/1000 µs) rating meets GR-1089-CORE Level 3 requirements; symmetric conduction eliminates polarity concerns in differential signaling. |
| PoE Power Sourcing Equipment (PSE) | Digital Subscriber Line Access Multiplexer (DSLAM) |
Use Scenario: Protecting 48 V DC PoE injector outputs from reverse-energy surges caused by cable faults or nearby lightning strikes. IC Role / Device Role / Timing Role: Standoff-mode protector placed between PSE controller and Ethernet magnetics. Use Value: 88 V VBO ensures reliable triggering before damage to downstream IEEE 802.3af/at circuitry; 3.5 V VT limits clamping voltage to safe levels during sustained fault. | Use Scenario: Front-end surge suppression in multi-port DSLAM line cards handling up to 24 simultaneous subscriber lines. IC Role / Device Role / Timing Role: Primary-level TSPD mounted directly on PCB near RJ-11 connectors, coordinated with secondary TVS arrays. Use Value: SMB package enables high-density layout; UL 497B listing satisfies Telcordia GR-1089-CORE compliance for central office deployment. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar bidirectional thyristor surge protection applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| Littlefuse SP1003-065 | 65 V VDRM, 100 A Ipp (10/1000 µs), but 150 pF CO and higher 4.2 V VT | Lower capacitance suits higher-frequency xDSL variants; higher VT increases clamping voltage under fault | Select when lower parasitic capacitance is prioritized over lowest possible clamping voltage |
| Littelfuse SP3022-065 | 65 V VDRM, 120 A Ipp (8/20 µs), but unidirectional configuration requiring dual placement | Higher 8/20 µs rating improves IEC 61000-4-5 immunity; bidirectional coverage requires two devices | Select when system-level 400 A (8/20 µs) surge testing drives component-level rating requirements |
Compared with SP1003-065 and SP3022-065, TB0720H-13 offers superior balance of low on-state voltage (3.5 V), certified bidirectionality in one package, and UL 497B listing - making it optimal for space-constrained, safety-certified telecom line card designs where clamping efficiency and regulatory alignment are critical.
Availability
TB0720H-13 is available at Aetrix Electronics and suitable for DSL line interface protection, T1/E1 data line protection, and PoE power sourcing equipment requiring stable component supply, full traceability, and long-term lifecycle support.
Supply support for TB0720H-13 includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Diodes Incorporated is a global manufacturer of discrete semiconductors and analog ICs, headquartered in Plano, Texas, with design, manufacturing, and sales operations across Asia, Europe, and North America.
TB0720H-13 belongs to Diodes' TB-series bidirectional TSPDs - engineered specifically for primary-level surge immunity in telecom infrastructure, meeting GR-1089-CORE, IEC 61000-4-5, and UL 497B standards.
FAQ
What is the maximum operating temperature for TB0720H-13?
The TB0720H-13 has a specified junction temperature range of –40 °C to +150 °C and a storage temperature range of –55 °C to +150 °C. Its thermal resistance from junction to lead is 20 °C/W, allowing reliable operation at full rated surge current when mounted on adequate PCB copper area per the SMB footprint recommendations in DS30360.
Does TB0720H-13 require external triggering or bias circuitry?
No. TB0720H-13 is a self-triggering, voltage-activated thyristor device. It requires no gate drive, control signal, or external bias - switching automatically into low-impedance conduction when applied voltage exceeds its 88 V breakover threshold (VBO), and remaining latched until load current drops below its 150–800 mA holding current (IH).
How does TB0720H-13 coordinate with upstream GDTs or downstream TVS diodes?
TB0720H-13 is typically used as the primary protector in a coordinated cascade: a slow-acting GDT handles high-energy surges first, then the TSPD clamps residual voltage to protect faster secondary TVS devices. Its 100 A (10/1000 µs) rating and 88 V VBO provide precise voltage limiting after GDT sparkover, preventing overstress of downstream silicon-based protectors.
Is TB0720H-13 compliant with RoHS and halogen-free standards?
Yes. TB0720H-13 features a lead-free matte tin finish and green molding compound containing no halogens or antimony, fully compliant with EU Directive 2002/95/EC (RoHS) and JEDEC M122 specifications. Its RoHS status is documented in Diodes' official compliance statements and reflected in its "-13-F" ordering suffix.
TB0720H-13 Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Diodes Incorporated
- Package/Case:
- DO-214AA, SMB
- Series:
- -
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Discontinued at Digi-Key
- Voltage - Breakover:
- 88V
- Voltage - Off State:
- 65V
- Voltage - On State:
- 3.5 V
- Current - Peak Pulse (8/20µs):
- 400 A
- Current - Peak Pulse (10/1000µs):
- 100 A
- Current - Hold (Ih):
- 150 mA
- Number of Elements:
- 1
- Capacitance:
- 200pF
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- SMB
TB0720H-13 FAQ
1.How can I place an order for TB0720H-13 through Aetrix?
Please submit a Request for Quotation (RFQ) for TB0720H-13 on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for TB0720H-13 reliable?
The price and inventory of TB0720H-13 are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for TB0720H-13 is usually 5 days.
3.What payment methods are accepted for TB0720H-13?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for TB0720H-13 transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for TB0720H-13?
TB0720H-13 orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your TB0720H-13 order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for TB0720H-13?
For technical support, including TB0720H-13 datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your TB0720H-13 requirements.
6.How does Aetrix verify that TB0720H-13 is sourced from the original manufacturer or authorized distributors?
All TB0720H-13 products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that TB0720H-13 meets industry standards.
7.What is the process for return or replacement of TB0720H-13?
All TB0720H-13 units undergo pre-shipment inspection (PSI). If there is an issue with TB0720H-13, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The TB0720H-13 part is unused and in its original packaging.
Return procedure for TB0720H-13:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
TB0720H-13 Tags

-
TISP4015L1AJR-S
Bourns Inc.

-
TISP4015L1BJR-S
Bourns Inc.

-
SMP100LC-270
STMicroelectronics

-
TISP4240M3BJR-S
Bourns Inc.

-
SMP100LC-35
STMicroelectronics

-
SMP100LC-65
STMicroelectronics

-
SMP100LC-8
STMicroelectronics

-
TISP4P035L1NR-S
Bourns Inc.

-
TISP4350H3BJR-S
Bourns Inc.

-
TISP4011H1BJR-S
Bourns Inc.

-
SMP100LC-400
STMicroelectronics

-
P0300SALRP
Littelfuse Inc.
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…