STMicroelectronics 1.5KE200CARL
- Part No.:
- 1.5KE200CARL
- Manufacturer:
- STMicroelectronics
- Category:
- TVS Diodes
- Package:
- DO-201AA, DO-27, Axial
- Datasheet:
-
1.5KE200CARL.pdf
- Description:
- TVS DIODE 171VWM 353VC DO201
- Quantity:
- Payment:

- Shipping:

Inventory:9,804
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
1.5KE200CARL from STMicroelectronics is a bidirectional Transil™ TVS diode designed for high-energy transient voltage suppression in DC power lines and signal interfaces. It delivers 1500 W peak pulse power (10/1000 µs), has a 200 V standoff voltage (VRM), 210 V maximum clamping voltage at 274 A IPP, and operates across -65 °C to +175 °C. It protects MOSFETs, microcontrollers, and industrial I/O circuits against ESD and lightning-induced surges.
For engineers reviewing the 1.5KE200CARL datasheet, 1.5KE200CARL pinout, 1.5KE200CARL application, or 1.5KE200CARL equivalent, key selection criteria include clamping ratio (VCL/VBR = 1.05), low dynamic impedance (5.5 Ω), UL 497B certification, and DO-201 package compatibility with high-current PCB layouts.
Technical Context
This device functions as a voltage-clamping surge protector using avalanche breakdown. Its bidirectional configuration enables symmetrical protection on AC-coupled or floating lines without polarity constraints. The 200 V nominal breakdown voltage (VBR = 190–210 V @ 1 mA) ensures precise triggering above system operating voltage while maintaining margin against false trips.
Thermal design relies on junction-to-leads thermal resistance of 20 °C/W and a maximum junction temperature of 175 °C. With 1.08 × 10⁻⁴ /°C voltage temperature coefficient, its VBR drift remains predictable over industrial temperature ranges, supporting stable protection thresholds in varying ambient conditions.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Peak Pulse Power | 1500 W (10/1000 µs): Sustains single lightning-surge events per IEC 61000-4-5 Level 4 without failure. |
| Standoff Voltage (VRM) | 200 V: Maximum continuous reverse voltage before leakage exceeds 1 µA - sets upper limit for protected circuit DC bias. |
| Clamping Voltage (VCL) | 274 V @ 274 A (10/1000 µs): Limits transient voltage seen by downstream ICs to safe levels during surge. |
| Breakdown Voltage (VBR) | 190–210 V @ 1 mA: Defines precise avalanche initiation threshold for repeatable protection timing. |
| Leakage Current (IRM) | 1 µA @ 200 V: Ensures negligible standby power loss and no interference with high-impedance sensor inputs. |
| Capacitance | 675 pF @ 0 V, 1 MHz: Low enough for <1 Mbps RS-485 or 24 V PLC analog I/O, but not suitable for USB or HDMI. |
| Package | DO-201: Through-hole axial lead package with 9.0 mm body length and 25.4 mm lead spacing - supports manual soldering and high-current trace routing. |
Pinout & Package
1.5KE200CARL uses the DO-201 package: epoxy-molded, axial-leaded, UL94 V0 rated, lead-free compliant. Dimensions: 8.5–9.5 mm length (A), 25.4 mm lead spacing (B), 4.8–5.3 mm diameter (C), 0.96–1.06 mm lead diameter (D). Leads are unmarked; polarity is non-applicable due to bidirectional symmetry.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Anode (Lead 1) | Transient current entry point (positive half-cycle) | Conducts surge current into cathode during positive transients; identical electrical behavior to Lead 2. |
| Cathode (Lead 2) | Transient current return path (negative half-cycle) | Completes conduction path during negative transients; functionally interchangeable with Lead 1 in bidirectional operation. |
Key Features
| Feature | Design Value |
|---|---|
| Bidirectional clamping | Enables single-device protection on AC lines, transformer-coupled interfaces, or floating buses without external polarity management. |
| Low clamping factor (VCL/VBR ≈ 1.05) | Minimizes overvoltage stress on protected ICs - critical for 3.3 V or 5 V logic interfacing with 24 V industrial supplies. |
| Fast response time (< 1 ns) | Activates before transient energy couples into sensitive nodes - essential for safeguarding high-speed ADCs and gate drivers. |
| UL 497B certified | Validated for telecom and industrial surge protection per ANSI/UL 497B Annex B - reduces compliance validation effort. |
| High surge current rating (274 A) | Withstands multiple 10/1000 µs surges up to 80% of rated IPP - extends service life in harsh electromagnetic environments. |
Applications
| Industrial PLC Analog Input Modules | DC Power Rail Protection (24 V/48 V) |
|---|---|
Use Scenario: Protecting 0–10 V or 4–20 mA analog input channels from induced surges on factory floor wiring. IC Role / Device Role / Timing Role: Bidirectional voltage clamp placed between input terminal and ground, shunting transients before they reach precision op-amps or SAR ADCs. Use Value: Maintains signal integrity under IEC 61000-4-5 Level 3 (2 kV line-earth) testing with ≤0.5% gain error shift after surge exposure. | Use Scenario: Safeguarding 24 V or 48 V DC power distribution networks in motor drives and HMI panels. IC Role / Device Role / Timing Role: Primary surge suppressor mounted at power entry point, coordinated with upstream fuses and downstream LC filters. Use Value: Clamps 1500 W surges to ≤274 V, preventing latch-up in buck controllers and gate drivers rated for 300 V max input. |
| RS-485/RS-422 Data Lines | AC-DC Adapter Secondary Side |
Use Scenario: Transient protection on differential bus lines exposed to ESD and cable discharge events in building automation systems. IC Role / Device Role / Timing Role: Common-mode clamp connected between A/B lines and ground, leveraging bidirectional symmetry for polarity-agnostic installation. Use Value: Limits common-mode voltage excursion to <300 V during 8 kV contact ESD (IEC 61000-4-2), preserving data integrity at 115.2 kbps. | Use Scenario: Suppressing switching noise and load-dump transients on secondary-side DC outputs of isolated AC-DC adapters. IC Role / Device Role / Timing Role: Final-stage clamp placed after output capacitor, absorbing residual energy from transformer leakage inductance. Use Value: Prevents overvoltage damage to downstream LDOs and microcontrollers during hot-plug or short-circuit recovery events. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar transient voltage suppression applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| SMBJ200CA | Same VBR/VCL specs but SMB package (surface-mount); 600 W rating vs. 1500 W. | Lower power handling limits use to Level 2/3 surges; requires PCB space optimization. | Select when board area is constrained and surge threat level is ≤1 kV (IEC 61000-4-5). |
| 1.5SMC200CA | Same DO-214AB package; 1500 W rating but higher VCL (287 V @ 263 A) and larger footprint than DO-201. | Less optimal thermal path in high-density layouts; requires wider copper pours for heat dissipation. | Choose when existing designs use SMC footprints and require drop-in mechanical compatibility. |
Compared with SMBJ200CA and 1.5SMC200CA, 1.5KE200CARL offers superior surge endurance in through-hole industrial assemblies, tighter clamping ratio, and proven reliability in long-life field deployments - making it preferred for mission-critical 24 V control systems.
Availability
1.5KE200CARL is available at Aetrix Electronics and suitable for industrial PLC analog input modules, DC power rail protection (24 V/48 V), RS-485/RS-422 data lines, and AC-DC adapter secondary-side protection requiring stable component supply and long-term obsolescence management.
Supply support for 1.5KE200CARL includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
STMicroelectronics is a global semiconductor leader headquartered in Geneva, Switzerland, delivering automotive, industrial, and power discrete solutions with vertical manufacturing and broad IP portfolio.
The 1.5KE Transil™ series targets high-reliability transient suppression in industrial and telecom infrastructure, emphasizing robustness, UL certification, and wide voltage range coverage from 6.8 V to 440 V.
FAQ
What is the maximum allowable surge current for 1.5KE200CARL under IEC 61000-4-5 10/1000 µs waveform?
The device sustains 274 A peak pulse current at 274 V clamping voltage per the datasheet's Table 3. This corresponds to full 1500 W rating under standard 10/1000 µs test conditions. Derating applies above 25 °C ambient; at 75 °C, maximum IPP drops to ~220 A due to thermal limits.
Can 1.5KE200CARL be used in AC mains applications?
No - it is rated for DC or low-frequency AC signal/power lines only. Its 200 V VRM and 210 V VBR are insufficient for direct connection to 120/230 VAC mains. For AC line protection, use dedicated MOVs or higher-voltage TVS arrays with appropriate isolation and safety agency approvals.
How does the bidirectional configuration affect PCB layout compared to unidirectional TVS diodes?
Bidirectional operation eliminates polarity marking and orientation checks during assembly, reducing manufacturing errors. Layout requires symmetric trace routing to both leads since either terminal may conduct during positive or negative transients - unlike unidirectional types that demand strict anode/cathode placement relative to ground.
Is 1.5KE200CARL RoHS and REACH compliant?
Yes - the device carries ECOPACK®2 certification per STMicroelectronics' documentation, confirming lead-free terminations, halogen-free epoxy, and full compliance with EU RoHS Directive 2011/65/EU and REACH Regulation (EC) No. 1907/2006. Full material declarations are available via ST's product change notifications.
1.5KE200CARL Specifications
- Product attributes
- Attribute value
- Manufacturer:
- STMicroelectronics
- Package/Case:
- DO-201AA, DO-27, Axial
- Series:
- 1.5KE, TRANSIL™
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Obsolete
- Type:
- Zener
- Unidirectional Channels:
- -
- Bidirectional Channels:
- 1
- Voltage - Reverse Standoff (Typ):
- 171V
- Voltage - Breakdown (Min):
- 190V
- Voltage - Clamping (Max) @ Ipp:
- 353V
- Current - Peak Pulse (10/1000µs):
- 28A (8/20µs)
- Power - Peak Pulse:
- 1500W (1.5kW)
- Power Line Protection:
- No
- Applications:
- General Purpose
- Capacitance @ Frequency:
- 337.5pF @ 1MHz
- Operating Temperature:
- -
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- DO-201
1.5KE200CARL FAQ
1.How can I place an order for 1.5KE200CARL through Aetrix?
Please submit a Request for Quotation (RFQ) for 1.5KE200CARL on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for 1.5KE200CARL reliable?
The price and inventory of 1.5KE200CARL are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 1.5KE200CARL is usually 5 days.
3.What payment methods are accepted for 1.5KE200CARL?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 1.5KE200CARL transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for 1.5KE200CARL?
1.5KE200CARL orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your 1.5KE200CARL order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for 1.5KE200CARL?
For technical support, including 1.5KE200CARL datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 1.5KE200CARL requirements.
6.How does Aetrix verify that 1.5KE200CARL is sourced from the original manufacturer or authorized distributors?
All 1.5KE200CARL products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 1.5KE200CARL meets industry standards.
7.What is the process for return or replacement of 1.5KE200CARL?
All 1.5KE200CARL units undergo pre-shipment inspection (PSI). If there is an issue with 1.5KE200CARL, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The 1.5KE200CARL part is unused and in its original packaging.
Return procedure for 1.5KE200CARL:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
1.5KE200CARL Tags

-
ESD9B5.0ST5G
onsemi

-
DESD3V3E1BL-7B
Diodes Incorporated

-
ESD5Z3.3T1G
onsemi

-
D5V0H1B2LP-7B
Diodes Incorporated

-
D5V0P1B2LP-7B
Diodes Incorporated

-
DESD5V0U1BA-7
Diodes Incorporated

-
ESD5Z5.0T1G
onsemi

-
DESD5V0U1BB-7
Diodes Incorporated

-
D12V0L1B2LP-7B
Diodes Incorporated

-
PESD2V0Y1BSFYL
Nexperia USA Inc.

-
DF2S5M4CT,L3F
Toshiba Semiconductor and Storage

-
D5V0L1B2WS-7
Diodes Incorporated
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…