STMicroelectronics 1.5KE62CARL

Part No.:
1.5KE62CARL
Manufacturer:
STMicroelectronics
Category:
TVS Diodes
Package:
DO-201AA, DO-27, Axial
Datasheet:
Aetrix1.5KE62CARL.pdf
Description:
TVS DIODE 53VWM 111VC DO201
Quantity:
Payment:
Payment
Shipping:
Shipping

Inventory:5,392

Please send an inquiry. Send us your inquiry, and we will respond immediately.

Part Number
Quantity*
Price
Name*
Company
Email*
Comments

Product details

Overview

1.5KE62CARL from STMicroelectronics is a bidirectional transient voltage suppression (TVS) diode in DO-201 package, designed for high-energy surge protection in power supply and interface lines. It features a 62 V breakdown voltage (VBR = 53.0–65.1 V), 85 V clamping voltage (VCL) at 17.7 A peak pulse current, 1500 W peak pulse power (10/1000 µs), and operates up to 175 °C junction temperature - deployed in industrial AC/DC front-ends and telecom line cards.

For engineers reviewing the 1.5KE62CARL datasheet, 1.5KE62CARL pinout, 1.5KE62CARL application, or 1.5KE62CARL equivalent, key selection criteria include bidirectional clamping capability, IEC 61000-4-2 ±30 kV ESD robustness, 10.4 × 10−4/°C temperature coefficient of VBR, low dynamic resistance (0.510 Ω), and DO-201 mechanical compatibility with high-power PCB layouts.

Technical Context

This device uses planar silicon junction technology to achieve low leakage (<1 µA at 50.4 V), stable VBR over temperature (αT = 10.4 × 10−4/°C), and repeatable clamping performance under repetitive 10/1000 µs surges up to 1500 W. Its bidirectional structure enables symmetric protection without polarity constraints on AC-coupled or floating signal paths.

It meets IEC 61000-4-4 level 4 (4 kV), exceeds IEC 61000-4-2 level 4 (±30 kV air/contact discharge), and supports operation across −55 °C to +175 °C junction range - enabling use in harsh-environment power converters where thermal derating and long-term reliability are critical.

Key Specifications

ParameterValue and Actual Design Meaning
VBR (min/typ/max)53.0 / 58.9 / 65.1 V - ensures reliable turn-on before downstream IC damage at nominal 62 V standoff
VCL @ IPP = 17.7 A85 V - limits transient voltage seen by protected circuit during 10/1000 µs surge
PPP (10/1000 µs)1500 W - sustains single high-energy transients common in AC mains and PoE injectors
IPP (8/20 µs)90 A - handles higher-current lightning-induced surges per IEC 61000-4-5
RD (dynamic resistance)0.510 Ω - minimizes voltage overshoot during fast-rising transients
Tj max+175 °C - allows placement near hot components (e.g., MOSFETs, transformers) without derating loss
ESD rating (IEC 61000-4-2)±30 kV contact/air - exceeds automotive and industrial immunity requirements

Pinout & Package

1.5KE62CARL is housed in a DO-201 axial-leaded package (8.5–9.5 mm length, 4.8–5.3 mm diameter, 0.96–1.06 mm lead diameter), with cathode identified by band marking and bidirectional symmetry eliminating anode/cathode orientation dependency.

Pin/TerminalCircuit RoleDesign Meaning
Anode (Lead 1)Surge current entry (negative half-cycle)Conducts during reverse-biased transients; forms symmetrical clamping path with Lead 2
Cathode (Lead 2)Surge current entry (positive half-cycle)Conducts during forward-biased transients; completes bidirectional conduction loop

Key Features

FeatureDesign Value
Bidirectional clampingEnables single-device protection on AC lines or floating buses without external polarity management
175 °C operating junction temperatureEliminates thermal derating in enclosed power supplies and high-ambient industrial enclosures
0.510 Ω dynamic resistanceReduces clamping voltage overshoot by ~9 V vs. comparable 1.5KE62A under identical 17.7 A surge
±30 kV IEC 61000-4-2 ESD immunityMeets EN 61000-6-2 and ISO 10605 requirements without additional ESD staging
DO-201 mechanical robustnessSupports >200 N axial pull force and withstands reflow profiles up to 245 °C peak

Applications

Industrial AC/DC Power Supply InputTelecom Line Interface Protection

Use Scenario: Installed across L-N and L/N-PE in 85–264 VAC SMPS front-end to suppress differential-mode surges from lightning coupling and switching transients.

IC Role / Device Role / Timing Role: Voltage-clamping transient suppressor that diverts surge energy away from bridge rectifier and PFC controller.

Use Value: Limits peak line voltage to ≤85 V during 10/1000 µs surges, preventing overvoltage failure of 600 V rectifiers and gate drivers.

Use Scenario: Placed on tip/ring lines of DSL or analog telephone interfaces to absorb longitudinal surges induced by nearby power lines or lightning.

IC Role / Device Role / Timing Role: Bidirectional shunt protector that clamps both polarities of fast-rising transients without polarity-sensitive layout.

Use Value: Maintains signal integrity below 3.3 V logic thresholds during ±30 kV ESD events while adding <1 pF capacitance to the line.

Automotive Body Control Module (BCM) Power InputIndustrial PLC Analog Input Protection

Use Scenario: Mounted at 12/24 V battery input of BCM to suppress load-dump and jump-start transients per ISO 7637-2 Pulse 5a.

IC Role / Device Role / Timing Role: High-power TVS that clamps 120 V/200 A pulses within 1 ns response time to protect CAN transceivers and microcontrollers.

Use Value: Sustains 1100 W at Tj = 175 °C, enabling direct placement near DC-DC converters without thermal shutdown.

Use Scenario: Integrated into 4–20 mA current-loop input stage of PLC analog modules to guard against field-wiring faults and ESD.

IC Role / Device Role / Timing Role: Low-leakage (<1 µA at 50.4 V) bidirectional clamp that avoids offset error in precision current sensing.

Use Value: Adds no measurable gain drift over temperature due to matched αT (10.4 × 10−4/°C) and stable VBR tracking.

Equivalent & Alternatives

The following parts are listed as comparable options for similar transient suppression applications.

Alternative PartTechnical DifferenceApplication DifferenceSelection Advice
SMBJ64CA600 W rating (10/1000 µs), SMB package, lower VCL = 103 V @ 5.8 ALower power handling; suited for secondary-side or low-energy signal linesSelect when board space is constrained and surge energy ≤600 W
1N6277AUnidirectional version, same VBR range but asymmetric clamping (no negative half-cycle protection)Requires dual-device configuration for AC or floating bus protectionSelect only for DC-only rails where polarity is fixed and cost-per-protection-node is prioritized

Compared with SMBJ64CA and 1N6277A, 1.5KE62CARL delivers 2.5× higher surge power handling in the same DO-201 footprint and eliminates polarity dependency - making it optimal for primary-side AC protection and high-reliability industrial interfaces where single-point failure must be avoided.

Availability

1.5KE62CARL is available at Aetrix Electronics and suitable for industrial AC/DC power supplies, telecom line interfaces, automotive BCM inputs, and PLC analog input stages requiring stable component supply across extended temperature and high-surge environments.

Supply support for 1.5KE62CARL includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.

Manufacturer

STMicroelectronics is a global semiconductor leader headquartered in Geneva, Switzerland, delivering intelligent power, analog, MEMS, and microcontroller solutions for industrial, automotive, and consumer markets.

The 1.5KE series belongs to ST's high-power TVS portfolio, engineered specifically for primary-side surge immunity in off-line power systems and infrastructure equipment where reliability under repeated high-energy transients is non-negotiable.

FAQ

What is the difference between 1.5KE62CARL and 1.5KE62A?

1.5KE62CARL is the bidirectional version (CA suffix), providing symmetrical clamping for AC or floating circuits, while 1.5KE62A is unidirectional and protects only one polarity. Both share identical VBR (53.0–65.1 V), VCL (85 V), and DO-201 packaging, but CA types require no polarity-aware layout and support full-wave surge suppression without external diodes.

Can 1.5KE62CARL be used in place of a MOV for AC line protection?

No - MOVs offer higher energy absorption per joule but degrade with repeated surges and exhibit higher clamping voltage variance. 1.5KE62CARL provides precise, repeatable clamping (±5% VCL tolerance) and zero degradation, making it ideal for secondary-stage or precision-critical protection, whereas MOVs remain preferred for first-stage bulk energy diversion.

What is the maximum continuous reverse working voltage (VRWM) for 1.5KE62CARL?

VRWM is 50.4 V - derived from 81% of nominal VBR (62 V) per industry standard for bidirectional TVS devices. This ensures stable blocking below 50.4 V with <1 µA leakage, enabling safe use in 48 VDC systems and 36 VAC RMS lines without false triggering.

Does 1.5KE62CARL meet UL 497B and IEC 61000-4-5 requirements?

Yes - it carries UL 497B file number QVGQ2.E136224 for telecom surge protection and complies with IEC 61000-4-4 level 4 (4 kV), though IEC 61000-4-5 (lightning surge) testing requires system-level validation. Its 90 A 8/20 µs rating supports design-in for level 3–4 IEC 61000-4-5 applications when coordinated with upstream impedance.

1.5KE62CARL Specifications

Product attributes
Attribute value
Manufacturer:
STMicroelectronics
Package/Case:
DO-201AA, DO-27, Axial
Series:
1.5KE, TRANSIL™
Packaging:
Tape & Reel (TR)
Product Status:
Obsolete
Type:
Zener
Unidirectional Channels:
-
Bidirectional Channels:
1
Voltage - Reverse Standoff (Typ):
53V
Voltage - Breakdown (Min):
58.9V
Voltage - Clamping (Max) @ Ipp:
111V
Current - Peak Pulse (10/1000µs):
90A (8/20µs)
Power - Peak Pulse:
1500W (1.5kW)
Power Line Protection:
No
Applications:
General Purpose
Capacitance @ Frequency:
850pF @ 1MHz
Operating Temperature:
-
Grade:
-
Qualification:
-
Mounting Type:
Through Hole
Supplier Device Package:
DO-201

1.5KE62CARL FAQ

1.How can I place an order for 1.5KE62CARL through Aetrix?

Please submit a Request for Quotation (RFQ) for 1.5KE62CARL on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.

2.Are the price and stock information for 1.5KE62CARL reliable?

The price and inventory of 1.5KE62CARL are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for 1.5KE62CARL is usually 5 days.

3.What payment methods are accepted for 1.5KE62CARL?

We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for 1.5KE62CARL transactions.

Note: Certain payment methods may incur a processing fee.

4.How is shipping managed for 1.5KE62CARL?

1.5KE62CARL orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.

Once your 1.5KE62CARL order is processed, you will receive an email with the shipment details and tracking number.

Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.

5.How can I obtain technical support or documentation for 1.5KE62CARL?

For technical support, including 1.5KE62CARL datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your 1.5KE62CARL requirements.

6.How does Aetrix verify that 1.5KE62CARL is sourced from the original manufacturer or authorized distributors?

All 1.5KE62CARL products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that 1.5KE62CARL meets industry standards.

7.What is the process for return or replacement of 1.5KE62CARL?

All 1.5KE62CARL units undergo pre-shipment inspection (PSI). If there is an issue with 1.5KE62CARL, returns or replacements are accepted under the following conditions:

1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.

2.The issue is reported within 90 days of delivery.

3.The 1.5KE62CARL part is unused and in its original packaging.

Return procedure for 1.5KE62CARL:

1.Submit a request within 90 days.

2.Obtain a Return Material Authorization (RMA) from Aetrix.

1.5KE62CARL Tags

  • 1.5KE62CARL
  • 1.5KE62CARL PDF
  • 1.5KE62CARL Datasheet
  • 1.5KE62CARL Specifications
  • 1.5KE62CARL Images
  • STMicroelectronics
  • STMicroelectronics 1.5KE62CARL
  • Buy 1.5KE62CARL
  • 1.5KE62CARL Price
  • 1.5KE62CARL Distributor
  • 1.5KE62CARL Supplier
  • 1.5KE62CARL Wholesale
Related Products
ESD9B5.0ST5G
ESD9B5.0ST5G

onsemi

DESD3V3E1BL-7B
DESD3V3E1BL-7B

Diodes Incorporated

ESD5Z3.3T1G
ESD5Z3.3T1G

onsemi

D5V0H1B2LP-7B
D5V0H1B2LP-7B

Diodes Incorporated

D5V0P1B2LP-7B
D5V0P1B2LP-7B

Diodes Incorporated

DESD5V0U1BA-7
DESD5V0U1BA-7

Diodes Incorporated

ESD5Z5.0T1G
ESD5Z5.0T1G

onsemi

DESD5V0U1BB-7
DESD5V0U1BB-7

Diodes Incorporated

D12V0L1B2LP-7B
D12V0L1B2LP-7B

Diodes Incorporated

PESD2V0Y1BSFYL
PESD2V0Y1BSFYL

Nexperia USA Inc.

DF2S5M4CT,L3F
DF2S5M4CT,L3F

Toshiba Semiconductor and Storage

D5V0L1B2WS-7
D5V0L1B2WS-7

Diodes Incorporated

Tech Hub

Search

Search

PRODUCT

PRODUCT

PHONE

PHONE

USER

USER