NXP Semiconductors NHS3152UK/A1Z
- Part No.:
- NHS3152UK/A1Z
- Manufacturer:
- NXP Semiconductors
- Category:
- RFID, RF Access, Monitoring ICs
- Package:
- 25-UFBGA, WLCSP
- Datasheet:
-
NHS3152UK/A1Z.pdf
- Description:
- IC RFID READER 13.56MHZ 25WLCSP
- Quantity:
- Payment:

- Shipping:

Inventory:415
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
NHS3152UK/A1Z from NXP Semiconductors is a therapy adherence resistive monitor IC integrating an Arm Cortex-M0+ processor, NFC/RFID ISO 14443 Type A interface, six-channel analog I/O with temperature sensor (±0.3 °C accuracy from 0 °C to +45 °C), and ultra-low-power operation down to <50 nA in battery-off mode - designed for single-layer foil pill-bottle or blister-pack usage logging.
For engineers reviewing the NHS3152UK/A1Z datasheet, NHS3152UK/A1Z pinout, NHS3152UK/A1Z application, or NHS3152UK/A1Z equivalent, this page delivers verified specifications, WLCSP25 package mapping, NFC-powered vs. battery-powered operational modes, and real-world therapy monitoring use cases - all grounded in NXP's Rev. 5.02 product data sheet.
Technical Context
The NHS3152UK/A1Z implements a dual-power architecture with automatic source selection between VDDBAT (1.72–3.6 V) and NFC-field-derived power, enabling passive and active operation without external regulators. Its Arm Cortex-M0+ core runs at up to 8 MHz (with programmable clock dividers down to 62.5 kHz) and includes NVIC, SWD debug, and system tick timer.
Analog subsystem integration includes a flexible on-chip analog switch matrix routing six AN0_x pins to shared ADC/DAC/CDC converters via time-division multiplexing, plus dedicated temperature sensing with ±0.3 °C accuracy over the clinical range (0 °C to +45 °C). Power management supports five discrete states: Active, Sleep, Deep-sleep, Deep power-down, and Battery-off - each with domain-specific LDO control (1.2 V and 1.6 V).
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| CPU Core | Arm Cortex-M0+ running up to 8 MHz - enables firmware-defined therapy logic and local decision-making without host MCU. |
| Memory | 32 kB flash + 8 kB SRAM + 4 kB EEPROM (320 B write-protected) - sufficient for secure log storage and firmware updates in constrained medical edge devices. |
| NFC Interface | ISO 14443 Type A, NFC Forum Type 2 certified (ID 58524) - enables tap-to-read compliance data without batteries or connectors. |
| Temperature Sensor | ±0.3 °C absolute accuracy from 0 °C to +45 °C - meets clinical-grade thermal validation requirements for medication storage environment monitoring. |
| Power Modes | Five states including Battery-off (<50 nA @ 3.0 V) - extends shelf life of unpowered smart packaging until first NFC activation or battery connection. |
| Analog I/O | 6 configurable analog pins (AN0_0 to AN0_5) routed via on-chip switch matrix to shared ADC/DAC/CDC - supports resistive network sensing for multi-pill blister detection. |
| I/O Pins | 12 GPIO with interrupt capability, 4 high-current sink drivers (20 mA), I²C (400 kbit/s), SPI, and SWD - enables direct foil trace interfacing and debug during development. |
Pinout & Package
Package: WLCSP25 (2.51 × 2.51 × 0.5 mm, SOT1401-1), ball-grid layout optimized for ultra-thin medical packaging integration.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| A1 | VDDBAT | Main positive supply input (1.72–3.6 V); powers digital/analog domains when active and higher than NFC voltage. |
| A2, C3 | VSS | Digital ground reference; dual-ball connection improves low-impedance return path for noise-sensitive analog measurements. |
| A3 | RESETN | Active-low external reset; weak internal pull-up to highest available supply (VDDBAT or VNFC) ensures reliable boot initialization. |
| A4, A5 | SCL / SDA | I²C-bus interface (400 kbit/s fast mode); open-drain configuration supports multi-drop communication with external sensors or controllers. |
| D1 | PIO0_0/WAKEUP | Deep power-down wake-up input; must be pulled LOW ≥100 μs to exit DEEPPDN - used for foil-break or button-triggered event logging. |
| E4, E5 | LA / LB | NFC antenna terminals; differential connection to external coil enables passive RF energy harvesting and bidirectional command exchange. |
| E1–E3, D3, D4, D5 | AN0_0 to AN0_5 | 6 analog I/O pins; software-configurable as inputs to ADC/CDC or outputs from DAC - forms resistive network interface for pill-count verification. |
Key Features
| Feature | Design Value |
|---|---|
| Embedded NFC + Battery Dual-Power Operation | Enables zero-battery shelf life and post-deployment activation via NFC tap - eliminates need for pre-installation battery charging or replacement. |
| Configurable Analog Switch Matrix | Allows time-multiplexed measurement of all six AN0_x pins using single ADC/DAC/CDC instances - reduces silicon area and power vs. per-channel converters. |
| Ultra-Low-Power Battery-Off Mode | <50 nA current draw at 3.0 V preserves shelf life >5 years in unpowered smart packaging - critical for OTC and prescription adherence solutions. |
| On-Chip Temperature Sensing | ±0.3 °C accuracy over 0–45 °C clinical range - validates medication storage conditions without external sensor calibration or BOM cost. |
| Arm SWD Debug Support | Serial Wire Debug (SWCLK/SWDIO on B5/C5) enables in-system firmware update and real-time debugging during device qualification and field deployment. |
Applications
| Smart Pill Bottle Monitoring | Blister-Pack Adherence Tracking |
|---|---|
|
Use Scenario: Integrated into cap electronics of prescription bottles to detect lid opening events and log timestamped access. IC Role / Device Role / Timing Role: NHS3152UK/A1Z acts as standalone data logger and NFC responder - senses mechanical actuation via resistive foil break and reports compliance history on tap. Use Value: Eliminates reliance on user-initiated app entries; provides tamper-evident, time-stamped adherence records readable by pharmacy or clinician NFC readers. |
Use Scenario: Embedded beneath conductive foil layers of pharmaceutical blister packs to detect pill removal via resistance change across segmented traces. IC Role / Device Role / Timing Role: NHS3152UK/A1Z serves as foil-integrated resistive monitor and local counter - measures analog voltage shifts on AN0_x pins to infer pill count and stores results in EEPROM. Use Value: Enables per-dose verification without visual inspection; supports regulatory audit trails with cryptographically signed logs stored on-chip. |
| Passive Medical Device Authentication | Temperature-Validated Medication Storage |
|
Use Scenario: Used in diagnostic test kits to authenticate genuine manufacturer components and prevent counterfeit reagent cartridges. IC Role / Device Role / Timing Role: NHS3152UK/A1Z functions as secure identity token - stores unique serial number and digitally signs challenge-response exchanges over NFC. Use Value: Provides hardware-rooted authentication without external secure element; leverages built-in flash EEPROM for key storage and firmware integrity checks. |
Use Scenario: Monitors ambient temperature inside insulin or biologic vial carriers during transport and storage. IC Role / Device Role / Timing Role: NHS3152UK/A1Z operates as autonomous thermal logger - samples temperature sensor every 15 minutes and flags excursions beyond 2–8 °C thresholds. Use Value: Delivers clinically relevant thermal history with ±0.3 °C accuracy - satisfies WHO PQS and FDA cold-chain validation requirements without external sensor chains. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar therapy adherence monitoring applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| ST25DV64K | NFC EEPROM only (no MCU, no analog sensing, no temperature sensor); 64-kbit memory; I²C + RF interface. | Limited to passive data storage; cannot execute custom logic, perform resistive sensing, or log temperature - requires companion MCU. | Select when only NFC-accessible static data storage is needed; not suitable as standalone adherence monitor. |
| MAX32665 | Arm Cortex-M4F MCU with BLE, 2 MB flash, but no integrated NFC or resistive sensing front-end; requires external NFC chip and analog circuitry. | Supports richer connectivity and processing, but increases BOM count, PCB area, and power consumption - lacks NHS3152UK/A1Z's foil-integration optimization. | Choose for Bluetooth-enabled remote reporting where NFC tap-read is secondary; verify analog signal chain design effort. |
Compared with ST25DV64K and MAX32665, NHS3152UK/A1Z uniquely integrates NFC, Arm M0+, analog sensing, and ultra-low-power operation in one WLCSP die - eliminating external components required for foil-based pill monitoring and reducing total system footprint by >40%.
Availability
NHS3152UK/A1Z is available at Aetrix Electronics and suitable for smart packaging, medical device authentication, and temperature-validated drug storage requiring stable component supply across long-lifecycle healthcare programs.
Supply support for NHS3152UK/A1Z includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
NXP Semiconductors is a global semiconductor leader specializing in secure connectivity solutions for automotive, industrial, and healthcare markets - with deep expertise in NFC, ultra-low-power MCUs, and medical-grade sensing.
The NHS3152UK/A1Z belongs to NXP's therapy adherence monitor product line, engineered specifically for battery-free or long-shelf-life smart packaging applications where miniaturization, NFC accessibility, and clinical-grade analog accuracy are mandatory.
FAQ
What power sources does the NHS3152UK/A1Z support?
The NHS3152UK/A1Z supports dual power sources: external battery (1.72–3.6 V via VDDBAT) and passive NFC-field harvesting (via LA/LB terminals). An internal automatic source selector prioritizes VDDBAT when both are present. In battery-off mode, current draw is <50 nA - enabling multi-year shelf life before first activation. The NHS3152UK/A1Z enters active mode upon NFC field detection or RESETN assertion.
How does the NHS3152UK/A1Z interface with resistive foil networks for pill counting?
The NHS3152UK/A1Z uses its six AN0_x analog I/O pins (AN0_0 to AN0_5) connected to segmented foil traces. Through its on-chip analog switch matrix and shared ADC/CDC, it performs time-division multiplexed resistance measurements to detect breaks or continuity changes indicating pill removal. Firmware interprets voltage shifts to increment dose counters stored in EEPROM - all without external analog components. This capability is intrinsic to the NHS3152UK/A1Z architecture.
Is the NHS3152UK/A1Z NFC Forum certified?
Yes, the NHS3152UK/A1Z is NFC Forum Type 2 certified with certification ID 58524 (as of September 25, 2017). It complies fully with ISO/IEC 14443 Type A standards and supports standard NFC read/write operations - enabling interoperability with smartphones, point-of-care readers, and pharmacy systems without proprietary drivers. This certification applies directly to the NHS3152UK/A1Z in WLCSP25 packaging.
What is the temperature accuracy specification of the NHS3152UK/A1Z sensor?
The NHS3152UK/A1Z integrated temperature sensor achieves ±0.3 °C absolute accuracy between 0 °C and +45 °C - the clinically critical range for medication storage. Accuracy degrades to ±0.5 °C outside that band (−40 °C to 0 °C and +45 °C to +85 °C). Calibration is factory-trimmed; no user compensation is required. This performance is specified and guaranteed for the NHS3152UK/A1Z across its operating voltage and temperature range.
Can the NHS3152UK/A1Z be programmed in-system after assembly?
Yes, the NHS3152UK/A1Z supports in-system programming via Arm Serial Wire Debug (SWD) using the SWCLK and SWDIO pins (B5 and C5 in WLCSP25). It also allows firmware updates over NFC using the built-in bootloader. Both methods preserve EEPROM log data and support secure signature verification. Development toolchains including MCUXpresso IDE fully support the NHS3152UK/A1Z - no special hardware programmers are required beyond standard SWD probes.
NHS3152UK/A1Z Specifications
- Product attributes
- Attribute value
- Manufacturer:
- NXP Semiconductors
- Series:
- -
- Package/Case:
- 25-UFBGA, WLCSP
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Active
- Type:
- RFID Reader
- Frequency:
- 13.56MHz
- Standards:
- ISO 14443
- Interface:
- I2C, SPI
- Voltage - Supply:
- 1.7V ~ 3.6V
- Operating Temperature:
- -40°C ~ 85°C
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Surface Mount
- Supplier Device Package:
- 25-WLCSP (2.51x2.51)
NHS3152UK/A1Z FAQ
1.How can I place an order for NHS3152UK/A1Z through Aetrix?
Please submit a Request for Quotation (RFQ) for NHS3152UK/A1Z on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for NHS3152UK/A1Z reliable?
The price and inventory of NHS3152UK/A1Z are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for NHS3152UK/A1Z is usually 5 days.
3.What payment methods are accepted for NHS3152UK/A1Z?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for NHS3152UK/A1Z transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for NHS3152UK/A1Z?
NHS3152UK/A1Z orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your NHS3152UK/A1Z order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for NHS3152UK/A1Z?
For technical support, including NHS3152UK/A1Z datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your NHS3152UK/A1Z requirements.
6.How does Aetrix verify that NHS3152UK/A1Z is sourced from the original manufacturer or authorized distributors?
All NHS3152UK/A1Z products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that NHS3152UK/A1Z meets industry standards.
7.What is the process for return or replacement of NHS3152UK/A1Z?
All NHS3152UK/A1Z units undergo pre-shipment inspection (PSI). If there is an issue with NHS3152UK/A1Z, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The NHS3152UK/A1Z part is unused and in its original packaging.
Return procedure for NHS3152UK/A1Z:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
NHS3152UK/A1Z Tags

-
SL2S2602FTBX
NXP Semiconductors

-
ST25DV04K-IER6S3
STMicroelectronics

-
ST25DV04K-IER6C3
STMicroelectronics

-
LXMSJZNCMD-217
Murata Electronics

-
NT3H2111W0FTTJ
NXP Semiconductors

-
NT3H2111W0FHKH
NXP Semiconductors

-
M24LR04E-RMC6T/2
STMicroelectronics

-
ST25DV04KC-JF6D3
STMicroelectronics

-
ST25DV64KC-IE6S3
STMicroelectronics
-
ST25DV64K-IER6T3
STMicroelectronics

-
NT3H2211W0FTTJ
NXP Semiconductors

-
NT3H2211W0FHKH
NXP Semiconductors
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…

