Diodes Incorporated P6KE200A-T
- Part No.:
- P6KE200A-T
- Manufacturer:
- Diodes Incorporated
- Category:
- TVS Diodes
- Package:
- DO-204AC, DO-15, Axial
- Datasheet:
-
P6KE200A-T.pdf
- Description:
- TVS DIODE 171VWM 274VC DO15
- Quantity:
- Payment:

- Shipping:

Inventory:3,073
Please send an inquiry. Send us your inquiry, and we will respond immediately.
Product details
Overview
P6KE200A-T from Diodes Incorporated is a unidirectional 600W transient voltage suppressor (TVS) diode designed for primary overvoltage protection in DC power lines and signal interfaces. It features a 171–210 V reverse standoff voltage range (VRWM), 274 V maximum clamping voltage at 2.2 A peak pulse current, and DO-15 glass-passivated package. Used in industrial power supplies and telecom line cards to absorb lightning-induced surges.
For engineers reviewing the P6KE200A-T datasheet, P6KE200A-T pinout, P6KE200A-T application, or P6KE200A-T equivalent, key selection criteria include clamping voltage margin relative to protected IC VCC rails, 1.0 ms pulse waveform compliance, thermal derating above +25°C ambient, and unidirectional polarity alignment with DC bias direction.
Technical Context
This TVS operates as a voltage-clamped shunt protector: under normal conditions it presents <5 µA leakage at 171 V; when transient voltage exceeds 190 V (min breakdown), it avalanches rapidly (<1 ns response) to clamp the line at ≤274 V. Its 600 W peak pulse rating applies to a single 1.0 ms 10/1000 µs waveform per IEC 61000-4-5.
The device uses a glass-passivated silicon junction for stable breakdown characteristics and long-term reliability. Thermal resistance from junction to ambient is 75 °C/W, requiring PCB copper land area (≥40 mm²) and lead length control (9.5 mm) to sustain 5.0 W steady-state dissipation at TL = +75°C.
Key Specifications
| Parameter | Value and Actual Design Meaning |
|---|---|
| Peak Pulse Power | 600 W - Sustains one 1.0 ms 10/1000 µs surge without failure per IEC 61000-4-5 Level 4. |
| Reverse Standoff Voltage | 171–210 V - Maximum continuous DC or RMS voltage before significant leakage; sets minimum operating rail margin. |
| Breakdown Voltage | 190 V min @ 1 mA - Confirmed avalanche initiation point; ensures reliable turn-on before downstream IC damage. |
| Clamping Voltage | 274 V max @ 2.2 A - Actual voltage seen by protected circuit during surge; defines safe headroom for 240 VAC-derived rails. |
| Leakage Current | ≤5.0 µA @ 171 V - Negligible standby power loss and minimal impact on high-impedance sensing nodes. |
| Package | DO-15 - Axial-leaded plastic case rated UL 94V-0; enables manual soldering and wave-solder compatibility. |
Pinout & Package
DO-15 package: axial-leaded, molded plastic body with cathode band marking. Dimensions: length 25.4 mm (min), body diameter 5.5–7.62 mm, lead diameter 0.686–0.889 mm, lead spacing 2.6–3.6 mm.
| Pin/Terminal | Circuit Role | Design Meaning |
|---|---|---|
| Anode | Low-side reference terminal | Connected to ground or lowest potential node; defines unidirectional conduction path from cathode to anode during surge. |
| Cathode | High-side surge input terminal | Marked with band; connects to protected line; conducts avalanche current to anode when line voltage exceeds VRWM. |
Key Features
| Feature | Design Value |
|---|---|
| 600 W peak pulse rating | Enables robust protection against IEC 61000-4-5 4 kV/2 Ω surges on 240 VAC-derived DC buses. |
| Glass-passivated die construction | Ensures stable breakdown voltage over temperature (-55°C to +175°C) and long-term reliability in humid environments. |
| Fast response time (<1 ns) | Clamps transients before sensitive downstream components (e.g., MOSFET gate drivers, MCU I/O) experience overvoltage stress. |
| RoHS-compliant lead finish | Meets EU Directive 2011/65/EU with full exemption documentation; supports lead-free reflow and hand-soldering processes. |
Applications
| Industrial Power Supply Input Protection | Telecom Line Card Surge Suppression |
|---|---|
Use Scenario: 240 VAC rectified and filtered DC bus feeding isolated DC/DC converters in factory automation controllers. IC Role / Device Role / Timing Role: Unidirectional TVS placed between +BUS and GND to clamp lightning-induced common-mode surges entering via AC input. Use Value: Limits transient voltage to ≤274 V, preserving 400 V-rated bulk capacitors and preventing MOSFET avalanche failure in primary-side switches. |
Use Scenario: -48 VDC power feed to DSLAM line cards exposed to induced surges from nearby lightning strikes on telephone cables. IC Role / Device Role / Timing Role: Shunt protector on -48 V rail upstream of DC/DC regulators and line interface ICs. Use Value: Absorbs 600 W surge energy within 1.0 ms, maintaining rail integrity below -55 V to avoid regulator shutdown and data corruption. |
| Automotive Body Control Module (BCM) Power Input | Renewable Energy Inverter DC Link Protection |
Use Scenario: 12 V battery-fed BCM with CAN/LIN interfaces subject to load dump (ISO 7637-2 Pulse 5a) and jump-start transients. IC Role / Device Role / Timing Role: Primary clamping device on main VBAT input, coordinated with upstream fuse and secondary LC filtering. Use Value: Clamps 120 V transients to ≤274 V with 2.2 A peak current, allowing downstream LDOs and microcontrollers to remain operational. |
Use Scenario: 600 V DC link in solar string inverters where PV array surges couple into DC bus during grid faults or lightning events. IC Role / Device Role / Timing Role: Parallel-mounted TVS across DC+ and DC− near inverter bridge to limit overvoltage during fast-rising transients. Use Value: Provides 600 W pulse handling at 200 V nominal, enabling system-level coordination with MOVs and crowbar circuits for multi-stage protection. |
Equivalent & Alternatives
The following parts are listed as comparable options for similar transient suppression applications.
| Alternative Part | Technical Difference | Application Difference | Selection Advice |
|---|---|---|---|
| SMBJ200A-T | Same 200 V standoff, but SMB package (surface-mount); 600 W rating at 1.0 ms; lower RθJA (50 °C/W vs. 75 °C/W). | Requires PCB real estate for SMT placement; better thermal performance in compact layouts; no axial lead bending needed. | Select for automated assembly, space-constrained designs, or higher board density where DO-15 leads pose routing challenges. |
| P6KE200CA-T | Bidirectional version; identical VRWM (171–210 V), same clamping (274 V), but symmetrical breakdown in both polarities. | Used in AC-coupled or floating signal lines (e.g., RS-485, CAN bus) where polarity reversal or differential surges occur. | Select only when protecting bidirectional signals or AC-powered circuits; unidirectional P6KE200A-T is preferred for DC rails to avoid unnecessary leakage. |
Compared with SMBJ200A-T, P6KE200A-T offers easier manual prototyping and legacy through-hole compatibility but requires more board area and has higher thermal resistance; compared with P6KE200CA-T, it provides lower leakage and tighter clamping control in fixed-polarity DC systems.
Availability
P6KE200A-T is available at Aetrix Electronics and suitable for industrial power supply input protection, telecom line card surge suppression, and automotive body control module (BCM) power input requiring stable component supply despite its obsolete status.
Supply support for P6KE200A-T includes scheduled delivery planning, volume procurement assistance, BOM continuity management, traceable sourcing, and lifecycle availability coordination for OEM customers, industrial embedded developers, connected-device designers, and electronics production programs.
Manufacturer
Diodes Incorporated is a global manufacturer of discrete semiconductors and analog ICs, headquartered in Plano, Texas, with design, manufacturing, and sales operations across Asia, Europe, and North America.
P6KE200A-T belongs to the P6KE series of 600 W axial-leaded TVS diodes, engineered for cost-effective, high-energy transient suppression in industrial, telecom, and automotive power systems where DO-15 form factor and proven field reliability are prioritized.
FAQ
Is P6KE200A-T still in active production?
No - Diodes Incorporated has officially discontinued the P6KE200A-T and marked it as obsolete per DS21502 Rev. 20-4 (August 2024). Aetrix Electronics maintains limited legacy stock with full traceability and offers engineering support for last-time buys and cross-reference alternatives.
What is the maximum clamping voltage for P6KE200A-T at 1.0 A surge current?
Per the datasheet's electrical characteristics table, the maximum clamping voltage VC is specified at IPP = 2.2 A (not 1.0 A). Extrapolation is not valid; actual clamping at 1.0 A would be lower than 274 V but is not characterized or guaranteed. Design must use the rated 2.2 A condition.
Can P6KE200A-T be used in place of a bidirectional TVS like P6KE200CA-T?
No - P6KE200A-T is unidirectional and will conduct continuously if reverse-biased beyond its breakdown voltage. Substituting it for P6KE200CA-T in AC or floating signal paths risks catastrophic failure, excessive leakage, or incorrect clamping behavior during negative transients.
What is the recommended PCB pad layout for DO-15 mounting to ensure thermal performance?
Diodes specifies a 40 mm² copper land area with 9.5 mm lead length for 5.0 W steady-state dissipation. Use ≥2 oz copper, thermal vias under pads, and minimize trace length between anode/cathode pads and ground/power planes to maintain RθJA ≤75 °C/W.
P6KE200A-T Specifications
- Product attributes
- Attribute value
- Manufacturer:
- Diodes Incorporated
- Package/Case:
- DO-204AC, DO-15, Axial
- Series:
- -
- Packaging:
- Tape & Reel (TR)
- Product Status:
- Obsolete
- Type:
- Zener
- Unidirectional Channels:
- 1
- Bidirectional Channels:
- -
- Voltage - Reverse Standoff (Typ):
- 171V
- Voltage - Breakdown (Min):
- 190V
- Voltage - Clamping (Max) @ Ipp:
- 274V
- Current - Peak Pulse (10/1000µs):
- 2.2A
- Power - Peak Pulse:
- 600W
- Power Line Protection:
- No
- Applications:
- General Purpose
- Capacitance @ Frequency:
- -
- Operating Temperature:
- -55°C ~ 175°C (TJ)
- Grade:
- -
- Qualification:
- -
- Mounting Type:
- Through Hole
- Supplier Device Package:
- DO-15
P6KE200A-T FAQ
1.How can I place an order for P6KE200A-T through Aetrix?
Please submit a Request for Quotation (RFQ) for P6KE200A-T on Aetrix. Our sales agent will provide a competitive quotation and guide you through the order confirmation once you accept the terms.
2.Are the price and stock information for P6KE200A-T reliable?
The price and inventory of P6KE200A-T are updated periodically and may fluctuate due to market conditions. Stock and pricing data are typically refreshed every 24 hours. Quotation validity for P6KE200A-T is usually 5 days.
3.What payment methods are accepted for P6KE200A-T?
We accept Wire Transfer, PayPal, Credit Card, Western Union, MoneyGram, and Escrow for P6KE200A-T transactions.
Note: Certain payment methods may incur a processing fee.
4.How is shipping managed for P6KE200A-T?
P6KE200A-T orders can be shipped via leading logistics carriers, including DHL, UPS, FedEx, TNT, or Registered Mail.
Once your P6KE200A-T order is processed, you will receive an email with the shipment details and tracking number.
Note: Tracking information may take up to 24 hours to appear. Express delivery typically takes 3–5 business days.
5.How can I obtain technical support or documentation for P6KE200A-T?
For technical support, including P6KE200A-T datasheets, pinout diagrams, or application guidance, please contact our engineering support team. They can provide detailed documentation and assistance for your P6KE200A-T requirements.
6.How does Aetrix verify that P6KE200A-T is sourced from the original manufacturer or authorized distributors?
All P6KE200A-T products on Aetrix are procured from qualified distributors and authorized channels. Our dedicated quality assurance team conducts strict verification, including traceability checks and, if necessary, third-party testing. This ensures that P6KE200A-T meets industry standards.
7.What is the process for return or replacement of P6KE200A-T?
All P6KE200A-T units undergo pre-shipment inspection (PSI). If there is an issue with P6KE200A-T, returns or replacements are accepted under the following conditions:
1.Quantity discrepancies, incorrect items, or visible external defects (such as breakage or corrosion), acknowledged by Aetrix.
2.The issue is reported within 90 days of delivery.
3.The P6KE200A-T part is unused and in its original packaging.
Return procedure for P6KE200A-T:
1.Submit a request within 90 days.
2.Obtain a Return Material Authorization (RMA) from Aetrix.
P6KE200A-T Tags

-
ESD9B5.0ST5G
onsemi

-
DESD3V3E1BL-7B
Diodes Incorporated

-
ESD5Z3.3T1G
onsemi

-
D5V0H1B2LP-7B
Diodes Incorporated

-
D5V0P1B2LP-7B
Diodes Incorporated

-
DESD5V0U1BA-7
Diodes Incorporated

-
ESD5Z5.0T1G
onsemi

-
DESD5V0U1BB-7
Diodes Incorporated

-
D12V0L1B2LP-7B
Diodes Incorporated

-
PESD2V0Y1BSFYL
Nexperia USA Inc.

-
DF2S5M4CT,L3F
Toshiba Semiconductor and Storage

-
D5V0L1B2WS-7
Diodes Incorporated
Tech Hub
A practical engineering guide to 3.3V and 5V logic compatibility, input thresholds, resistor dividers, translator ICs, MOSFET level shifting, I2C pull-ups, timing limits and power-sequencing risks.
The 74HC595 uses push-pull logic outputs, while the TPIC6B595 uses 50 V open-drain DMOS sinks for higher-power loads. This guide compares timing, current limits, 3.3 V interfacing, load wiring, thermal…
The 74HC595 converts serial data into eight stable parallel outputs. This guide covers pin functions, shift and storage timing, OE and MR behavior, drive-current limits, cascading, voltage compatibilit…
A technical comparison of level-sensitive latches and edge-triggered flip-flops, covering timing windows, setup and hold limits, master–slave operation, time borrowing, race-through, HDL inference and…
A D latch stores one bit while Enable controls when data can pass. This reference covers gate-level operation, truth tables, transparency, setup and hold timing, LE versus OE, common ICs and practical …
An SR latch stores one bit through cross-coupled feedback. This engineering reference covers NOR and NAND implementations, truth tables, forbidden-state recovery, gated operation, switch debouncing, fa…
Latch circuits retain one bit through feedback. This technical reference covers SR and D latches, truth tables, transparency, timing limits, latch-versus-flip-flop behavior, applications and common log…
An engineering guide to LED driver operation, constant-current and constant-voltage outputs, linear and switching topologies, dimming, IC selection, calculations, replacement compatibility, and fault c…
Operational amplifier guide covering op amp basics, feedback, ideal vs real op amps, common configurations, buffer circuits, offset, bias current, gain-bandwidth, slew rate, rail-to-rail limits and sel…
Jumper cables guide covering safe connection order, red and black clamp placement, final ground connection, cable gauge, length, clamp quality, copper vs CCA cables, jump starter comparison and battery…